background image

SAFETY / LISTING LABEL  

WCT4920WS

Model / Modèle:  WCT4920WS

Serial No. Numéro de série

LISTED 

FACTO

RY BUI

LT FIREPLACE

FOYER PRÉ

FABRIQUE HOMOLOGUÉ

Manufactured by / Fabriqué par: INNO

VA

TIVE HEA

RTH PRODUCTS

1502 14th St. NW

Auburn, 

W

A  98001 USA

P/N 901177-00, 

RE

V. 0, 07/2021

FIREPLACE, ALSO FOR USE IN MANU

FACTURED 

HOMES WITH SOLID FUEL ON

LY

CE FOYER EST ÉGALEMENT CE

RTIFIÉ POUR 

INS

TALL

ATION DANS LES MAISONS MOBILES. 

COMBUSTIBLES SOLIDES SEULEMEN

T.

Conforms to / Conforme au :  UL STD 127

Certified to / Certifié au :   ULC STD S610

C

US

Report No. / Rapport nº

14-199 R1

 

Date of Manufacture /  Date De Fabrication

 

202

202

202

 J

AN

 

 FE

M

AR

 

AP

M

AY

 

 J

UN

 

 J

UL

  

AU

 

SE

 O

CT

 

NO

DE

C

 

  

  

  

JAN

FEV

M

AR

AV

 M

AI

 

 J

UI

 J

UI

 A

SEP

 O

CT

 

NO

 DE

C

CLEARANCES TO COMBUSTIBLES:

SID

W

AL

(F

RO

M

 FIREB

OX 

OPENI

NG

24 in. (610 mm)

FRAME HEIGHT OPENING 

56 in. (1422 mm)

BACK 

W

ALL (FROM S

TANDOFFS)

 

0 in. 

 (0 mm)

CEILING HEIGHT (FROM BASE OF 

     FIREPLACE) 

ft.

 8

 in.

 (2032

 mm)

CHIMNEY 

2 in. 

 (51 mm)

DÉGAGEMENTS AUX COMBUSTIBLES:

MUR L

ATÉRAL (À 

PA

RTIR DE 

L’OUVE

RTURE DE LA 

     CHAMBRE DE COMBUSTION) 

24 po.

 (610 mm)

OUVE

RTURE HAUTEUR DU CADRE 

56 po. (1422 mm)

MUR ARRIÈRE (À 

PA

RTIR DES ENTRETOISES 

     DE DÉGAGEMENT) 

0 PO. 

 (0 MM)

AU-DESSUS DU FOYER (À 

PA

RTIR DE LA BASE 

      DU FOYER) 

6 pi. 8 po. (2032 mm)

CHEMINÉE 

2 po. 

 (51 mm)

U.S. ENVIRONMEN

TA

L PROTECTION

 AGENCY

EP

A certification test emission value 1.9 g/hr per 2020 NSPS (cordwood)

Valeur d’émission du test d’homologation 1,9 g/h selon la norme 2020 NSPS

MINIMUM CLEARANCES TO FINISHED FRAMED OPENING, IN INCHES

NOTE: Dimensions are to the standoffs

INS

TALL WITH MINIMUM CLEARANCES TO 

W

ALL 

AS SHOWN IN INCHES.

SIDE

W

ALL - BACK

W

ALL

INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

CORNER INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

FLOOR PROTECTOR MINIMUM DIS

TANCE 

FROM OPENING IN INCHES

HEA

RTH EXTENSION M

ATERIAL :

-   

 3/8 “ THICKNESS NON COMBUSTIBLE 

M

ATERIAL

-   

 OR EQUI

VALENT

FIREPLACE

FRONT

18”

36”

• 

POUR USAGE 

AVEC LE BOIS SEULEMENT

• 

UN

 TABLIER

 NON

 COMBUSTIBLE

 DOIT

 ÊTRE

 INS

TALLÉ

 À 

L’

AV

ANT

 DE

 L’AP

PAREIL

 S’ÉTENDANT

 DE

 18

 “(457

 MM) 

À 

L’

AV

ANT ET 

AVOIR UNE LARGEUR D’AU MOINS

 

39” (991 MM).

• 

LE

S M

ANT

EA

UX D

CHE

M

IN

ÉE

 D

OI

VE

NT Ê

TRE N

ON C

OM

-

BU

STI

BL

ES

.

• 

AV

ER

TI

SSE

M

ENT

 : 

CE

 FOYER

 N’EST

 P

AS

 HOMOLOGUÉ 

POUR

 ÊTRE

 UTILISÉ

 A

VEC

 UN

 ENSEMBLE

 DE

 BÛCHES 

À 

G

AZ

 SAN

CONDUI

D

’É

VA

CU

AT

ION

AF

IN

 D

RÉDUIRE

 LES

 RISQUES

 D’INCENDIE

 OU

 DE

 BLESSURES, 

N’INS

TALLEZ

 P

AS

 DE

 BÛCHES

 À

 GAZ

 SANS

 CONDUIT 

D’É

VACU

ATION À 

L’INTÉRIEUR DE CE FOYER.

• 

ALIMEN

TA

TION ÉLECTRIQUE: 120

V, 60 Hz

• 

TYPE

 DE

 CHEMINÉE:

 UTILISER

 SEULEMENT

 A

VEC

 6

 PO. 

DIAMÈTRE

 - 

ÉT

ATS-UNIS:

 IHP

 SNAP-

PAK;

 CAN:

 SECURE 

TEMP

 ASHT

 +

 OU

 S2100

 +,

 DUR

ATECH

 CANADA

 OU 

DUR

ATECH PREMIUM.

• 

PEUT

 Ê

TRE

 R

ACC

ORDÉ

 S

UR

 U

N

CHEMINÉ

D

M

ON

N

ER

IE

 TE

Q

U

D

ÉC

R

IT

 D

AN

LE

 M

AN

U

EL 

D’INS

TALL

ATION.

• 

LES

 CO

M

PO

SA

NT

ES

 U

TIL

IS

ÉE

AV

EC

 LE

 F

OY

ER

 D

OI

VE

NT 

ÊTRE

 HOMOLOGUÉES.

 VOIR

 LA

 LISTE

 DANS

 LE

 MANUEL 

D’INS

TALL

ATION.

• 

REMPLACER

 LA

 VITRE

 A

VEC

 UN

 VERRE

 CÉRAMIQUE

 DE 

5mm D’É

PAISSEUR.

• 

PO

UR

 U

N

UTI

LIS

ATI

O

N

 SÉ

CURI

TA

IRE,

 I

NS

TA

LLE

CONFORMÉMENT AUX DIRECTIVES DU 

FABRICAN

T.

• 

ATTENTION

 : 

NE

 P

AS

 OBSTRUER

 LES

 ARRIVÉES

 D’AIR 

COMBURAN

T.

• 

NE 

PAS 

FAIRE SURCHAUFFER LE FOYER.

• 

LA

 PO

RTE

 DU

 FOYER

 DOIT

 DEMEURER

  

TO

TALEMENT 

FERMÉE LORSQUE LE FOYER FONCTIONNE.

• 

NE

 P

AS

 UT

IL

IS

ER

 DE

 POÊLE

 EN

CA

STR

AB

LE

 OU

 D

’AUTRE

PR

OD

UIT

NO

SPÉ

CIF

IÉS

 C

OM

M

ÉT

ANT

 UT

IL

ISAB

LE

AVEC CE PRODUI

T.

• 

CON

TACTEZ

 LES

 RESPONSABLES

 DE

 VOTRE

 REGION 

PR

OP

O

DE

RE

STR

IC

TIO

N

ET

 I

NSP

EC

TI

O

N

D’INS

TALL

ATION.

• 

MAINTENIR

 LES

 MEUBLES

 ET

 AUTRES

 OBJETS

 À

 UNE 

DIS

TANCE SÉCURI

TAIRE DU FOYER.

• 

CET

 AP

PAREIL

 DE

 CHAUF

FAGE

 AU

 BOIS

 DOIT

 ÊTRE 

INSPECTE

 ET

 ENTRETENU

 PÉRIODIQUEMENT

 POUR 

FONCTIONNER

 CORRECTEMEN

T.

 VOIR

 LE

 MANUEL 

DU

 PRO

PR

TA

IRE

 POUR

 PL

U

D

’IN

FOR

M

AT

ION

L’UTILIS

ATION

 DE

 CET

 AP

PAREIL

 DE

 CHAUF

FAGE

 AU 

BO

IS

 DE

 M

ANI

ÈR

IN

CO

M

PA

TIB

LE

 A

VE

LE

INS

TRU

C-

TI

ON

DU

 M

ANU

EL

 DU

 P

RO

PRI

ÉT

AI

RE

 C

ONS

TITU

E U

NE 

INFRACTION AUX RÉGUL

ATIONS FÉDÉRALES.

• 

USE WOOD FUEL ON

LY

• 

N

ON

-C

O

M

BU

STI

BL

H

EA

RT

H

 E

XT

EN

SI

O

N

 M

U

ST

 BE

 IN

ST

AL

LE

AT

 FRONT

 OF

 UNIT

 EXTENDING

 18

 IN.

 (457

 MM)

 IN

 CANADA 

(OR 16 IN. USA)  AND 39” (991 MM) WIDE MINIMUM.

• 

ANY

 M

AN

TEL

 MU

ST

 B

NON-

CO

M

BU

STI

BL

E

• 

W

AR

NING

: TH

IS

 FIREPLACE

 HAS

 NOT

 BEEN

 TESTED

 WITH

 UN

-

VENTED

 GAS

 LOG

 SE

T.

 TO

 REDUCE

 RISK

 OF

 FIRE

 OR

 INJU

RY

 DO 

NO

IN

ST

ALL

 A

N

 UN

VE

N

TE

D

 G

AS

 L

OG

 SET

 IN

TO

 T

H

FI

RE

PLA

CE

.

• 

ELECTRICAL R

ATING:  120 

V, 60 Hz

• 

CHIMNEY TYPE: USE ON

LY WITH 6 IN. DIAMETER -

 

USA:

 IHP

 SNAP-

PAK;

 CAN:

 SECURE

 TEMP

 ASHT+

 OR

 S2100+, 

DUR

ATECH CANADA OR DUR

ATECH PREMIUM.

• 

CAN

 BE

 CONNECTED

 TO

 A

 MASON

RY

 CHIMNEY

 AS

 DESCRIBED 

IN THE INS

TALL

ATION INSTRUCTIONS.

• 

COM

PONENT

US

ED

 WI

TH

 T

HE

 F

IREPL

AC

M

UST

 BE

 LI

ST

ED

.  SE

LI

ST

 IN

 TH

E IN

ST

ALL

ATION

 INS

TRUC

TIONS

.

• 

REPLACE GLASS WITH CERAMIC GLASS 5 mm THICK.

• 

FOR

 SAFE

 OPER

ATION

 INS

TALL

 IN

 ACCORDANCE

 WITH

 THE 

MANU

FACTURER’S INSTRUCTIONS.

• 

CAU

TION

COM

BU

STI

O

N

 A

IR

 O

PE

NING

 M

U

ST

 NOT

 B

O

B-

STRUCTED.

• 

DO NOT OVERFIRE THE FIREPLACE.

• 

OPER

ATE THE FIREPLACE WITH DOOR FUL

LY CLOSED ON

LY

.

• 

DO

 NO

US

FI

REPL

AC

INS

ER

OR

 OTHER

 PRODUCT

NO

SPE

CI

FI

ED FO

R US

WI

TH TH

IS PRODU

CT

.

• 

CON

TACT

 YOUR

 LOCAL

 BUILDING

 OR

 FIRE

 OFFICIALS

 ABOUT 

RESTRICTIONS

 AND

 INS

TALL

ATION

 INSPECTIONS

 IN

 YOUR 

AREA.

• 

SEE

 IHP

 INS

TALL

ATION

 AND

 OPER

ATING

 INSTRUCTIONS

 FOR 

THIS MODEL.

• 

KEEP

 FURNISHINGS

 AND

 OTHER

 COMBUSTIBLE

 M

ATERIALS

 A 

CONSIDERABLE DIS

TANCE 

AW

AY FROM APPLIANCE.

• 

TH

IS

 W

O

OD

 H

EA

TE

R

 NE

ED

PE

R

IOD

IC

 I

N

SP

EC

TI

O

N

 A

N

RE

PAIR

 FOR

 PROPER

 OPER

ATION.

 CONSU

LT

 THE

 OWNER’S 

M

ANUA

L FOR

 FU

RTH

ER

 IN

FORM

AT

IO

N.

 IT

 IS

 A

GA

IN

ST

 FED

ER

AL 

REGUL

ATIONS

 TO

 OPER

ATE

 THIS

 WOOD

 HE

ATER

 IN

 A

 MANNER 

INCONSISTENT

 WITH

 THE

 OPER

ATING

 INSTRUCTIONS

 IN

 THE 

OWNER’S MANUAL.

• 

INS

TALL

 AND

 USE

 ON

LY

 IN

 ACCORDANCE

 WITH

 THE

 MANU

-

FACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES.

• 

SP

ECIA

L M

ETH

OD

ARE

 RE

QU

IRED

 W

HE

PA

SSING

 TH

ROU

GH

 A 

W

ALL

 OR

 CEILING.

 SEE

 INSTRUCTIONS

 AND

 BUILDING

 CODES.

• 

PREVENT

 CREOSOTE

 FIRE:

 INSPECT

 CHIMNEY

 CONNECTOR 

AND CHIMNEY FLUE MONTH

LY AND CLEAN IF NECESSA

RY

• 

 DO

 NOT

 OVERFIRE.

 IF

 DOME

 OR

 CHIMNEY

 CONNECTOR

 GLOWS 

YOU ARE OVERFIRING.

MINIMUM FLOOR PROTECTION FROM OPENING

CENTERED ON FIREPLACE, IN INCHES

HEA

RTH EXTENSION M

ATERIAL:

M

INI

M

UM 

1/

2” T

HIC

KNESS

 N

ON-C

OM

BU

STIB

LE

.

 18” Min. Canada 

16” Min. USA

INS

TALL WITH MINIMUM CLEARANCES TO 

W

ALL 

AS SHOWN IN INCHES.

SIDE

W

ALL - BACK

W

ALL

INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

CORNER INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

FLOOR PROTECTOR MINIMUM DIS

TANCE 

FROM OPENING IN INCHES

HEA

RTH EXTENSION M

ATERIAL :

-   

 3/8 “ THICKNESS NON COMBUSTIBLE 

M

ATERIAL

-   

 OR EQUI

VALENT

FIREPLACE

FRONT

18”

36”

39”

Min. Depth *

30

Summary of Contents for WCT4920

Page 1: ...This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your installati...

Page 2: ...Air Intake Pipe 4 10 16 x 3 4 Tek Screws Safety Metal Strip Top standoff assembly loose on top of unit PARTS REQUIRED Fireplace Model 6 diameter chimney United States Model IHP Snap Pak including Chim...

Page 3: ...it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sell...

Page 4: ...ne normally used since it will deposit the least amount of creosote on the glass and in the chimney The combustion air control must be 3 4 closed and pushed in to close the air boost The precise WARNI...

Page 5: ...protectors metallic paper coal plastic waste beach wood Christmas tree sul phur and or oil will damage the fireplace G Donotburndriftwoodwhichhasbeeninthe ocean or salt water The salt will corrode th...

Page 6: ...seabrushthatwillscratchthestainless steel interior of the chimney C Do not expect chemical cleaners to keep your chimney clean The rain cap can be removed for inspection and or cleaning of the chimney...

Page 7: ...greenorfreshlycuthardwoods DONOTBURN Garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Wastepetroleumproducts paintsorpaintthinners or aspha...

Page 8: ...specifically designed for this fireplace The fireplace cannot be operated with out door Consult your dealer to select the correct replacement door Important Toassureproperalignment of glass doors Ins...

Page 9: ...the other half must extend on the floor over which the hearth extension will be built see Figure 8 The safety metal strip must cover the entire width of the fireplace The combustible floor in front of...

Page 10: ...t of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts optional outside air kit and chimney Ifpossible youshouldchoosealocationwhere thec...

Page 11: ...ny facing material installed on the front of thefireplace Ifthickermaterialisinstalled use the facade as a template and make sure it can be easily removed for servicing Outside Chase Zero Clearance fr...

Page 12: ...d in the same man ner using the same insulation as the rest of the building below the attic 7 Ft Min Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2 x 4 Firep...

Page 13: ...stible Material Inches millimeters Drywall Facade Facade Facade Facade Drywall Drywall Jack Stud Jack Stud Jack Stud Jack Stud 32 1 2 826 32 1 2 826 31 1 2 826 22 3 8 569 28 3 8 721 28 3 8 721 Louvere...

Page 14: ...S SIDE NAILING FLANGES Side Nailing Flanges 2 places Figure 16A Only non combustible mate rial should be superposed or projecting over the front of the fireplace 56 1422mm Min Noncombustible Facing Dr...

Page 15: ...andirons from inside the firebox Figure 17A 4 Remove the bottom refractory panels pieces 1 and 2 Figure 6 Page 8 Remove the 14 Cap screws with a 5 32 Allen Key see Figure 17B 5 Unplug the blower Figur...

Page 16: ...e and the air inlets Carefully push the insulation and plastic cover back over the pipe Using aluminium tape fasten the plastic cover in place Figure 19A Outside Connection Figure 19B Aluminum Tape Al...

Page 17: ...A Fireplace HeatFlo Convection Kit Cat No Model Description F3790 EPA HEATFLO KIT EPA Heatflo Conv Kit Table 2 GENERAL INFORMATION If you encounter any problems need clarification of these instruction...

Page 18: ...1 280mm Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex k...

Page 19: ...e outlet grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side w...

Page 20: ...having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm above its po...

Page 21: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Page 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Page 23: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Page 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Page 25: ...place is normally supplied with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch...

Page 26: ...chimney at 30 3 Increase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip thr...

Page 27: ...ated flex x 10 long UZI UZI EPA Fireplace HeatFlo Convection Kit Mandatory for Clean Face Facade Installations EPA Heatflo Conv Kit EPA HEATFLO KIT F3790 OPTIONAL INSTALLATION ACCESSORIES Fireplace Ki...

Page 28: ...9 Top Standoff Header Shield Assy F4713 Damper Rod H8393 Damper Handle Extension F4784 Ash block Louvered Facades F4800 SPECIFICATIONS REPLACEMENT PARTS LIST Cat No Model No F4779 WCT4920WS Product Re...

Page 29: ...our Security Chimneys or DuraVent Distributor or Dealer for ordering information 450 973 9999 1 800 361 4909 USA 1 800 667 3387 Canada 1 800 835 4429 Security Chimneys 2125 Monterey Laval Quebec Canad...

Page 30: ...MEURER TOTALEMENT FERM E LORSQUE LE FOYER FONCTIONNE NE PAS UTILISER DE PO LE ENCASTRABLE OU D AUTRES PRODUITS NON SP CIFI S COMME TANT UTILISABLES AVEC CE PRODUIT CONTACTEZ LES RESPONSABLES DE VOTRE...

Page 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Page 32: ...ler for any questions or concerns REPLACEMENT PARTS See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your I...

Reviews: