background image

39

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. C  02/2018

Innovative Hearth Products

1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The product body, firebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 

against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 

Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 

replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 

pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The product body, firebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded 

from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a 

particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

10

/14

/20

15

Summary of Contents for DRT4036TEN

Page 1: ...appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchezàaucaninterrupteur Nepasvousservir des téléphones se trouvant dans le bâtiment où vous trouvez Sortez immédiatement de bâtiment Appelez immédiatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de ga...

Page 2: ...DURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla vidrio caliente es proveida con este...

Page 3: ...soient conscients du danger de brûlure encouru Les surfaces de votre foyer deviennent EXTRÊMEMENT CHAUDES La vitre située à l avant du foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact Tenez les enfants à l écart du foyer lorsqu il fonctionne Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d éviter qu ils ne so...

Page 4: ... fireplace must be installed with INNOVATIVE HEARTH PRODUCTS IHP vent pipe components and terminations NOTICE Decorative product not for use as a heating appliance This fireplace must be installed by a qualified certified or licensed service person It brings in fresh air for combustion through the outer pipe and combustion gases are exhausted through the inner pipe If the glass door assembly and v...

Page 5: ... viennent en contact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré po...

Page 6: ... UNIT SAFETY Continued Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be re quired due to excessive lint from carpeting bedding material etcetera It is imperative that control com partments burners andcirculatingairpassageways of the appliance be kept...

Page 7: ...y MA 02169 7471 PRODUCT IDENTIFICATION Figure 1 Direct Vent Fireplace Outer Glass Door Screen Barrier J7450 36 J7456 42 Log Set Flue Collar Top Spacer Spacer Nailing Flange Lower Door Control Cover Herringbone Brick Refractories Grate Based on CSA P 4 1 2015 SAFETY Continued the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 9 Do not use fireplace if any part has been ...

Page 8: ...peting vinyl tile or any combustible material other than wood it must be installed on a metal or wood panel extending the full width and depth of the fireplace see Figure 3 Page 9 Your fireplace is designed to be used in zero clearance installations Wall or framing material can be placed directly against any exterior surface on back sides or top of your fireplace except where standoff spacersarein...

Page 9: ... 44 1118 mm 36 Model 35 889 mm 36 Model 42 1067 mm 42 Model 41 1041 mm 36 Model 48 1219 mm 42 Model 44 1118 mm 42 Model 40 1016 mm 36 Model 30 762 mm 36 Model 48 1219 mm 42 Model 24 610 mm 42 Model 13 5 8 346 mm 42 Model Requires IHP 5 127 mm I D 8 203 mm O D Direct Vent Pipe 2 1 4 57 mm 6 3 4 171 mm 10 3 4 273 mm 36 Model 11 1 2 292 mm 42 Model 2 1 4 57 mm GAS LINE KNOCK OUT NAILING FLANGE NAILIN...

Page 10: ...ou can install noncombustible mantels at any height above the fireplace NOTE Noncombustible mantels may discolor Ensure adequate accessibility clearances for servicing and proper operation Figure 5 Framing Clearances with Outside Air Flex Duct Figure 5a Framing Dimensions Figure 6 Framing Clearances for Corner Installation Figure 7 Clearances for Combustible Mantels C B A D E F G 3 2 1 4 5 6 7 Wal...

Page 11: ...30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall exte...

Page 12: ...e and vent assembly must be vented directly to the outside The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance Each direct vent gas appliance must use a separate vent system Do not use common vent systems WARNING Vent pipe air space clearances to com bustibles are 1 on all sides except on the horizontal sections which require 2 clearances from the...

Page 13: ... exterior wall with provided wood screws see Figure 12 Page 14 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 13 Page 14 Carefully move fireplace with vent assembly attached toward wall and insert vent pipe into horizontal termination Pipe over...

Page 14: ...sing a venting configuration of only horizontal venting with no vertical run a 1 4 rise for every 12 of run toward the termination is required NOTICE Do not seal termination cap to vent pipe Cap must be removable for vent inspection and mainte nance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly installed and maintained ven...

Page 15: ... roof pitches Nearby trees adjoiningrooflines steeppitchedroofsandothersimilarfactors maycausepoordraftordown draftinginhighwinds Increasingvent height may solve this problem 7 Twist lock vent cap onto last section of vent pipe Venting with Two 90 Elbows Vertical V Horizontal H1 H2 feet meters feet meters 6 Min 1 829 8 Max 2 439 7 Min 2 134 10 Max 3 048 8 Min 2 439 15 Max 4 572 20 Max 6 096 20 Max...

Page 16: ...talling this fireplace at an elevation above 4500 feet check with local authorities PARTS LIST FOR VENTING KITS AND COMPONENTS IHP 5 8 Pipe Vent Kits IMPORTANT NOTE The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual Cat No Part No Description J2209 P58 6 6 Section Double Wall Pipe Galvanized J2201 P58 12 12 Sec...

Page 17: ...ssure to between 11 and 14 of W C pressure If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 21 Pointing the vent down protects it from freezing rain or sleet CAUTION Use only new black iron or steel pipe Internally tinnedcoppertubingmaybeusedincertain areas Check your local codes Use pipe of ...

Page 18: ... natural gas fireplace or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed 5 16 hex socket wrench or nut driver sealant resistant to propane LP gas not provided 1 Route flexible gas line provided by installer fro...

Page 19: ... glass door panel securely in place For replacement part information see Replacement Parts Page 31 CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed WARNING If firep...

Page 20: ...volcanic stone around base of burner Make sure burner ports are not covered see Figure 30 Page 21 4 Place ember flakes around front and sides of burner and on burner ports see Figure 31 Page 21 This will create the glowing ember appearance as the flame touches the ember flakes Do not block burner ports or pilot ports by overlapping ember flakes in one area It is not necessary to use all ember mate...

Page 21: ...to check for a leak Apply noncorrosive leak detection fluid to joints Bubbles forming show a leak Correct leaks at once CAUTION The gas supply shall be shut off prior to disconnecting the electrical power if any before proceeding with this installation CAUTION Use gloves when removing the log set burner module from your firebox Some metal edges may be sharp Use caution with log sets as logs are fr...

Page 22: ... system has power locate the learn button Figure 36 on the module Press and release the learn button There will be a beep sound from the module Then press any button on the remote transmitter Once the module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use BATTERY BACK UP This fireplace is equipped with a battery back up...

Page 23: ...interrupteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 2 Si une télécommande est utilisée pour contrôler le foyer nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur le boîtier de la...

Page 24: ...place burn ing logs will give off a paper burning smell Orange flame will also be present Open damper or window to vent smell This will only last a few hours 1 STOP Read the safety information in column 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position 4 Remove center brick control cover 5 Turn equipment shutoff valve clockwise to the OFF position see Fi...

Page 25: ... apagándola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien para quitar el polvo y aceite Pegue la eti...

Page 26: ...ary depending on installation type and weather conditions If the vent configuration is installed incorrectly flames will lift or ghost This can be dangerous Inspect flames after installation to ensure proper installation and performance Figure 40 shows a typical flame pattern If burner flame pattern differs from that described turn fireplace off see To Turn Off Gas to Appliance Page 24 see Trouble...

Page 27: ...UTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door Page 19 Vacuum all glass pieces with a shop vacuum CAUTION Do not vacuum if pieces are hot Use only glass door replacement intended for this fireplace see Replacement...

Page 28: ...debris and dirt inspect and clean any other possible obstructions 4 Contact your gas supplier to check pres sure 5 Have a qualified technician replace pilot line 6 Replace control valve Refer to Replace ment Parts Page 37 7 Check that main power is on and that all wire connections are made correctly to ignition model see Wiring Diagram Page 36 Check for 24 VAC at the sec ondary side of transformer...

Page 29: ...d 2 Burner flame holes blocked 3 Improper venting or excessive blockage 4 Excessive amounts of embers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots Dark residue on logs or inside of fireplace REMEDY 1 Locate and correct all leaks see Checking Gas Connections Page 18 2 Replace control valve 1 Take apart gas tubing and remove for...

Page 30: ...d Brick DRT4042TEN F1326 42 V Natural HER Red Brick DRT4042TEP F1327 42 V Natural STK Red Brick DRT4042TEN F1328 42 V Propane HER Red Brick DRT4042TEP F1329 42 V Propane STK Red Brick MODEL CATALOG NO DESCRIPTION DRT4036TEN F2280 36 V Natural HER White Brick DRT4036TEP F2281 36 V Natural STK White Brick DRT4036TEN F2282 36 V Propane HER White Brick DRT4036TEP F2283 36 V Propane STK White Brick DRT...

Page 31: ...2 Hearth Assembly 42 NG 1 J7653 Hearth Assembly 42 Propane LP 1 J7654 Hearth Assembly 36 NG High Altitude 1 J7655 Hearth Assembly 42 NG High Altitude 1 7 J7656 Grate 36 1 J7657 Grate 42 1 8 J7658 Door Latch 2 9 Firebox Leg 4 10 Firebox Bottom 1 11 J7659 Gasket 36 1 J7660 Gasket 42 1 12 J7661 Draft Diverter 1 13 Air Exchange 1 14 5 Gasket 1 15 5 Inner Connector 1 16 A E Insulation 1 17 Firebox Surr...

Page 32: ...TEN F2282 36 V Propane HER White Brick DRT4036TEP F2283 36 V Propane STK White Brick DRT4042TEN F2284 42 V Natural HER White Brick DRT4042TEP F2285 42 V Natural STK White Brick DRT4042TEN F2286 42 V Propane HER White Brick DRT4042TEP F2287 42 V Propane STK White Brick 24 1 3 2 4 4 5 5 6 7 8 9 10 11 12 13 14 15 16 18 19 17 20 13 13 21 22 23 25 26 27 27 WARNING Failure to position the parts in accor...

Page 33: ... 7 8 x11 4 OD 5 6 Log Burner Base 1 7 J7840 Pilot NG 1 J7841 Pilot Propane LP 1 8 Pilot Shield 1 9 J7696 Elbow Street 3 8 1 10 J7697 Front Orifice 47 NG 1 J7698 Front Orifice 56 Propane LP 1 J7699 Front Orifice 42 NG 1 J7698 Front Orifice 56 Propane LP 1 11 Base 1 12 J7700 Grommet SC 1 2 ID 1 1 16 OD 1 13 J7701 90 Brass Elbow 3 8 Tube x 3 8 NPT 3 14 J7720 Flextube Dormont 3 8 Dia x 11 1 15 J7723 F...

Page 34: ... Red Brick DRT4042TEP F1327 42 V Natural STK Red Brick DRT4042TEN F1328 42 V Propane HER Red Brick DRT4042TEP F1329 42 V Propane STK Red Brick MODEL CATALOG NO DESCRIPTION DRT4036TEN F2280 36 V Natural HER White Brick DRT4036TEP F2281 36 V Natural STK White Brick DRT4036TEN F2282 36 V Propane HER White Brick DRT4036TEP F2283 36 V Propane STK White Brick DRT4042TEN F2284 42 V Natural HER White Bric...

Page 35: ...Front Refractory 42 White 1 J7824 Center Front Refractory 36 White 1 6 J7825 Right Front Refractory 42 White 1 J7826 Right Front Refractory 36 White 1 D R T 4 0 4 2 H B o n e F 1 3 2 6 F 1 3 2 8 D R T 4 0 3 6 H B o n e F 1 3 2 2 F 1 3 2 4 D R T 4 0 4 2 S t a c k e d F 1 3 2 7 F 1 3 2 9 D R T 4 0 3 6 S t a c k e d F 1 3 2 3 F 1 3 2 5 KEY NO CATALOG NO DESCRIPTION QTY 1 J7791 Rear Refractory Herring...

Page 36: ...5 W C Front Orifice 42 Rear Orifice 44 DRT4036TEP Rating 31 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 W C Minimum Inlet Supply Pressure 11 W C Maximum Inlet Supply Pressure 13 W C Front Orifice 56 Rear Orifice 56 DRT4042TEP Rating 37 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 0 W C Minimum Inlet Supply Pressure 11 W C Max...

Page 37: ...SuperiorFireplaces us com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat propane LP gas supply might be low propane LP units only You may feel your gas pressure is too low If so contact your local gas supplier ACCESSORIES Purchase these appliance accessories from your local dealer If they can not suppl...

Page 38: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________...

Page 39: ... natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installatio...

Page 40: ... your local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126721 01 Rev G 03 2018 1769 East Lawrence Street Russellville AL 35654 P126721 01 SuperiorFireplaces us com Record the following important information about your fireplace Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name ...

Reviews: