SuperiorFireplaces.us.com
126718-01N
39
LIGHT ADJUSTMENT
• Transmits a light setting command to the control module to
adjust the light output level.
• Available settings are 0 (off) – 6 with a factory default of 0 (off).
• While in any mode of operation, press the LIGHT Zone to enter
Light Adjustment, then press the UP or DOWN buttons to raise
or lower the light output; press the MODE/SET Button or wait
for 15 seconds to accept the new setting.
• LCD Displays:
• When raising or lowering the light output level with the UP
or DOWN buttons, the light icon and light setting number
will flash in the LIGHT Zone.
CONTINUOUS PILOT OPERATION
• To activate or deactivate the Continuous Pilot Feature, press
and hold the MODE/SET and UP Buttons simultaneously for 5
seconds.
• LCD Display: When activated, CONT. PILOT will be displayed in
the MODE Zone.
CHILD-LOCK OPERATION
• Child-Lock operation prevents any user input to the transmitter.
No mode of operation or feature may be adjusted when Child-
Lock is activated. All automatic functions will continue normally.
• To activate or deactivate the Child-Lock feature, press and hold
the MODE/SET and DOWN Buttons simultaneously for 5 seconds.
• LCD Displays:
• When activated, the LOCK icon will appear in the MODE
Zone.
• If any touch-zone or button is pressed when activated, the
LCD backlight will illuminate and the LOCK icon will flash
for 5 seconds in the MODE Zone.
REMOTE CONTROL OPERATION
Continued
SENSOR SAFETY OVERRIDE
• Will only operate if the control is in MANUAL OFF mode.
• Press and hold the FLAME Zone and the UP Button simultane-
ously activate the sensor safety override feature.
• The module will ignore any sensor faults, continually emit an
igniter spark, and energize the PILOT operator output.
• When the buttons are released, the control will immediately
return to MANUAL OFF mode.
• LCD Display:
• When the Sensor Safety Override feature is activated, CONT.
PILOT will flash on the LCD screen.
COMMUNICATION SAFETY
• In manual ON and program modes of operation, the transmitter
will send a communication safety transmission every 15 - min-
utes. This signal is further processed by the ignition control
module to verify the transmitter is communicating properly.
SPECIFICATIONS
DRL4543TEN
• Rating: 35,000/22,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 5" w.c.
• Maximum Inlet Supply Pressure: 10.5" w.c.
• Orifice: #33
DRL4543TEP
• Rating: 33,000/24,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
• Maximum Inlet Supply Pressure: 13" w.c.
• Orifice: #50