INSTALLATION
Figure 7 - Minimum Mantel Clearances
for Built-In Installation
Figure 8 - Rough Opening Dimensions
Supplied
Firebox Hood
Must Be Used
at All Times
Wire-mesh
Screen
Firebox
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
12" 16" 20"
1
1
/
2
"
6
3
/
4
"
12"
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
Rough Opening Dimensions for
Built-in Installation
Model
Front Width
(Inside to Inside)
Height
Depth
(Min.)
32"
34
1
/
2
"
36
5
/
8
"
16
5
/
8
"
36"
41
3
/
8
"
40
1
/
4
"
21
1
/
8
"
42"
48
1
/
4
"
43
3
/
4
"
23
1
/
2
"
Table 1
Depth
(Minimum)
Width
(Inside to Inside)
Height
Figure
8a
Figure
8b
Figure
8c
Figure
8d
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this fi rebox involves
installing fi rebox into a framed-in enclosure.
This makes the front of fi rebox fl ush with wall.
Optional brass trim accessories are available
(see Accessories, Page 22)
. The brass trim
will extend past sides of fi rebox approximately
1/2". This will cover the rough edges of the
wall opening. If installing a mantel above the
fi rebox, you must follow the clearances shown
in
Figure 7
. Follow the instructions below to
install the fi rebox in this manner.
1. Frame in rough opening. The fi rebox fram-
ing should be constructed of 2 x 4 lumber
or heavier. Use dimensions in Table 1
and rough opening layout in
Figure 8a
.
Adjust framing so that firebox flushes
with fi nished wall surface. If installing in
a corner, use dimensions in
Figures 8b,
8c and 8d
for rough opening.
2. Install gas piping to fi rebox location. See
Installing Gas Line,
Page 14
and
Con-
necting to Gas Supply
in log set owner’s
manual.
* These dimensions allow for min. Clearances
to a 45° projected side wall. However, clear-
ances to projected mantel trims and facings are
allowed within a min. Of 16" to a perpendicular
wall as shown in
Figure 6, On Page 11
.
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one
of the following:
• raise the mantel to an ac-
ceptable height
• remove the mantel