PRODUCT FEATURES
OPERATION
This fi rebox is designed for use with approved
ANSI Z21.11.2 decorative type unvented room
heaters. (Physical size limitations apply. Refer
to minimum fi rebox requirements supplied
with log heater.) It requires no outside vent-
ing or chimney making installation easy and
inexpensive.
LOCAL CODES
LOCATING FIREBOX
PLANNING
Plan where you will install the fi rebox. This will
save time and money later when you install
the fi rebox. Before installation, consider the
following:
1. Where fi rebox will be located. Allow for
wall and ceiling clearances
(see Installa-
tion Clearances, Page 11).
2. Everything needed to complete installation.
3. These models CANNOT be installed in
a bedroom unless maximum Btu rating
of installed vent-free log set is less than
10,000 Btu/hr.
4. Proper air for combustion and ventilation
(Page 8).
Install and use fi rebox with care. Follow all
local codes. In the absence of local codes,
use the latest edition of
The National Fuel
Gas Code ANSI Z223.1/NFPA 54
*
; National
Fuel Gas Code
(latest edition). Firebox must
be electrically grounded in accordance with
the
National Electrical Code, ANSI/NFPA 70
(latest edition).
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th fl oor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
COMMONWEALTH OF MASSACHU-
SETTS REQUIREMENTS
These appliances are approved for installa-
tion in the US state of Massachusetts if the
following additional requirements are met:
• Un-vented Room Heaters shall be in-
stalled in accordance with 527 CMR 30.
• Installation and repair must be done by
a plumber or gas fi tter licensed in the
Commonwealth of Massachusetts.
• The fl exible gas line connector used shall
not exceed 36 inches (92 centimeters)
in length.
• The individual manual shut-off must be
a T-handle type valve.
• Unvented appliances may NOT be in-
stalled in bedrooms or bathrooms.
• A working smoke detector must be
installed in the area where vent-free ap-
pliances are installed.
Seller of unvented propane or natural
gas-fi red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.