 WARNING: This gas appliance must not be con-

nected to a chimney flue servicing a solid fuel burning 

appliance.

 WARNING: Installation of this appliance should 

be done by a qualified service person well trained 

in the installation of such appliances. You will also 

need a building permit from your local Building and 

Safety Commissioner before installing this appli-

ance; otherwise your insurance co. may not cover 

this appliance.

WARNING: Young children should be carefully supervised when 

they are in the same room as the appliance. Toddlers, young chil-

dren, and others may be susceptible to accidental burns. A physical 

barrier is recommended if there are to be at-risk individuals in the 

house. To restrict access to a fireplace or stove, install an adjust-

able safety gate to keep toddlers, young children, and other at-risk 

individuals out of and away from hot surfaces.

 CAUTION: Do not connect appliance before pres-

sure testing gas piping. Damage to gas valve may 

result and an unsafe condition may be caused.

NOTICE: Decorative product not for use as a heating 

appliance.

INTRODUCTION

These fireplace models are vented gas fireplaces that use a millivolt 

gas control valve with a millivolt ignition system. 25" models have a 

5" B-vent and 24" models have a 4" B-vent. A properly sized B-Type 

venting system and listed type vent cap are not supplied but are 

required for proper operation. See venting instructions on Page 10.

These models are factory equipped for use with natural gas and must 

be converted when intended for use with propane/LP gas. Conver-

sion kits PCBM-324 and PCBM-325 may be purchased for simple 

conversion to propane/LP gas. See Accessories, Page 23.
BEFORE YOU BEGIN
Before beginning the installation of your appliance, read these in-

structions completely.

UNPACKING

The following items are packed inside the firebox. Remove before 

positioning firebox into framing.
•  Ceramic Log Pack - Shrink wrapped on cardboard
•  3 plastic bags containing volcanic stone, pan and ember materials
•  Rear Log (BRT2332TMN/BRT2532TMN Models Only). Remove 2 

plastic quick ties from around burner and grate

•  Grate Stand - Lift off of burner pan
Check all items for any shipping damage. If damaged, promptly 

inform dealer or distributor where you bought the product.
Retain these items for later installation.

The appliance and it’s individual shutoff valve must be disconnected 

from the gas supply piping system during any pressure testing of 

that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system 

by closing its individual manual shutoff valve during any pressure 

testing of the gas supply piping system at test pressures equal to or 

less than 1/2 psig (3.5 kPa).
For the purpose of input adjustment two pressure taps (for IN and 

OUT pressures) are provided on the gas control valve for test gauge 

connections to the appliance.
This fireplace may not be installed in manufactured (mobile) hous-

ing constructed to HUD standards. The fireplace may be installed in 

aftermarket, non-HUD manufactured housing provided its installation 

complies with State and Local Codes and in the absence of these 

codes complies with the National Fuel Gas Code ANSIZ223.1 NFPA 54..

CODES AND STANDARDS

These fireplaces comply with National Safety Standards and are 

tested and listed by PFS Corporation (Report No. F09-157) to ANSI 

Z21.50 (in Canada, CSA-2.22) in both USA and Canada, as vented 

gas fireplaces. The installation must conform to local codes or, 

in the absence of local codes, with the National Fuel Gas Code, 

ANSI Z223.1/NFPA 54—latest edition (In Canada, the current CAN/

CGA-B149.1 installation code). The fireplace, when installed, must 

be electrically grounded and wired in accordance with local codes 

or, in the absence of local codes, with the National Electrical Code, 

ANSI/NFPA 70—latest edition, or the Canadian Electrical Code, CSA 

C22.1—latest edition.

These appliances comply with CSA P.4.1-2015 “Testing Method for 

Measuring Annual Fireplace Efficiency. P4 (EnerGuide) is a measure-

ment of the Canadian Office of Energy Efficiency. 

Based on CSA P.4.1-2015

This INNOVATIVE HEARTH PRODUCTS (IHP) appliance and its ap-

proved components are safe when installed according to this instal-

lation manual and are operated as recommended by IHP. Using any 

component fon IHP approved and tested for use with this appliance 

MAY CAUSE A FIRE HAZARD!
The IHP warranty will be voided by, and IHP disclaims any respon-

sibility for the following actions:
A)  Modification of the appliance or any of the components.
B)  Use of any component part not approved by IHP in combination 

with this appliance.

C)  Installation and/or operation in a manner other than instructed 

in this manual.

D)  The burning of anything other than the type of gas approved for 

use in this gas appliance.

Summary of Contents for BRT2032TMN

Page 1: ...I VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchez aucaninterrupteur Nepasvousservir des t l phones se trouvant dans le b timent o vous trouvez Sortez imm diatement de b timen...

Page 2: ...so contains information that will enable you to obtain replacement parts or optional accessory items when needed Keep it with your other important papers State of Massachusetts The installation must b...

Page 3: ...he fireplace in high traffic areas in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Fireplace wi...

Page 4: ...ater installation The appliance and it s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 p...

Page 5: ...PROPANE LP Max Input Rating 15 000 Btu Hr 25 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13...

Page 6: ...d or at a premium and since the space required to enclose the appliance would be located beyond an outside wall this would also reduce the cutting of joists roof rafters and such Check local codes for...

Page 7: ...ling 0 Clearance Ceiling 1 2 5 cm Min Clearance to B Vent s Outer Pipe Required Air Spaces are Indicated with an Do Not Pack with Insulation or Any Other Material DO NOT BLOCK OR OBSTRUCT OPENINGS 0 C...

Page 8: ...o cover any openings Prepare the incom ing gas line with Teflon tape or pipe joint compound and hookup incoming gas line to flexible gas line PRE INSTALLATION PREPARATION Continued NOTE If 1 2 NPT bla...

Page 9: ...uirements are met Install this appliance in accordance with Massachusetts Rules and Regulations 248 C M R Sections 4 00 through 8 00 Installation and repair must be done by a plumber or gas fitter lic...

Page 10: ...lateral length must exceed 75 then the system must be sized in accordance with the Category I venting tables Example 2 shows a multiple offset each at 45 of inclination Multiple offsets are permitted...

Page 11: ...8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Ove...

Page 12: ...e s gas sup ply system You may consider installing an extra gas shutoff valve outside the appliance s enclosure check with local codes where it can be accessed more conveniently with a key through a w...

Page 13: ...nstallation is completed After ensuring that the gas valve is on apply a non corrosive leak detection solution to all connections and joints If bubbles appear leaks can be detected and corrected Do no...

Page 14: ...nder the lower grate members to allow air to flow see Figure 21 LOG PLACEMENT FOR BRT2032TMN MODEL 1 Place front log onto front of grate sliding log all the way forward against grate fingers see Figur...

Page 15: ...top of log 4 into notch on log 1 Rest log 4 on the center of grate as shown in Figure 26 5 Place top of log 5 into notch on top right of log 1 see Figure 26 Rest log 5 between two middle grate fingers...

Page 16: ...ge of firebox opening 4 Tilt door assembly fully vertical until outer pivot pin snaps into mounting hole in upper spring clip see Figure 30 5 Once top and bottom pins are secured unfold door into clos...

Page 17: ...ly Opened Door Figure 32 Removing Glass Doors Spring Clip Press Spring Clip to Release Pivot Pin Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track Pivot Plate Fold Bi Fold D...

Page 18: ...ndicator Gas Control Knob Pilot Adjustment Screw LIGHTING INSTRUCTIONS NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be prese...

Page 19: ...l knob to ON position Slide the selector switch to the REMOTE position NOTE Burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn burner on an...

Page 20: ...ce off see To Turn Off Gas to Appliance Page 19 see Troubleshooting Page 21 Figure 36 Typical Flame Pattern BRT2332TMN BRT2532TMN Models BRT2032TMN Model WARNING Installation and repair should be done...

Page 21: ...ossible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician replace pilot line 7 Replace regulator valve see Accessories Page 23 1 Check wiring...

Page 22: ...tween control valve and burner 2 Gas leak See Warning statement at top of Page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive...

Page 23: ...ete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time...

Page 24: ...ces us com 126745 01E 24 PARTS MODEL BRT2032TMN 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 36 14 12 13 23 16 31 32 20 32 38 39 40 40 4 34 35 21 17 8 10 18 5 5 2 22 1 3 37 42 11 11 9 CATALOG NO MODEL F...

Page 25: ...21 RP108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 J4373 Grate Assembly 1 24 J4308 Burner Assembly see Page 30 1 25 J6845 Gas Control Valve Natural Gas SIT 1 J6846 Gas Control Valve Pro...

Page 26: ...6 PARTS BRT2332TMN AND BRT2532TMN MODELS 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 18 14 12 13 23 10 36 9 36 35 16 31 32 20 32 38 39 40 40 4 34 21 17 8 46 45 44 2 22 1 3 44 11 37 42 5 5 CATALOG NO MO...

Page 27: ...108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 J4299 Grate Assembly 1 24 J4236 Burner Assembly see Page 30 1 25 J6845 Gas Control Valve Natural Gas SIT 1 J6846 Gas Control Valve Propane...

Page 28: ...2 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on Page 23 of this manual KEY NO PART NO...

Page 29: ...4 5 KEY NO PART NO DESCRIPTION QTY J4307 Log Set 1 J4339 Rear Log 1 2 J4338 Front Right Log 1 3 J4245 Front Left Log 1 4 J4244 Top Y Log 1 5 J4242 Top Log 1 WIRING DIAGRAM DO NOT CONNECT RED REPLACE F...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 32: ...ts Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126745 01 Rev E 02 2018 1769 East Lawrence Street Russellville AL 35654 SuperiorFi...

Reviews: