Superior BRT2032TMN Installation And Operation Instructions Manual Download Page 1

P126745-01

Installation and Operation Instructions

B-Vent Gas Decorative Fireplace

Models

P/N 126745-01   Rev. E   02/2018

BRT2032TMN   BRT2332TMN   BRT2532TMN

C

US

Report No. F09-157

 -  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use 

any phone in your building. 

•  Leave the building immediately.

•  Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instruc-

tions. 

•  If you cannot reach your gas supplier, call the 

fire department.

 -  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could 

result in serious injury, death, or property damage.

        AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION

Le non-respect Des avertissements de sécurité 

pourrait d’entraîner des blessures graves, la mort 

ou des dommages matériels.

 -  Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

 -  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir 

des téléphones se trouvant dans le bâtiment où 

vous trouvez. 

•  Sortez immédiatement de bâtiment.

• Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

  -    L’installation et l’entretien doivent être assurés par 

un installateur ou un service d’entretien qualifié 

ou par le fournisseur de gaz.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future 

reference.

Installateur : Laissez cette notice avec l’appareil.

Consommateur : Conservez cette notice pour 

consultation ultérieure.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) 

or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit 

is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements 

locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque 

signalétique.  Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.

Summary of Contents for BRT2032TMN

Page 1: ...I VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchez aucaninterrupteur Nepasvousservir des t l phones se trouvant dans le b timent o vous trouvez Sortez imm diatement de b timen...

Page 2: ...so contains information that will enable you to obtain replacement parts or optional accessory items when needed Keep it with your other important papers State of Massachusetts The installation must b...

Page 3: ...he fireplace in high traffic areas in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Fireplace wi...

Page 4: ...ater installation The appliance and it s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 p...

Page 5: ...PROPANE LP Max Input Rating 15 000 Btu Hr 25 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13...

Page 6: ...d or at a premium and since the space required to enclose the appliance would be located beyond an outside wall this would also reduce the cutting of joists roof rafters and such Check local codes for...

Page 7: ...ling 0 Clearance Ceiling 1 2 5 cm Min Clearance to B Vent s Outer Pipe Required Air Spaces are Indicated with an Do Not Pack with Insulation or Any Other Material DO NOT BLOCK OR OBSTRUCT OPENINGS 0 C...

Page 8: ...o cover any openings Prepare the incom ing gas line with Teflon tape or pipe joint compound and hookup incoming gas line to flexible gas line PRE INSTALLATION PREPARATION Continued NOTE If 1 2 NPT bla...

Page 9: ...uirements are met Install this appliance in accordance with Massachusetts Rules and Regulations 248 C M R Sections 4 00 through 8 00 Installation and repair must be done by a plumber or gas fitter lic...

Page 10: ...lateral length must exceed 75 then the system must be sized in accordance with the Category I venting tables Example 2 shows a multiple offset each at 45 of inclination Multiple offsets are permitted...

Page 11: ...8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Ove...

Page 12: ...e s gas sup ply system You may consider installing an extra gas shutoff valve outside the appliance s enclosure check with local codes where it can be accessed more conveniently with a key through a w...

Page 13: ...nstallation is completed After ensuring that the gas valve is on apply a non corrosive leak detection solution to all connections and joints If bubbles appear leaks can be detected and corrected Do no...

Page 14: ...nder the lower grate members to allow air to flow see Figure 21 LOG PLACEMENT FOR BRT2032TMN MODEL 1 Place front log onto front of grate sliding log all the way forward against grate fingers see Figur...

Page 15: ...top of log 4 into notch on log 1 Rest log 4 on the center of grate as shown in Figure 26 5 Place top of log 5 into notch on top right of log 1 see Figure 26 Rest log 5 between two middle grate fingers...

Page 16: ...ge of firebox opening 4 Tilt door assembly fully vertical until outer pivot pin snaps into mounting hole in upper spring clip see Figure 30 5 Once top and bottom pins are secured unfold door into clos...

Page 17: ...ly Opened Door Figure 32 Removing Glass Doors Spring Clip Press Spring Clip to Release Pivot Pin Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track Pivot Plate Fold Bi Fold D...

Page 18: ...ndicator Gas Control Knob Pilot Adjustment Screw LIGHTING INSTRUCTIONS NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be prese...

Page 19: ...l knob to ON position Slide the selector switch to the REMOTE position NOTE Burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn burner on an...

Page 20: ...ce off see To Turn Off Gas to Appliance Page 19 see Troubleshooting Page 21 Figure 36 Typical Flame Pattern BRT2332TMN BRT2532TMN Models BRT2032TMN Model WARNING Installation and repair should be done...

Page 21: ...ossible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician replace pilot line 7 Replace regulator valve see Accessories Page 23 1 Check wiring...

Page 22: ...tween control valve and burner 2 Gas leak See Warning statement at top of Page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive...

Page 23: ...ete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time...

Page 24: ...ces us com 126745 01E 24 PARTS MODEL BRT2032TMN 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 36 14 12 13 23 16 31 32 20 32 38 39 40 40 4 34 35 21 17 8 10 18 5 5 2 22 1 3 37 42 11 11 9 CATALOG NO MODEL F...

Page 25: ...21 RP108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 J4373 Grate Assembly 1 24 J4308 Burner Assembly see Page 30 1 25 J6845 Gas Control Valve Natural Gas SIT 1 J6846 Gas Control Valve Pro...

Page 26: ...6 PARTS BRT2332TMN AND BRT2532TMN MODELS 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 18 14 12 13 23 10 36 9 36 35 16 31 32 20 32 38 39 40 40 4 34 21 17 8 46 45 44 2 22 1 3 44 11 37 42 5 5 CATALOG NO MO...

Page 27: ...108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 J4299 Grate Assembly 1 24 J4236 Burner Assembly see Page 30 1 25 J6845 Gas Control Valve Natural Gas SIT 1 J6846 Gas Control Valve Propane...

Page 28: ...2 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on Page 23 of this manual KEY NO PART NO...

Page 29: ...4 5 KEY NO PART NO DESCRIPTION QTY J4307 Log Set 1 J4339 Rear Log 1 2 J4338 Front Right Log 1 3 J4245 Front Left Log 1 4 J4244 Top Y Log 1 5 J4242 Top Log 1 WIRING DIAGRAM DO NOT CONNECT RED REPLACE F...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 32: ...ts Consult your local distributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126745 01 Rev E 02 2018 1769 East Lawrence Street Russellville AL 35654 SuperiorFi...

Reviews: