Carefully follow these instructions. This will
ensure safe installation.
Minimum Wall and Ceiling Clearances
(see Figure 6)
A. Clearances from the side of fireplace
cabinet to any combustible material and
wall should follow diagram in
Figure 6
.
Example:
The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/
2
" from the wall. This com-
bustible material must be 4" from the side
of the fi replace cabinet
(see Figure 6).
B. Clearances from the top of fi rebox opening
to ceiling should not be less than 42".
C. When fi rebox is installed on carpeting or
other combustible material, other than
wood fl ooring, fi rebox should be installed
on a metal or wood panel extending the
full width and depth of enclosure.
D. Clearances from bottom of fi rebox to the
fl oor is 0".
These fi reboxes can be installed as freestand-
ing units against a wall with the approved,
optional cabinet mantels
(see Accessories,
Page 22)
or as a built-in unit. Clearances are
the same for either installation method.
INSTALLATION
Continued
*Minimum 16" from Side Wall
*
Example
Mantel Clearances for Built-In Installation
If placing custom mantel above built-in fi rebox,
you must meet the minimum allowable clear-
ance between mantel shelf and top of fi rebox
opening shown in
Figure 7, Page 12
. These
are the minimum allowable mantel clearances
for a safe installation. Use larger clearances
wherever possible to minimize the heating of
objects and materials placed on the mantel.
Figure 6 - Minimum Clearance for
Combustible to wall
CAUTION: Do not install the
fi rebox directly on carpet or vinyl.
CAUTION: Do not allow the vent-
free gas log heater to touch or extend
beyond the fi replace screen.
NOTICE: Surface temperatures of ad-
jacent walls and mantels become hot
during operation. Walls and mantels
above the fi rebox may become hot to
the touch. If installed properly, these
temperatures meet the requirement
of the national product standard. Fol-
low all minimum clearances shown
in this manual.
NOTICE: If your installation does
not meet the minimum clearances
shown, you must do one of the fol-
lowing:
• raise the mantel to an acceptable
height
• remove the mantel
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this fi rebox involves
installing fi rebox into a framed-in enclosure.
This makes the front of fi rebox fl ush with wall.
Optional brass trim accessories are available
(see Accessories, Page 22).
The brass trim
will extend past sides of fi rebox approximately
1/2". This will cover the rough edges of the
wall opening. If installing a mantel above the
fi rebox, you must follow the clearances shown
in
Figure 7
. Follow the instructions below to
install the fi rebox in this manner.