background image

SuperiorFireplaces.us.com

126628-01_J

20

ACCESSORIES 

Continued

ANTI-DRAFT SHIELD

(Round Top Termination Only)

F0927

ADS-8DM

Anti-Draft Shield for Round Top Only

MESH ROUND TOP TERMINATIONS

F0916

RT-8DM

Round Top with Mesh Screen

F0888

RT-8HT

Hi-Temp Round Top with Mesh Screen

MESH ROUND TOP TERMINATIONS WITH SLIP SECTION

F0917

RTT-8DM

Round Top with Slip Section & Mesh

F0889

RTT-8HT

Hi-Temp Round Top w/Mesh Screen and Slip Section

ROUND TOP TERMINATIONS WITH LOUVERS

F0918

RLT-8DM

Round Top with Louvered Screen

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

ROUND TOP TERMINATIONS WITH LOUVERS W/SLIP SECTION

F0919

RLTT-8DM

Round Top with Slip Section & Louvers

F0891

RLTT-8HT

Hi-Temp Round Top w/Lvrd. Screen and Slip Section

SQUARE TOP TERMINATION WITH LOUVERS

F0920

ET-8DM

Square Top

F0892

ET-8HT

Hi-Temp Pyramid Top with Slip Section

SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION

F0921

ETL-8DM

Square Top with Slip Section

F0893

ETL-8HT

Hi-Temp Large Pyramid Top with Slip Section

MESH SQUARE TOP TERMINATION

F0922

ETO-8DM

Square Top with Mesh

MESH SQUARE TOP TERMINATION WITH SLIP SECTION

F0923

ETLO-8DM

Square Top with Mesh and Slip Section

ADJUSTABLE HOOD

Required when installing a vent-free gas log in this fireplace.

F1764

GA6050

Black Fireplace Hood

FIRESTOP THIMBLE

F0911

38FST

Firestop Thimble ( Use when penetrating a joist)

F0912

FST30

Firestop Thimble ( Use when offsetting through a joist)

BLOWER KIT

F1081

BK

Manual Fan, Variable Speed

LABEL-UL127-50PK

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

900599-01

F2659

LABEL-UL127-

50PK

UL127 Venting Label - 50 PK

Summary of Contents for WCT2036WS

Page 1: ...The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autor...

Page 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Page 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Page 4: ...T LESS THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT 13 7 8 353 mm 9 1 8 232 mm 3 4 19 mm...

Page 5: ...iling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensi...

Page 6: ...l Safe Zone For Projection of Combustible Materials Upper Section of Circulating Fireplace Top of Louvered Opening Fireplace Opening Note Drawing Not to Scale 8 204 mm 1 26 mm Min 12 305 mm from Perpe...

Page 7: ...eceptacle and Ground Sheet Metal Screws Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of x 20 7 mm x 508 mm in size Air Inlet Location Must Allow For Bushes or Snow V...

Page 8: ...cal chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combina...

Page 9: ...Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m A B C Ceiling Support Pipe 12S 8DM Ceiling Support Pipe 12S 8DM Figure 10 Cei...

Page 10: ...A Screws OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 25 3 4 1 11 7 8 31 1 15 37 3 8 1 16 3 4 40 1 2 1 1 20 47 1 8 1 22 5 8 52 1 8 1 1 25 1 2 57 7 8 1 27 5 8 62 1 1 30...

Page 11: ...l it is snug against open edge of flashing see Figure 16 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney P...

Page 12: ...shroud is to be installed contact manufacturer for specifications 24 610 mm Min 24 610 mm Min 18 458 mm Min Typ Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0...

Page 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Page 14: ...h glass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too la...

Page 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Page 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2036WS WRT2036WSI WCT2036WS WCT2036WSI MODEL CAT NO WRT2036WS F0683 WRT2036WSI F0684 WCT2036WS F0685 WCT2036WSI F0686 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Page 17: ...ner 1 13 See Page 18 Right Side Brick Liner 1 14 See Page 18 Bottom Brick Liner 1 15 See Page 18 Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulat...

Page 18: ...to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 ACCESSORIES REFRACTORY STAIN K...

Page 19: ...Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT...

Page 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Page 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Page 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Page 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Page 24: ...6628 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Reviews: