WCT4920WS Replacement Parts

Description

Cat. No.

Blower Assembly, Single

F3866

Blower Wiring Harness

F4801

Blower motor speed control (wall mount), VRUW

VRUW

Snap Switch, 110°-20°

H8682

Baffle refractory (2 pieces)

PR-ISO2205

Back refractory

PR-SR2996

Right side refractory

PR-SR2997G

Left side refractory

PR-SR2729D

Bottom refractory

PR-SR2201

Front refractory, right side

PR-SR2202D

Front refractory, left side

PR-SR2202G

Door handle

PR-SR1787

Hinge Assembly, Fireplace and Door

PR-SR2395TCE

Decorative Screw Caps, Brushed Nickel (2)

PR-SACMEFBN

Ceramic Glass Panel (Arched Doors)

PR-SR2222-1

Ceramic Glass Panel  (Square Door) 

PR-SR3004

Secondary Air Tube

PR-SR2271

Andiron (2 pieces)

PR-SR2897

Gasket Kit, Square Glass, 74” (3/16” x 1”)

PR-SR1685J

Gasket Kit, Square Door, 77-3/4” (3/4” dia)

PR-SR1823O

Gasket Kit, Arched Glass, 69” (1 x 5/16”)
(arched steel and cast doors)

PR-SR1823H

Gasket Kit, Arched Steel Door Frame, 73” (5/8” dia.)

PR-SR1685D

Gasket Kit, Arched Cast Door Frame, 73” (5/8” dia.)

PR-SR1823G

Touch-up Paint, Aerosol, Black Metallic SBMB6309

H8159

Touch-up Paint, Charcoal (for hammered steel facade)

PR-P6201

Coupler, Outside Air (connects UZI to fireplace)

UZIAD

Coupler for AC Chimney (connects ACZI to fireplace)

H3274

Blower 250 CFM for central forced air kit, BISZY

BISZY

Blower to flexible pipe adaptor, BISAVF

BISAVF

Backdraft Damper, BISBD

BISBD

Fireplace to Flex adaptor and 2 clamps, BISAF

BISAF

Metal Fab Collar and Sleeve

F4189

Top Standoff Header Shield Assy

F4713

Damper Rod

H8393

Damper Handle Extension

F4784

Ash block, Louvered Facades

F4800

SPECIFICATIONS

REPLACEMENT PARTS LIST

Cat. No.

Model No.

F4779

WCT4920WS

Product Reference Information

Weight

330 lbs

Height

38”

Width

37-1/4”

Depth

25-1/8”

Firebox W x H x D - measured in front

22” x 11-3/4” x 12”

Contact an IHP dealer to obtain any of these parts. Never use substitute 

materials not approved by IHP. Use of non-approved parts can result 

in poor performance and safety hazards.

Model

Emission Rate

Heat Output

EPA Estimated 

Efficiency

WCT4920WS

1.9 g/hr

15,277-55,597  btu/hr

72%

IHP SNAP-PAK CHIMNEY (USA) - PARTS AND COMPONENTS 

LISTS

The components listed below must be ordered from IHP.  Contact 

your IHP Distributor or Dealer for ordering information.  

6” Snap-Pak Chimney

Snap-Pak 6” Wood-Burning Chimney Lengths and Fittings (6” Inner Diam. - 9” Outer 

Diameter). Listed to UL103HT (2100° Intermittent, 1000° Continuous)

Description

Model

Cat. No.

6” SS Chimney Length (2pk)

6SPS6-2

F3966

12” SS Chimney Length (2pk)

6SPS12-2

F3967

18” SS Chimney Length (2pk)

6SPS18-2

F3968

24” SS Chimney Length

6SPS24

F3969

36” SS Chimney Length

6SPS36

F3970

48” SS Chimney Length

6SPS48

F3971

15° SS Elbow (2pk)

6SPSE15-2

F3972

30° SS Elbow (2pk)

6SPE30-2

F3973

Firestop Spacer

6SPFS

F3974

Insulation Shield

6SPIS

F3975

Flat Flashing

6SPFF

F3976

2/12-5/12 Flashing

6SPF5

F3977

6/12-10/12 Flashing

6SPF10

F3978

Roof Brace

6SPRB

F3980

Storm Collar

6SPSC

F3981

Round Cap with Spark Arrester

6SPC

F3982

Non-Insulated Wall Firestop

6SPWF

F3983

Adjustable Support

6SPAS

F3984

Wall Band

6SPWB

F3985

Support Band

6SPSB

F3986

28

Summary of Contents for WCT4920

Page 1: ...This installation manual will enable you to obtain a safe efficient and dependable installation of your fireplace system Please read and understand these instructions before beginning your installati...

Page 2: ...Air Intake Pipe 4 10 16 x 3 4 Tek Screws Safety Metal Strip Top standoff assembly loose on top of unit PARTS REQUIRED Fireplace Model 6 diameter chimney United States Model IHP Snap Pak including Chim...

Page 3: ...it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sell...

Page 4: ...ne normally used since it will deposit the least amount of creosote on the glass and in the chimney The combustion air control must be 3 4 closed and pushed in to close the air boost The precise WARNI...

Page 5: ...protectors metallic paper coal plastic waste beach wood Christmas tree sul phur and or oil will damage the fireplace G Donotburndriftwoodwhichhasbeeninthe ocean or salt water The salt will corrode th...

Page 6: ...seabrushthatwillscratchthestainless steel interior of the chimney C Do not expect chemical cleaners to keep your chimney clean The rain cap can be removed for inspection and or cleaning of the chimney...

Page 7: ...greenorfreshlycuthardwoods DONOTBURN Garbage Lawn clippings or yard waste Materials containing rubber including tires Materials containing plastic Wastepetroleumproducts paintsorpaintthinners or aspha...

Page 8: ...specifically designed for this fireplace The fireplace cannot be operated with out door Consult your dealer to select the correct replacement door Important Toassureproperalignment of glass doors Ins...

Page 9: ...the other half must extend on the floor over which the hearth extension will be built see Figure 8 The safety metal strip must cover the entire width of the fireplace The combustible floor in front of...

Page 10: ...t of the unit for the hearth extension and the mantel and taking into consideration the location of the hot air ducts optional outside air kit and chimney Ifpossible youshouldchoosealocationwhere thec...

Page 11: ...ny facing material installed on the front of thefireplace Ifthickermaterialisinstalled use the facade as a template and make sure it can be easily removed for servicing Outside Chase Zero Clearance fr...

Page 12: ...d in the same man ner using the same insulation as the rest of the building below the attic 7 Ft Min Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2 x 4 Firep...

Page 13: ...stible Material Inches millimeters Drywall Facade Facade Facade Facade Drywall Drywall Jack Stud Jack Stud Jack Stud Jack Stud 32 1 2 826 32 1 2 826 31 1 2 826 22 3 8 569 28 3 8 721 28 3 8 721 Louvere...

Page 14: ...S SIDE NAILING FLANGES Side Nailing Flanges 2 places Figure 16A Only non combustible mate rial should be superposed or projecting over the front of the fireplace 56 1422mm Min Noncombustible Facing Dr...

Page 15: ...andirons from inside the firebox Figure 17A 4 Remove the bottom refractory panels pieces 1 and 2 Figure 6 Page 8 Remove the 14 Cap screws with a 5 32 Allen Key see Figure 17B 5 Unplug the blower Figur...

Page 16: ...e and the air inlets Carefully push the insulation and plastic cover back over the pipe Using aluminium tape fasten the plastic cover in place Figure 19A Outside Connection Figure 19B Aluminum Tape Al...

Page 17: ...A Fireplace HeatFlo Convection Kit Cat No Model Description F3790 EPA HEATFLO KIT EPA Heatflo Conv Kit Table 2 GENERAL INFORMATION If you encounter any problems need clarification of these instruction...

Page 18: ...1 280mm Min Duct Ring Duct Adaptor Tab It is recommended that the ducted flex kit duct system be installed in the following order 1 Plan and frame fireplace and outlet locations prior to ducted flex k...

Page 19: ...e outlet grill The minimum height from thebottomoftheunittothecenteroftheoutletis68 1 7m with the minimum distance from the center of outlet to the ceiling and for the center of the outlet to a side w...

Page 20: ...having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is nine 9 feet 2 75 m 6 The chimney must extend at least three 3 feet 915 mm above its po...

Page 21: ...er of equal size to the joist should be used Figure 26 FEMALE END MALE END BUTTON LOCK ATTACH FOR LOCK Figure 27 INSULATION SHIELD CAT NO SPIS NAIL FIRESTOP CAT NO SPFS Chimney Flue Diameter 6 A 12 7...

Page 22: ...ance to combustibles AT THIS POINT TIGHTEN CLAMPS 11 Slide IHP chimney pipe into top of tee Align male and female ends Push down on pipe sec tions until locked As sections are added it will be necessa...

Page 23: ...all the next SP chimney section through the roof See Figure 32 NOTE If your roof is already shingled be sure to slide the upper edge under the shingles to prevent leakage 3 Install a bead of caulk aro...

Page 24: ...verse wind conditions etc may create a need for a taller chimney should smoking occur Additional support is required above the roof if the chimney height exceeds four 4 feet Select the proper support...

Page 25: ...place is normally supplied with a chimney adaptor suitable for use with IHP SnapPak venting In Canada the use of Security Chimneys ASHT adaptor is required Security part number 6IHP1 or 6IHP2 One inch...

Page 26: ...chimney at 30 3 Increase the size of the hole until a 30 liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip thr...

Page 27: ...ated flex x 10 long UZI UZI EPA Fireplace HeatFlo Convection Kit Mandatory for Clean Face Facade Installations EPA Heatflo Conv Kit EPA HEATFLO KIT F3790 OPTIONAL INSTALLATION ACCESSORIES Fireplace Ki...

Page 28: ...9 Top Standoff Header Shield Assy F4713 Damper Rod H8393 Damper Handle Extension F4784 Ash block Louvered Facades F4800 SPECIFICATIONS REPLACEMENT PARTS LIST Cat No Model No F4779 WCT4920WS Product Re...

Page 29: ...our Security Chimneys or DuraVent Distributor or Dealer for ordering information 450 973 9999 1 800 361 4909 USA 1 800 667 3387 Canada 1 800 835 4429 Security Chimneys 2125 Monterey Laval Quebec Canad...

Page 30: ...MEURER TOTALEMENT FERM E LORSQUE LE FOYER FONCTIONNE NE PAS UTILISER DE PO LE ENCASTRABLE OU D AUTRES PRODUITS NON SP CIFI S COMME TANT UTILISABLES AVEC CE PRODUIT CONTACTEZ LES RESPONSABLES DE VOTRE...

Page 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Page 32: ...ler for any questions or concerns REPLACEMENT PARTS See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your I...