background image

Superior Signal Company LLC 

 

AccuTrak

 ®

 VPE-

1000 User’s Manual

 © 2015 

17

 

Charting your results  

Ultrasound will be produced differently for all types of systems.  It may be strong 
on  one  side  of  a  bearing  shaft,  and  weak  on  the  other,  depending  upon  the 
unique wear patterns. Therefore it is very important to mark the test point, so that 
future readings can be taken from the exact same position.   Doing the same test 
with the sensitivity set differently can completely change the results, therefore it 
is extremely important to keep track of the instruments settings for future tests to 
be valid. 

A  chart  is  provided  in  the  back  of  this  manual  to  help  you  keep  track  of  your 
results.    This  can  help  you  easily  see  the  changes  or  inconsistencies  which 
indicate  problems.    The  chart  also  acts  as  a  report  card  and  helps  you  give  a 
much more accurate diagnosis of system health.   

Keep  this  information  in  your  files,  or  tagged  on  the  equipment  itself.    When 
returning  to  the  same  equipment,  perhaps  several  months  or  even  years  later, 
you have the information you need to make a decision as to the degree of wear 
in a particular piece of equipment. 

It is worth while to show this information to your customers.   Letting them know 
what  is going on will help build your reputation, credibility, and  make you more 
profits  in  the  process.    Maintenance  agreements  are  much  easier  to  sell  when 
they  include  AccuTrak

®

  testing.    More  scheduled  repairs  and  less  emergency 

repairs keeps your business under control, as well as your clients temper. 

 

Vibration 

Vibration, misalignment, or moving machinery which is not properly balanced can 
be  deadly  to  a  system.    These  things  can  cause  leaks,  and  excessive  wear 
bringing the life of any system to an early demise. 

All these problems have a common warning signal: 

increased ultrasonic energy

.  

This  ultrasonic  energy  is  generated  from  the  friction  associated  with  these 
problems,  and  can  be  detected  with  the  AccuTrak

®

.    With  experience,  you  will 

know what readings are good, and which are bad for the most common types of 
equipment you work on.   

Example:    If  you  are  responsible  for  maintaining  the  A/C  units  in  a  large 
residential  area  such  as  an  apartment  complex,  where  all  residences  use  the 
same cooling unit.  After testing a sample of compressors, you soon will be able 
to easily determine what readings are normal or abnormal for a particular model.   

Summary of Contents for AccuTrak VPE-1000

Page 1: ...Model VPE 1000 USER S MANUAL www SuperiorSignal com Superior Signal Company LLC 2015...

Page 2: ...Display 10 Hidden MODE Options 10 APPLICATIONS OVERVIEW 11 1 AIRBORNE APPLICATIONS EXTERNAL SOUNDS 11 Leaks 11 Methods of reducing background noise interference 12 Recording overall system noise 13 2...

Page 3: ...can produce such accurate readings and consistent results in repeatable tests The internal signal processing is performed by a patented process with additional patents pending This circuitry assures...

Page 4: ...ows relative strength of detected signal in a bargraph format D Power button Turns the instrument on or off E Alphanumeric Display A N D Level Mode Indicator Displays active mode current mode setting...

Page 5: ...ors the end closest to you there is a sliding panel Apply minimal pressure to the center of the panel and slide it towards you exposing the battery compartment Install a fresh new 9 Volt Alkaline batt...

Page 6: ...d present in the test area and the LED bargraph meter will display the strength of the corresponding signal The highest LED will hold its place for 5 seconds before resetting its position This will he...

Page 7: ...ng in bearings 4 The VPE 1000 always defaults back to Sensitivity as the active mode therefore if your readings are off the scale simply press the to reduce the reading to within the range of the inst...

Page 8: ...e flowing the flow is normally laminar which means that a given layer of gas does not mix with layers above it or below it This condition happens in a straight long tube when the velocity of the fluid...

Page 9: ...on off button D once to turn the unit on depress it again to turn the unit off Depending on whether you are in contact or airborne mode you will immediately begin to hear the translated ultrasonic si...

Page 10: ...e pressing the MODE button once will put the AccuTrak in the Volume Adjust Mode The alphanumeric display will read Vol as long as the MODE button is pressed When released it will show V000 indicating...

Page 11: ...essing the or buttons it will scroll through the display options which are as follows Cont Continuous the A N D will show the level of the signal in real time Peak Peak Hold the A N D will hold the hi...

Page 12: ...duce the sensitivity until only the first one or two lights are lit on the LED bargraph meter Check around fittings flanges and all other suspected areas If at anytime the display is at maximum due to...

Page 13: ...f how the direct translation process of the AccuTrak helps you to distinguish the difference between the two signals Practice listening to different components of your system this will help you to ide...

Page 14: ...ak readings were taken Although the AccuTrak will only record the ultrasonic range of a noisy system this part of the sound will increase in proportion to the sonic part the customer is hearing and co...

Page 15: ...has accumulated at the trap The steam trap then will open to purge the condensate while retaining the steam for maximum efficiency Problems arise when a malfunctioning steam trap fails in either the o...

Page 16: ...alve ball needle gate or any type of valve which may be leaking internally Are valves functioning properly When in the closed position are they truly closed Is the TXV clogged or iced Restrictions or...

Page 17: ...r results To take a reading on a mechanical system such as a bearing or gear box you must use the touch probe attachment Touch the end of the probe to the outer housing of the gear box or bearing maki...

Page 18: ...the degree of wear in a particular piece of equipment It is worth while to show this information to your customers Letting them know what is going on will help build your reputation credibility and ma...

Page 19: ...ll times Make certain the cord from the headphones is out of the way of any moving machine member Other Applications Use your imagination The AccuTrak is probably one of the most versatile test instru...

Page 20: ...s use the yellow waveguide to protect any fluid from entering the sensor Optional Sound Generator The ultrasonic sound generator is used to detect leaks in enclosures which are not under pressure This...

Page 21: ...and allows you to schedule the repair BEFORE this happens A significant increase in compressor noise indicates looseness wear or other serious problems AccuTrak helps prevent vibration caused leaks St...

Page 22: ...ironments When performing touch probe applications do not use excessive pressure on the item being tested Bent probes or cracked sensor housings are considered abuse and will not be covered under warr...

Page 23: ...s are at the sole discretion of Superior Signal Company LLC Maximum liability under any circumstance shall be limited to replacement of unsatisfactory product Recommendations and product information a...

Page 24: ...aveguide 11 Leak Detection 5 method outline 5 leaks 11 Quick Overview 5 modes selection 8 natural gas 7 Operation 8 Pneumatics and Hydraulics 19 roof leaks 19 Sensitivity Setting the sensitivity 9 Ser...

Page 25: ...Superior Signal Company LLC AccuTrak VPE 1000 User s Manual 2015 24...

Reviews: