background image

OK

Achieving Clean Burns

Check the exhaust in about 15 to 20 minutes 

(see below). Large amounts of smoke indicate 

an improper burn setting (either too high or too 

low). Adjust and recheck in 5 to 10 minutes.

FUEL

What does “Well-Seasoned” mean?

When a tree is cut down, the wood is green, 

full of sap and moisture. This moisture content 

can exceed 80%, which must be reduced to 

less than 20%. Wood properly seasoned is 

then capable of generating the heat the stove 

was designed to provide.
Green wood does not burn easily.  Attempting to 

burn green wood often results in a lot of smoke 

and very little fire. Time is the most important 

factor in seasoning wood.  Ideally the moisture 

content should be reduced to 11-20%.  

NOTE: 

The use of a firewood moisture meter is rec-

ommended to ensure the firewood contains 

less than 20% moisture.

Seasoning Guide

Softwoods  -  6 months to 18 months

Hardwoods  -  12 months to 24 months
Logs that are 5” diameter across or larger should 

be split in half, three pieces if over 8 inches, and 

four pieces when over a foot across.  If a tree 

has been dead for 2  -  4 years it still needs to 

be cut, split, and seasoned for 6 to 24 months 

depending on the wood.

4' 

4' 

8' 

Standard 

Cord of

Wood

8 Ft. 

(2.4M)

4 Ft. 

(1.2M)

4 Ft. (1.2M)

Figure 3

Figure 2

MAINTENANCE AND CARE

Chimney Maintenance

Regular chimney inspection and maintenance 

combined with proper operation will prevent 

chimney fires. Keep your chimney clean.  Do not 

allow more than 1/16” (1.6 mm) creosote build 

up in your chimney.  The amount of creosote 

will depend on variables such as frequency of 

use and type of fire.  We recommend that you:

A.  Initially inspect the chimney system weekly.  

From this, you will learn how often it will be 

necessary to clean your chimney.

B. Have your chimney cleaned by a qualified 

chimney sweep.  If you wish to clean it 

yourself, we recommend using a stiff plastic 

or non-metallic brush.  If a metal brush is 

used, its size should be slightly smaller than 

the flue to avoid damaging the chimney.  Do 

not use a brush that will scratch the stainless 

steel interior of the chimney.

C. Do not expect chemical cleaners to keep 

your chimney clean.  The rain cap can be 

removed for inspection and/or cleaning of 

the chimney. 

CAUTION: It is necessary to remove the baffle 

from the top of the firebox before cleaning the 

chimney. See “Top Baffle Removal Prior To 

Chimney Sweep.”

Dealing With a Chimney Fire

Regular chimney maintenance and inspection 

can prevent chimney fires.  If you have a chimney 

fire, follow these steps:

1.  Close the fireplace door and the combustion 

air controls.

2. Alert your family of the possible danger.

3. If you require assistance, alert your fire 

department.

4. If possible, use a dry chemical fire extin-

guisher, baking soda or sand to control the 

fire.  Do not use water as it may cause a 

dangerous steam explosion.

5.  Check outside to ensure that sparks and hot 

embers coming out of the chimney are not 

igniting the roof.

6. Do not use the fireplace again until your 

chimney and fireplace have been inspected 

by a qualified chimney sweep or a Fire 

Department Inspector.

     WARNING

Disposal of Ashes:  Ashes should 

be placed in a metal container 

with a tight-fitting lid. The closed 

container of ashes should be 

placed on a noncombustible floor 

or on the ground, well away from 

all combustible materials, pend-

ing final disposal. If the ashes are 

disposed of by burial in soil or 

otherwise locally dispersed, they 

should be retained in the closed 

container until all cinders have 

thoroughly cooled.

     WARNING

When processed solid fuel fire-

logs are used:  Do not poke or stir 

the logs while they are burning. 

Use only firelogs that have been 

evaluated for the application 

in fireplace and refer to firelog 

warnings and caution markings 

on packaging prior to use.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

6

Summary of Contents for WCT4920WS

Page 1: ...s This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your installat...

Page 2: ...Air Intake Pipe 4 10 16 x 3 4 Tek Screws Safety Metal Strip Top standoff assembly loose on top of unit PARTS REQUIRED Fireplace Model 6 diameter chimney United States Model IHP Snap Pak including Chim...

Page 3: ...it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sell...

Page 4: ...ne normally used since it will deposit the least amount of creosote on the glass and in the chimney The combustion air control must be 3 4 closed and pushed in to close the air boost The precise WARNI...

Page 5: ...protectors metallic paper coal plastic waste beach wood Christmas tree sul phur and or oil will damage the fireplace G Donotburndriftwoodwhichhasbeeninthe ocean or salt water The salt will corrode th...

Page 6: ...If you wish to clean it yourself werecommendusingastiffplastic or non metallic brush If a metal brush is used its size should be slightly smaller than the flue to avoid damaging the chimney Do notuse...

Page 7: ...greenorfreshlycuthardwoods DONOTBURN Garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Wastepetroleumproducts paintsorpaintthinners or aspha...

Page 8: ...specifically designed for this fireplace The fireplace cannot be operated with out door Consult your dealer to select the correct replacement door Important Toassureproperalignment of glass doors Ins...

Page 9: ...the other half must extend on the floor over which the hearth extension will be built see Figure 8 The safety metal strip must cover the entire width of the fireplace The combustible floor in front of...

Page 10: ...t of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts optional outside air kit and chimney Ifpossible youshouldchoosealocationwhere thec...

Page 11: ...y facing material installed on the front of thefireplace Ifthickermaterialisinstalled use the facade as a template and make sure it can be easily removed for servicing Outside Chase Zero Clearance fro...

Page 12: ...d in the same man ner using the same insulation as the rest of the building below the attic 7 Ft Min Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2 x 4 Firep...

Page 13: ...stible Material Inches millimeters Drywall Facade Facade Facade Facade Drywall Drywall Jack Stud Jack Stud Jack Stud Jack Stud 32 1 2 826 32 1 2 826 31 1 2 826 22 3 8 569 28 3 8 721 28 3 8 721 Louvere...

Page 14: ...sing the side nailing flange as semblies shown in Figure 14 Fireplace Side Nailing Flange 2 places each side Unbend to floor and nail screw Figure 15 Non Combustible Mantel Rock Board or Other Noncomb...

Page 15: ...andirons from inside the firebox Figure 17A 4 Remove the bottom refractory panels pieces 1 and 2 Figure 6 Page 8 Remove the 14 Cap screws with a 5 32 Allen Key see Figure 17B 5 Unplug the blower Figur...

Page 16: ...e and the air inlets Carefully push the insulation and plastic cover back over the pipe Using aluminium tape fasten the plastic cover in place Figure 19A Outside Connection Figure 19B Aluminum Tape Al...

Page 17: ...A Fireplace HeatFlo Convection Kit Cat No Model Description F3790 EPA HEATFLO KIT EPA Heatflo Conv Kit Table 2 GENERAL INFORMATION If you encounter any problems need clarification of these instruction...

Page 18: ...1 280mm Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex k...

Page 19: ...e outlet grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side w...

Page 20: ...having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm above its po...

Page 21: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Page 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Page 23: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Page 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Page 25: ...place is normally supplied with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch...

Page 26: ...chimney at 30 3 Increase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip thr...

Page 27: ...0 long UZI UZI EPA Fireplace HeatFlo Convection Kit Mandatory for Clean Face Facade Installations EPA Heatflo Conv Kit EPA HEATFLO KIT F3790 OPTIONAL INSTALLATION ACCESSORIES Fireplace Kits Descriptio...

Page 28: ...9 Top Standoff Header Shield Assy F4713 Damper Rod H8393 Damper Handle Extension F4784 Ash block Louvered Facades F4800 SPECIFICATIONS REPLACEMENT PARTS LIST Cat No Model No F4779 WCT4920WS Product Re...

Page 29: ...our Security Chimneys or DuraVent Distributor or Dealer for ordering information 450 973 9999 1 800 361 4909 USA 1 800 667 3387 Canada 1 800 835 4429 Security Chimneys 2125 Monterey Laval Quebec Canad...

Page 30: ...MEURER TOTALEMENT FERM E LORSQUE LE FOYER FONCTIONNE NE PAS UTILISER DE PO LE ENCASTRABLE OU D AUTRES PRODUITS NON SP CIFI S COMME TANT UTILISABLES AVEC CE PRODUIT CONTACTEZ LES RESPONSABLES DE VOTRE...

Page 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Page 32: ...or any questions or concerns REPLACEMENT PARTS See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP di...

Reviews: