OPTIONAL GAS LINE INSTALLATION
Continued
CAUTION: All gas piping
and connections must be tested
for leaks after the installation is
completed. After ensuring that
the gas valve is on, apply soap
and water solution to all con-
nections and joints. Bubbles
forming show a leak. Correct
all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK
TESTING AND DO NOT OPER-
ATE ANY APPLIANCE IF A LEAK
IS DETECTED. LEAK TESTING
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON.
WARNING: If the fireplace
has been used for wood burning,
the firebox and chimney must be
cleaned of soot, creosote and
ashes be a qualified chimney
cleaner. Creosote will ignite if
heavily heated.
WARNING: When using a
decorative vented gas log, the
damper must be removed or
permanently locked in the fully
open position and the glass doors
must be in the fully open position.
WARNING: Do not operate an
unvented gas log set in this fire
-
place with the chimney removed.
If you install a decorative gas appliance
(vented gas log), the decorative gas appliance
must comply with the
Standard for Decorative
Gas Appliance for Installation in Solid Fuel
Burning Fireplaces, ANS Z21.60 or Z21.84
and shall also be installed in accordance with
the
National Fuel Gas Code, ANSI 7223NFPA
54 latest edition
.
If you wish to install an unvented (vent-free)
gas log set, only unvented gas log sets which
have been found to comply with the standard
for unvented room heaters, ANSI Z21.11.2 are
to be installed in this fireplace.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• appliance will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If
so, contact your local propane/LP or natural
gas supplier.
TECHNICAL SERVICE
You may have further questions about instal-
lation, operation, or troubleshooting. Please
contact your IHP dealer for any questions or
concerns. When contacting your dealer please
have your model and serial numbers of your
appliance ready. You can also visit our web site
at SuperiorFireplaces.us.com.
REPLACEMENT PARTS
See
Pages 18-22
for a complete replacement parts
list. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your
IHP distributor or dealer. Parts will be shipped at
prevailing prices at time of order.
When ordering repair parts, always give the following
information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any ques-
tions concerning the installation or application of
this appliance, please contact your dealer.