PARTS

This list contains replaceable parts used in your 

fi

 replace. When ordering parts, follow the 

instructions listed under 

Replacement Parts 

on 

Page 33

 of this manual.

PARTS AVAILABLE — NOT SHOWN

F2949

ODS Remote Wiring Harness

1

J7933

V-Wire

1

F2934

Harness, Wire

1

F3394

Wire, Harness

1

K2026

Cord, Power Supply

1

J3795

Wire, Harness

1

J3658

Plate, Warning

1

J6207

Kit, Platinum Embers

1

J6208

Kit, Glowing Embers (rockwool)

1

F2950

Remote Control ODS Touchscreen •

1

F2957

ODS Spark Wire

1

J6585

Plate, Lighting Instructions

1

J6598

Flex Line, 8'' .375 Tube W/Nuts

1

J6599

Flex Line, 12'' .375 Tube W/Nuts

1

J6599

Flex Line, 12'' .375 Tube W/Nuts

2

J6504

Chunk, Left Ember

1

J6505

Chunk, Middle Ember

1

J6506

Chunk, Right Ember

1

KEY 

NO.

PART NO.

DESCRIPTION

QTY.

VRT4032ZEN

VRT4036ZEN

VRT4032ZEP

VRT4036ZEP

Summary of Contents for LBG18BM

Page 1: ...d gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section...

Page 2: ...manual for reference It is your guide to safe and proper operation of this heater WARNING FIRE EXPLOSION AND ASPHYXIATION HAZARD Improperadjustment alteration service maintenance orinstallationofthis...

Page 3: ...s heater with the fireplace screen and hood in place before running heater The fireplace screen shall have openings for introduction of combus tion air Keeptheapplianceareaclearandfreefrom combustible...

Page 4: ...e powder residue within burner box or on adjacent walls or furniture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff sys...

Page 5: ...e connector used shall not exceed 36 inches 92 centimeters in length The individual manual shut off must be a T handle type valve Unvented appliances may NOT be installed in bedrooms or bathrooms A wo...

Page 6: ...kup heat SAFETY DEVICE This fireplace has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot system shuts o...

Page 7: ...confined Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them DETERMINING FRESH AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confine...

Page 8: ...200 Btu Hr maximum the space can support 73 000 Btu Hr actual amount of Btu Hr used The space in the example is a confined space because the actual Btu Hr used is more than the maximum Btu Hr the spac...

Page 9: ...rings or operating heater where impurities such as but not limited to tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls or cause odors WARNIN...

Page 10: ...not permitted ELECTRICAL HOOKUP This fireplace includes a blower which must be connected to either a wall receptacle or the electrical receptacle that is included within the fireplace If the receptacl...

Page 11: ...ce gas regulator to gas supply See Connecting Fireplace to Gas Supply Page 15 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conve...

Page 12: ...talling a mantel above the fireplace you must follow the clearances shown in Figure 16 Page 13 Follow the instructions below to install the fireplace in this manner 1 Frame in rough opening Use dimens...

Page 13: ...ssembly WARNING Do not allow noncombustible materials to cover any necessary openings like louvered slots WARNING Useonlynoncom bustiblemortaroradhesiveswhen overlapping the front facing with noncombu...

Page 14: ...Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace...

Page 15: ...ulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Tank Vent Pointing Down CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed 5 16 hex socket wrenc...

Page 16: ...eaks after installing or servicing Correct all leaks at once WARNING Never use an open flame to check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correc...

Page 17: ...off Valve Figure 23 Checking Gas Joints for Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Me...

Page 18: ...contain important safety and warranty information 1 Place fiber ramp log in center of chassis as shown in Figure 28 The fiber ramp log can be identified by the shape and much lighter weight when compa...

Page 19: ...ke sure the flame from the ember pan does not touch the ember bed log Figure 31 Installing Right Ember Bed Log VRT4036 Right Ember Bed Log Hole Underneath Grate Prong 5 The left middle log has a groov...

Page 20: ...the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the recessed areas on the rear and left middle logs see Figure 36 10 Rest the middle cros...

Page 21: ...bossed on the back of each piece for identification purposes Please note that VRT4032 series burner systems do not include ember chunks 2 Two ember materials are supplied with this log set Platinum Br...

Page 22: ...ee Page 44 for part numbers 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen brackets as shown in Figure 42 Push the bottom of the screen inward against the magnetic...

Page 23: ...ll come on automatically within one minute when the selector switchisintheONpositionafter the pilot is lit 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you...

Page 24: ...nate the backlight will not respond to associated zone function To activate any command the backlight for the screen must be on and the command must be touched before the backlight goes off Powered vi...

Page 25: ...Intermittent Pilot Ignition IPI Spark to Pilot only continuous standing pilot not allowed Pilot flame will be ignited before turn Main Flame ON LCD Displays MODE Zone ON is displayed ROOM TEMP Zone Me...

Page 26: ...E Zone Blank THERMOSTAT ON LCD Displays MODE Zone THERMO and ON are displayed ROOM TEMP Zone Measured tempera ture is displayed SET TEMP Zone SET TEMP is dis played TIME PROG Zone Current day indicato...

Page 27: ...setting To enter Program Setup touch and hold the TIME PROG Zone for 5 seconds Program OFF LCD Displays MODE Zone OFF ROOM TEMP Zone Measured tempera ture is displayed SET TEMP Zone Blank TIME PROG Z...

Page 28: ...s the control back ON and the room temperature is still 95F or greater the transmitter will switch to back manual OFF and send another OFF command the next time the transmitter reads updates the room...

Page 29: ...replace is shut off the blower will continue to operate until the fire place temperature cools The blower also includes a variable speed control Turn the knob clockwise to turn the blower to the high...

Page 30: ...d by fireplace causing brief patches of orange flame Figure 48 shows the correct burner flame The front ember burner should have a small blue flame When the ember material is ap plied the embers will...

Page 31: ...e Keep these holes clear of dust dirt lint and pet hair Clean these air in let holes prior to each heating season Blocked air holes will create soot We recommend that you clean the unit every three mo...

Page 32: ...t Outlet Thermocouple To S Terminal on Main Module Main Burner Battery Pack Primary or Backup Dry Contact Switches To Pilot Igniter From Pilot Thermocouple Regulator Inlet Gas Valve Valve Step Motor B...

Page 33: ...Ignition Electronic Manifold Pressure 8 W C Inlet Gas Pressure in of water Max 14 W C Min 11 W C For purpose of input adjustment SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit bur...

Page 34: ...tion sequence and observe the voltage while the system is lighting under load The system will not function under 3 8 volts and batteries should be replaced if the voltage is under 4 0 volts 2 Plug pow...

Page 35: ...ower supply box 7 Check the igniter connection at both the control module and the ODS pilot Connect if loose 8 Free igniter cable if pinched by any metal or tubing Keep igniter cable dry 9 Replace wir...

Page 36: ...ould be hand tight plus 1 4 to 1 2 turn You should not be able to loosen the thermocouple at the control valve with your hand Check the thermocouple terminal connec tion at the control module If it is...

Page 37: ...while the system is lighting under load The system will not function under 3 8 volts and batteries should be replaced if the voltage is under 4 0 volts 3 Check thermocouple terminal connection at the...

Page 38: ...uld work within 20 feet of the burner system If it does not re place the batteries in the remote and battery supply box Burner system shuts off Control module sounds 1 long beep 1 Control module is to...

Page 39: ...ator Slight smoke or odor during initial operation 1 Residues from manufacturing processes and logs curing 1 Problem will stop after a few hours of operation Heater produces a whistling noise when bur...

Page 40: ...ng Gas Connections Page 16 2 Replace control valve or gas control Gas odor during combustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning state ment at top of Page 1 Take a...

Page 41: ...TAGE FIBER LINER KITS Cat No H9076 Model SBLQ32SVF 32 Cat No H9077 Model SBLQ36SVF 36 PERIMETER TRIM ACCESSORY Cat No F1039 Model PT32 Black 32 Cat No F1040 Model PT32B Brass 32 Cat No F1041 Model PT3...

Page 42: ...8 44 18 17 25 20 35 34 12 12 13 39 38 28 7 6 5 1 10 14 12 23 24 3 4 37 26 32 11 9 Cat No Model F1199 VRT4032ZEN F1201 VRT4032ZEP F1203 VRT4036ZEN F1205 VRT4036ZEP WARNING Contact an IHP dealer to obt...

Page 43: ...71 Orifice 075 1 90 mm Middle 1 16 J3675 Orifice 0453 1 15 mm Middle 1 17 J8079 Orifice 0 028 0 711 mm Pan 1 17 F3135 Orifice 0 052 1 321 mm Pan 1 17 J3619 Orifice 0 038 0 965 mm Pan 1 18 J6127 Orific...

Page 44: ...26 Cord Power Supply 1 J3795 Wire Harness 1 J3658 Plate Warning 1 J6207 Kit Platinum Embers 1 J6208 Kit Glowing Embers rockwool 1 F2950 Remote Control ODS Touchscreen 1 F2957 ODS Spark Wire 1 J6585 Pl...

Page 45: ...5 ASM 32 Fireplace System Screen 1 J6776 ASM 36 Fireplace System Screen 1 7 J6492 Magnet Door Latch 2 8 J6778 Hood 32 Fireplace System 1 J6779 Hood 36 Fireplace System 1 9 J5458 Blower 1 10 J6783 Line...

Page 46: ...3 J6646 Log Left Middle 1 7 F2944 K2008 Log Right Middle 1 8 J6636 J6647 Log Rear Middle 1 9 J7518 J6648 Log Rear 1 10 J6637 J6637 Log Left Top 1 11 J6638 J6650 Log Middle Crossover 1 12 J6639 J6651 L...

Page 47: ...tural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c da...

Page 48: ...tributor for fireplace code information Printed in U S A 2016 Innovative Hearth Products P N 900719 00 REV C 04 2018 1508 Elm Hill Pike Suite 108 Nashville TN 37210 SuperiorFireplaces us com Record th...

Reviews: