superior fires ASABA CONTEMPORARY BLACK SLIMLINE CONVECTOR Installation & User'S Instructions Download Page 1

INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MODELS COVERED BY THESE INSTRUCTIONS

MARLFIELD SLIMLINE RADIANT 

F500384

KINLOCH SLIMLINE RADIANT 

F500385

CHEWTON GROVE BRASS SLIMLINE RADIANT 

F500386

CHEWTON GROVE BLACK SLIMLINE RADIANT 

F500550

CHEWTON GROVE CHROME SLIMLINE RADIANT  

F500551/2

ASABA CONTEMPORARY SLIMLINE CONVECTOR

F500388

ASABA CONTEMPORARY BLACK SLIMLINE CONVECTOR

F500556

ASABA GROVE BRASS SLIMLINE CONVECTOR 

F500557

ASABA GROVE BLACK SLIMLINE CONVECTOR 

F500558

ASABA GROVE CHROME SLIMLINE CONVECTOR 

F500389

ASABA ELEGANCE BRASS SLIMLINE CONVECTOR 

F500553

ASABA ELEGANCE BLACK SLIMLINE CONVECTOR 

F500555

ASABA ELEGANCE BRASS/BLK SLIMLINE CONVECTOR 

F500554

CHEWTON SOHO SLIMLINE RADIANT 

F500387

CHEWTON SOHO BLACK SLIMLINE RADIANT 

F500387

MARLFIELD SLIMLINE RADIANT TC

*

F500479

KINLOCH SLIMLINE RADIANT TC

*

F500480

CHEWTON GROVE SLIMLINE RADIANT TC

*

F500481

CHEWTON SOHO SLIMLINE RADIANT TC

*

F500482

*TC = ‘TOP CONTROL’ OR ‘SLIDE CONTROL’

RADIANT/CONVECTOR INSET GAS FIRE

Please  note  :  Except  where  otherwise  stated,  all  rights,  including

copyright in the text, images and layout of this booklet is owned by

Superior Fires Ltd.  You are not permitted to copy or adapt any of the

content without the prior written permission of Superior Fires Ltd. 

1

Revision C - 10/12

© 2012 Superior Fires Ltd.

MARLFIELD SLIMLINE RADIANT

KINLOCH SLIMLINE RADIANT

GB IE

BS 7977-1 : 2009

BS EN 509 : 2000

KM579168

Superior Fires

Christchurch, Dorset BH23 2BT

Tel: 01202 588 632     

Fax: 01202 499326

www.superiorfires.co.uk

e : [email protected]

IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE

CHEWTON GROVE SLIMLINE RADIANT

ASABA CONTEMPORARY SLIMLINE CONVECTOR

ASABA GROVE SLIMLINE CONVECTOR

ASABA ELEGANCE SLIMLINE CONVECTOR

CHEWTON     SOHO   SLIMLINE  RADIANT   

Summary of Contents for ASABA CONTEMPORARY BLACK SLIMLINE CONVECTOR

Page 1: ...SLIMLINE RADIANT TC F500479 KINLOCH SLIMLINE RADIANT TC F500480 CHEWTON GROVE SLIMLINE RADIANT TC F500481 CHEWTON SOHO SLIMLINE RADIANT TC F500482 TC TOP CONTROL OR SLIDE CONTROL RADIANT CONVECTOR IN...

Page 2: ...of this appliance This appliance is free from any asbestos material Refractories and fuel bed are constructed from ceramic fibre Remote control models These appliances features a battery operated cont...

Page 3: ...ident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared...

Page 4: ...ward projection does not exceed 100mm Any com bustible side walls must be at least 500mm to the side of the radiant heat source As with all heating appliances any decorations soft furnishings and wall...

Page 5: ...llation It is important that the sealing requirements of the appliance are met at all times and that the flue box is well sealed to any back or infill panel Note The DEPTH dimension is inclusive of an...

Page 6: ...M4 nyloc nut provided Affix the Slide control position marking sticker on the trim next to the control knob as shown in figure 16 Before installing the fire check the flue using a smoke pellet All of...

Page 7: ...to pull the appliance tightly against the fireplace opening Visually inspect the seal and reseat if necessary Do not cut off excess cable Surplus cable must not be cut off as it will be impossible to...

Page 8: ...es may be rotated for good viewing The fire features a twin spark ignition system to aid lighting Push the control knob in fully and turn anti clockwise through both of the SPARK positions keep ing fu...

Page 9: ...own and the pilot lit with a taper Light the fire on the HIGH setting To commission the appliance the operating pressure must be in accordance with the figures stated in section 2 0 of these instructi...

Page 10: ...g this time Advise that the fire is fitted with a spillage safety device O D S If the fire shuts down this system may be in operation If spillage is suspected SWITCH APPLIANCE OFF and call in the inst...

Page 11: ...hermocouple nut on the rear of the valve and the two securing screws and lifting away Remove the tubing nut from the valve end of the pilot pipe and blow through to dislodge any debris Clean the pilot...

Page 12: ...Blocked pilot clean out Excessive drafts in the room Excessive flue pull Fire is too close to an air vent Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will n...

Page 13: ...ns occur It is NOT a sub stitute for an independently mounted Carbon Monoxide detector This fire is supplied with a particular style of firefront Use of the firefront will ensure an adequate airflow u...

Page 14: ...s before repeating the ignition procedure To turn the main burner OFF whilst keeping the pilot flame lit turn the ignition control knob to the pilot position then only the pilot will remain lit To shu...

Page 15: ...ir sides as shown Place the rear row of four coals making sure that the flat sides are firmly against the brick panel and side cheeks as shown The coals must not be crammed together or inserted into t...

Page 16: ...with the pebbles supplied when assembled according to the instructions Never add to the fifteen pebbles or change them for a different type Never throw rubbish or other matter onto the fuel bed Due t...

Page 17: ...ved by using a damp cloth and mild household detergent Brass parts of the firefront may be cleaned using a suitable brass cleaner Replace the front centrally against the fire after cleaning Do not use...

Page 18: ...pilot 9055 Slide control models F730101 Gas valve Manual control models F730085 Gas valve Remote control models F730011 Gas valve Slide control models F730100 Injector Stereo 78 Manual Slide control m...

Page 19: ...ovement and development we hope therefore you will understand we must retain the right to amend details and or specifications without prior notice 7 F861083 GB IE Date of service Serviced by name GAS...