background image

SuperiorFireplaces.us.com

126595-01_J

7

FIREPLACE INSTALLATION

SELECTING LOCATION

To determine the safest and most efficient location for the fireplace, 

you must take into consideration the following guidelines:
1.  The location must allow for proper clearances (see Figures 4 and 

5).

2.  Consider a location where fireplace will not be affected by drafts, 

air conditioning ducts, windows or doors.

3.  A location that avoids cutting of joists or roof rafters will make 

installation easier.

4.  An outside air kit is available with this fireplace (see Optional 

Outside Air Kit on page 9).

MINIMUM CLEARANCE TO COMBUSTIBLES

Back and sides of fireplace  

 

1-

1

/

2

" (39 mm) min.

Ceiling  

 

42" (1067 mm) min.

Front of fireplace  

 

48" (1220 mm) min.

Floor**  

 

0" (0 mm) min.

Perpendicular wall to opening  

 

18" (458 mm) min.

36" Models  

 

12" (305 mm) min.

Top spacers  

 

0" (0 mm) min.

Mantel clearances  

 

see Mantels, page 8

Chimney outer pipe surface  

 

2" (51 mm) min.

* Not required at nailing flanges

** See step 2 of Framing

 WARNING: Do not pack required air spaces with 

insulation or other materials.

Minimum/Maximum Chimney Height for Residential Installation

Minimum height of chimney, measured from base of fireplace to flue 

gas outlet of termination, is 16 feet for straight flue or a flue with one 

elbow set. Maximum distance between elbows is 6 feet. For systems 

with two elbow sets, minimum height is 22 feet. Maximum height of 

any system is 50 feet. This measurement includes fireplace, chimney 

sections and height of termination assembly at level of the flue gas 

outlet (see Figure 15, page 12).

FRAMING

1.  Frame opening for fireplace using dimensions shown in Figures 4 

and 5.

2.  If fireplace is to be installed directly on carpeting, tile or any 

combustible material other than wood flooring, fireplace must 

be installed upon a metal or wood panel extending full width and 

depth of fireplace.

3.  Set fireplace directly in front of this opening and slide unit back 

until nailing flanges touch side framing.

4.  Check level of the fireplace and shim with sheet metal if necessary.
5.  Before securing fireplace to prepared framing, ember protector 

(provided) must be placed between hearth extension (not sup-

plied) and under bottom front edge of fireplace to protect against 

glowing embers falling through. If fireplace is to be installed on a 

raised platform, a Z-type ember protector (not supplied) must be 

fabricated to fit your required platform height. Ember protector 

should extend under fireplace a minimum of 1 

1

/

2

". Ember protector 

should be made of galvanized sheet metal (28 gauge minimum to 

prevent corrosion.

6.  Using screws or nails, secure fireplace to framing through flanges 

located on sides of fireplace.

45-

5

/

8

(1159 mm)

58-

1

/

8

"

(1477 mm)

67-

1

/

8

"

(1705 mm)

30-

1

/

8

"

(766 mm)

28-

1

/

4

(718 mm)

 

(36" Models)

51-

5

/

8

(1312 mm)

59-

3

/

4

(1518 mm)

(50" Models)

(36" Models)

(42" Models)

61

(1550 mm) - 

(36" Models)

65

(1651 mm) - 

(42" Models)

71

(1804 mm) - 

(50" Models)

86-

1

/

2

(2198 mm) - 

(36" Models)

Maintain 

1-

1

/

2

(39 mm)

Clearance at 

Sides and Back 

of Fireplace

1-

1

/

2

(39 mm)

Clearance 

Not Required at

Nailing Flanges

92

(2337 mm) - 

(42" Models)

100

(2540 mm) - 

(50" Models)

Figure 5 - Corner Installation

Figure 4 - Framing Dimensions

Summary of Contents for WRT6036IH

Page 1: ...vent free gas log heater approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before instal...

Page 2: ...anufacturer s instructions with the insert specifically state this fireplace has been tested for use with this insert FOR YOUR SAFETY Do not store or use gasoline or any other flammable vapors or liqu...

Page 3: ...king causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Early signs of carbon monoxidepoiso...

Page 4: ...20 1 4 515 mm Ref 14 1 2 369 mm 4 1 2 115 mm 10 1 2 267 mm 9 1 2 242 mm 3 1 2 89 mm 4 1 2 115 mm 45 1 8 1159 mm 36 915 mm 30 762 mm 49 1245 mm 67 1702 mm 11 280 mm 7 178 mm 61 1550 mm 1 26 mm 11 280 m...

Page 5: ...85 mm Ref 21 3 4 553 mm 15 3 4 400 mm 4 3 8 112 mm 10 1 2 267 mm 9 1 2 242 mm 3 1 2 89 mm 4 1 2 115 mm 51 1 8 1299 mm 42 1067 mm 30 762 mm 49 1245 mm 67 1702 mm 11 280 mm 7 178 mm 61 1550 mm 1 26 mm 1...

Page 6: ...7 178 mm 67 1702 mm 61 1550 mm 58 1474 mm 49 1245 mm 30 762 mm 9 1 2 242 mm 10 1 2 267 mm 13 331 mm 50 1270 mm 34 3 8 874 mm 38 1 2 978 mm 28 1 2 724 mm 17 5 8 448 mm 4 3 8 112 mm 19 1 4 489 mm 21 3...

Page 7: ...ight of termination assembly at level of the flue gas outlet see Figure 15 page 12 FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 4 and 5 2 If fireplace is to be installed dir...

Page 8: ...t Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS A mantel may be installed if desired see Figure 7 Woodwork su...

Page 9: ...Pipe Section 34 5 8 880 mm 48 12DM 48 12HT Pipe Section 46 5 8 1185 mm RLT 12D RLT 12HT Round Termina tion 7 3 4 197 mm STL 12D Square Chase Top with Slip Section 7 178 mm to 15 381 mm The lineal gain...

Page 10: ...t be secured with two screws on the outer pipe only see Figure 10 Do not penetrate the inner stainless Figure 11 Ceiling Support Pipe 12S 12DM 2 51 mm Min Straps Straps Straps Straps Detail A Return E...

Page 11: ...pacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame IMPORTANT NOTICE When penetrati...

Page 12: ...e Waterproof Caulk Storm Collar Flashing FLASHING INSTALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against r...

Page 13: ...ion be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stack...

Page 14: ...ination to Chase Top Flashing with Sheet Metal Screws Figure 23 Installing Termination Cap 1 Noncombustible Spacer Note Do Not Seal Ventilation Openings 1 Space Chase Facia 1 4 Screen Chase Top Sheet...

Page 15: ...h storm collar where chimney pierces opening in flash ing Caulk where storm collar touches outer chimney pipe see Figure 29 Figure 26 Constructing Chase Top Flashing As Required 2 Collar 16 1 2 Diamet...

Page 16: ...ch firebrick wall Angle the wall into the fireplace opening and into the slots on the side of the hearth Figure 32 then tilt the top of the panel toward the firebox sur round 3 Secure the firebrick wa...

Page 17: ...ure This will keep the mixture moist and it will not dry out before use 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mixture by moving trowel in the...

Page 18: ...eated WARNING Whenusingadecorativeventedgaslog the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position Gas line hook up shoul...

Page 19: ...TALLING GLASS DOORS Spring clips have been installed but some adjustments may be needed Install the doors using the following steps 1 With bifold doors completely folded insert bottom pivot pin into p...

Page 20: ...ould not be burned in this fireplace Always keep the fire well back from the doors and never allow flames to contact the glass WARNING Fireplaces equipped with glass doors should be operated only with...

Page 21: ...g agency for use with this fireplace may be used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in acco...

Page 22: ...ed for convenience 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 MODEL CATALOG NO WRT6036RS F0600 WRT6036IS F0601 WRT6036RH F0602 WRT6036IH F0603 WRT6042RS F0604 WRT6042IS F0605 WR...

Page 23: ...ace Top Assembly 50 1 10 J6997 Standoff 4 11 Fireplace Surround Assembly 1 12 J4362 Clearance Spacer 6 13 J5329 Fireplace Handle Bracket 4 14 J6900 Outside Air Cover Plate 2 15 J6934 Gas Conduit Cover...

Page 24: ...COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING 1 6 4 8 7 3 2 5 7 7 7 8 9 PARTS MODELS 36 42 AND 50 Picture may vary from actual Note See pages 25 and 26 for part numbers MODEL CATALOG NO WR...

Page 25: ...81 Rear Herringbone 50 Red 1 5 J6054 Right Stacked 36 Red 1 J6061 Right Herringbone 36 Red 1 J6462 Right Stacked 42 Red 1 J6468 Right Herringbone 42 Red 1 J6476 Right Stacked 50 Red 1 J6484 Right Herr...

Page 26: ...ar Herringbone 50 Ivory 1 5 J6055 Right Stacked 36 Ivory 1 J6062 Right Herringbone 36 Ivory 1 J6463 Right Stacked 42 Ivory 1 J6469 Right Herringbone 42 Ivory 1 J6477 Right Stacked 50 Ivory 1 J6485 Rig...

Page 27: ...i Temp Double Wall Pipe Snap Lock F0954 18 12HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0955 24 12HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0956 36 12HT 36 Section Hi Temp Double Wall P...

Page 28: ...creen F0960 RLT 12HT Hi Temp Round Top Termination with Louvered Screen FIRESTOP THIMBLE F0944 FST10 Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch...

Page 29: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...