background image

SuperiorFireplaces.us.com

126601-01_J

26

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns a. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our web 
site at SuperiorFireplaces.us.com.

REPLACEMENT PARTS

See Pages 20 to 23 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1769 East Lawrence Street

Russellville, AL 35654

Visit us at SuperiorFireplaces.us.com

IMPORTANT NOTICE

A manufactured shroud which has been approved by a 

national testing agency for use with this fireplace may 

be used if installed in accordance with the instructions 

by its manufacturer. A locally fabricated shroud may be 

used with IHP Shroud Leg Spacer Kit (SLK) in accor-

dance with instructions provided with the shroud.

NOTICE: The firebox canopy (hood) must not be mod-

ified or replaced with a canopy that may be provided 

with the unvented decorative room heater.

CAUTION: THE STRUCTURAL INTEGRITY OF THE 

MANUFACTURED HOME FLOOR, WALL, AND CEIL-

ING/ROOF MUST BE MAINTAINED.

 

 

WARNING: DO NOT INSTALL IN SLEEPING ROOM 

OF MOBILE HOMES.

Canadian code CAN/ULC-S610-M87 and other pertinent codes require stain-

less steel chimney for the installation of this fireplace. A Cold Air Climate Kit is 

also required in Canada and is recommended for cooler regions in the United 

States. Below, find a list of approved stainless steel parts.

Chimney Parts List for Canada

Catalog 

No.

Model 

No.

12" Hi-Temp  

Wood-burning Chimney

F0953

12-12HT

12" Section Double Wall Pipe

F0954

18-12HT

18" Section Double Wall Pipe

F0955

24-12HT

24" Section Double Wall Pipe

F0956

36-12HT

36" Section Double Wall Pipe

F0957

48-12HT*

48" Section Double Wall Pipe

F0958

30E-12HT

30" Offset and Return

F0959

12S-12HT

Chimney Support

F0960

RLT-12HT* Round Top w/ Louvers

F0961

AP-12HT

Anchor Plate/Collar Assembly (Masonry Fireplaces)

F0951

CAK-12

Cold Air Collar Kit

*When ordered alone, this part cannot ship via parcel delivery services.

IMPORTANT NOTICES - CANADA

Summary of Contents for WRT4536

Page 1: ...84 standards or for use with a vent free gas log heater approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such asthemunicipalbuildingdepartment firedepartment etc should...

Page 2: ...any other appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable materials on or near the app...

Page 3: ...thazard IMPORTANT See appendix A page 27 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOX...

Page 4: ...12 305 mm EACH SIDE MINIMUM 12 305 mm TOPERPENDICULAR SIDEWALL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE HEARTH EXTENSION 60 X 20 1524 mm x 508 mm OUTSIDE AIR 29 737 mm 22 1 2 572 mm 14...

Page 5: ...ACH SIDE MINIMUM 18 458 mm TOPERPENDICULAR SIDEWALL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE HEARTH EXTENSION 66 X 20 1677 mm x 508 mm OUTSIDE AIR 22 3 4 578 mm 30 1 2 775 mm 15 3 4 400...

Page 6: ...TERIAL ON FACE HEARTH EXTENSION 74 X 20 1880 mm x 508 mm OUTSIDE AIR 50 HEARTH 33 1 8 842 mm 23 1 4 591 mm 50 1270 mm 38 1 2 978 mm 28 1 2 724 mm 17 5 8 448 mm 4 3 8 112 mm 19 1 4 489 mm 24 610 mm 1 2...

Page 7: ...ight of termination assembly at level of the flue gas outlet see Figure 15 page 12 FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 4 and 5 2 If fireplace is to be installed dir...

Page 8: ...Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS A mantel may be installed if desired see Figure 7 Woodwork such as w...

Page 9: ...endently as the chimney is installed When connect ing chimney directly to the fireplace the inner flue pipe section must be installed first with the lanced side up The outer pipe section can then be i...

Page 10: ...t be secured with two screws on the outer pipe only see Figure 10 Do not penetrate the inner stainless Figure 11 Ceiling Support Pipe 12S 12DM CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFACTUREDHOMEF...

Page 11: ...e FST10 is required to avoid intrusion by insu lation and recommended to negotiate a joist Firestop Thimble FST10 Figure 14a Firestop Thimble PENETRATING ROOF To maintain a 1 36 Models or 2 42 50 Mode...

Page 12: ...used between the flashing and the roof The flashing must be secured to the roof using 8 x 3 4 screws and then sealed with roof coating to prevent leakage through the screw holes A roof coating must al...

Page 13: ...termination to another We suggest that terminations be separated at least 24 center to center and stacked at a vertical height difference of 18 see Figure 19 Note If a decorative shroud is to be inst...

Page 14: ...nd place flash ing over chase 4 Secure flashing through sides with 8 penny nails or sheet rock screws 5 Place galvanized sleeve through hole in flashing and around last section of chimney see Figure 2...

Page 15: ...lvanized steel over chimney outlet see Figure 29 6 Attach storm collar where chimney pierces opening in flash ing Caulk where storm collar touches outer chimney pipe see Figure 29 NONCHASE INSTALLATIO...

Page 16: ...ermine which is which match up the pattern on the rear panel with the left and right sides before installing the rear panel Make sure panel is center before continuing 5 Install the right and left ref...

Page 17: ...gure 34 Gas Line Access Side Firebrick Finished Side Brick with Access Hole Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1 2 Dowel Remove Knockout Gas line hook up should be done...

Page 18: ...doors completely folded insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door track Door is...

Page 19: ...ustion air and maintain safe temperatures in firebox IMPORTANT The glass must be allowed to warm slowly and evenly The tempered glass will withstand a gradual temperature rise to 550 F which is more t...

Page 20: ...laces us com 126601 01_J 20 PARTS 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 MODEL CATALOG NO WRT4536WS F0626 WRT4536WH F0627 WRT4542WS F0628 WRT4542WH F0629 WRT4550WS F0630 WRT...

Page 21: ...Pan 1 8 Top Insulation 1 9 Fireplace Top Assembly 36 1 Fireplace Top Assembly 42 1 Fireplace Top Assembly 50 1 10 J6997 Standoff 4 11 Fireplace Surround Assembly 1 12 J4362 Clearance Spacer 6 13 J532...

Page 22: ...the fireplace is placed in a permanent location WARNING LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING PARTS MODEL CATALOG NO WRT4536WS F0626 WRT4536WH F062...

Page 23: ...ite 1 7 J4466 Retainer Assy Ref Corner 2 1 F3278 45 series White Stacked Refractory Set 50 1 2 Refractory Hearth 50 Stk White 1 3 Refractory Rt 50 Stk White 1 4 Refractory Lt 50 Stk White 1 5 Refracto...

Page 24: ...tion Hi Temp Double Wall Pipe Snap Lock F0954 18 12HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0955 24 12HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0956 36 12HT 36 Section Hi Temp Double...

Page 25: ...and combustibles must not touch pipe Consult manual for clearance requirements Ensure proper connection WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for cleara...

Page 26: ...s fireplace may be used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions...

Page 27: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Page 28: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 32: ...6601 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: