SuperiorFireplaces.US.com
126712-01C
15
INSTALLATION
Continued
Figure 13 - Accessing Blower Compartment
(Controls Not Shown for Clarity)
Figure 12 - Fan Switch-Electrical
Bushing
2.
Slide power source wiring through
electrical bushing opening and electri-
cal cover plate and make all necessary
connections.
3.
Slide all wiring connections in electrical
housing as shown in
Figure 12
.
4.
Secure electrical cover plate with screws
previously removed.
NOTE: Electrical housing and cover plate
have sharp edges. Wear protective gloves.
Decide which way you intend to gain access
into the bottom rear of the fi rebox to install the
blower accessory. The lower front panel can
be removed easily by snapping out the front
with a fl at blade screwdriver. Use caution not
to scratch any surfaces. Models with louvered
front panels can also be removed by inserting
fi ngertips between slots and gently pulling out.
DO NOT FORCE. The panels are actually
held in place by means of a retention dimple
embossed on the edge of removable panels.
Accessibility to the bottom on 36" and 42"
models only, can also be gained through the
access panel underneath the bottom front
refractory brick liner.
Lift the bottom front refractory brick liner up
and out of the fi rebox fl oor, exposing the
rectangular shaped access pane
l (see Figure
13)
. The sides and back refractory brick liner
pieces do not have to be removed. Lift ac-
cess panel out by using fi nger holes. Blower
accessory BK or BK3 can now be installed.
Duplex Electrical Outlet
Figure 14 - Accessing Duplex Electrical
Outlet Installed in Bottom Right Side of
Firebox
WARNING: If there is a duplex
electrical outlet installed in the
right side of the bottom of the
fi replace base area (see Figure
14), be sure that the electrical
power to the outlet is turned off
before proceeding with blower
installation. Failure to do this
may result in serious injury.
Electrical
Bushing
Electrical
Cover
Plate
Electrical
Housing
Wire Nut (3x)
(Not Supplied)
Outer Wrapper
of Fireplace
Electrical Cover
Plate and
Electrical Bushing
Fireplace Chassis
Ground
To Power
Source
Receptacle
(Supplied)
Power Source Wiring
(Not Supplied)
Prewired Receptacle
and Ground
Sheet
Metal
Screws
Front
Refractory
Panel
Lower
Panel
Control
Access
Cover