12

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Power Vent Components

Locate the fireplace as instructed in this manual. Make the following modifications to add the com

-

ponents used with the Power Vent Kit. This kit may only be used in conjunction with Direct-Vent 

series electronic versions of Innovative Hearth Products Fireplaces. This installation must conform 

with local codes, or, in the absence of local codes, with the (USA) National Fuel Gas Code, ANSI 

Z223.1/NFPA 54 - latest edition, or (Canada) CAN/CGA-B149.1 - latest edition.

CAUTION: This power vent kit cannot be used with millivolt appliances. Use the kit only with 

the electronically controlled fireplaces listed for its use as shown in this document.

Item No.

Part 

Number

Description

Qty.

1

604187-01

Adaptor Assembly With Probe

1

2

601970-01

Vacuum Hose

1

3

601451-01

Termination Assembly

1

4

74L61

SV Termination Adaptor (SV4.5RCH)

1

5

102010-01

Strain Relief - 3/8"

1

6

H2246

Firestop Assembly (Horizontal)

1

7

102022-01

Hose Clamp - 11/32"

2

8

P-8-7102

Snap Bushing

1

9

 - 

Ring Terminal - #10

2

10

 - 

Insulated 1/4" Male Terminal

4

Step 3. INSTALL ThE VENT SYSTEM

General Information

These instructions should be used as a guide-

line and do not supersede local codes in any 

way. Install venting according to local codes, 

these instructions, and the (USA) National 

Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest 

edition, or (Canada) CAN/CGA-B149.1 - latest 

edition.

These fireplaces are designed, tested and 

listed for operation and installation only 

with Secure Vent

®

 (SV4.5) and Secure Flex

®

 

Direct-Vent System Components, manufac-

tured by Security Chimneys International. 

These approved vent system components are 

labeled for identification. DO NOT use any 

other manufacturer's vent components with 

these appliances.

Ensure clearances are in accordance with 

local installation codes and the requirements 

of the gas supplier.

Dégagement conforme aux codes 

d'installation locaux et aux exigences du 

foumisseunde gaz.

Use only approved venting components. See 

Approved Vent Components

 on 

Page 2

.

These fireplaces must be vented directly 

to the outside.

The vent system may not service multiple 

appliances, and must never be connected to a 

flue serving a separate solid fuel burning ap-

pliance. The vent pipe is tested to be run inside 

an enclosed wall (such as a chase). There is 

no requirement for inspection openings in the 

enclosing wall at any of the joints in the vent pipe. 

Venting System

With  the  appliance  secured  in  framing,  de

-

termine vent routing and identify the exterior 

termination location. The following sections 

describe horizontal (exterior wall) vent applica

-

tions. 

A list of approved venting components 

is shown on 

Page 28

.

2

1

3

4

6

5

7

8

Figure 11 - Power Vent Kit Components

8

9

INNOVATIVE HEARTH PRODUCTS  •  POWER VENT DV GAS FIREPLACES  (DRT63__TYN / DRC63__TYN)  •  INSTALLATION INSTRUCTIONS

Summary of Contents for DRC6345TYNDRC6340TYN

Page 1: ...E CHAUDE PEUT CAUSER DES BR LURES LAISSER REFROIDIR LA SURFACE VITR E AVANT D Y TOUCHER NE PERMETTEZ JAMAIS UN ENFANT DE TOUCHER LA SURFACE VITR E EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNC...

Page 2: ...peration Page 21 Step 9 Installing Logs Page 22 Step 10 Install Remove Glass Door Assembly Page 24 Step11 Burner Adjustments Page 24 Finishing Requirements Page 26 Step 12 Attaching Safety in Operatio...

Page 3: ...WER VENT DV GAS FIREPLACES DRT63__TYN DRC63__TYN INSTALLATION INSTRUCTIONS WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this...

Page 4: ...let and OUT for the manifold side see Figure 1 Orifice Sizes Sea Level To High Altitude These appliances are tested and approved for installation at elevations of 0 4500 ft 0 1370 m above sea level us...

Page 5: ...actured home in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition LOCATION In selecting the location the aesthetic and function...

Page 6: ...ead combustible projection of 2 1 2 64 mm or less see Figure 3 For projections exceeding 2 1 2 64 mm see Figure 3 For additional vent location restrictions refer to Figure 4 on Page 7 INNOVATIVE HEART...

Page 7: ...s 10 000 BTU hr 3kW and 100 000 BTU hr 30kW 36 91 cm for appliances 100 000 BTU hr 30kW 6 15 2 cm for appliances 10 000 BTU hr 3kW 9 23 cm for appliances 10 000 BTU hr 3kW and 50 000 BTU hr 15kW 12 30...

Page 8: ...rated 175 F or higher on the underside of the mantel MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sid...

Page 9: ...low for a minimum clearance to combustible framing members as shown in Table 5 on Page 8 If the appliance is to be elevated above floor level a solid continuous platform must be constructed below the...

Page 10: ...el No A B C D E F G H J 40 in in 50 5 8 37 1 4 42 7 8 25 5 16 34 37 5 8 33 3 32 29 9 32 34 3 4 mm 1286 946 1089 643 864 956 840 744 883 45 in in 56 11 16 42 1 4 47 7 8 28 3 8 40 1 8 43 5 8 38 3 32 34...

Page 11: ...8 59 1 8 41 7 8 mm 1286 2124 1502 1064 45 in in 56 3 4 89 7 8 63 1 2 44 7 8 mm 1441 2283 1613 1140 C Back wall of chase enclosure including any finishing materials D A B Figure 9 Corner Framing with...

Page 12: ...Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or Canada CAN CGA B149 1 latest edition These fireplaces are designed tested and listed for operation and installation only with Secure Vent SV4 5 and...

Page 13: ...1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2 4 1 0 0 1 0 1 2 1 5 1 1 5 5 2 6 2 4 0 0 0 0 1 1 1 1 5 0 2 5 5 7 3 3 4 0 2 0 1 1 1 4 1 1 3 5 5 2 4 4 0 2...

Page 14: ...x 1 2 screw may be used at the joint butitisnotrequiredasthepipewillsecurely lock when twisted C Attachventcomponentstoeachother Other vent sections may be added to the previously installedsectioninac...

Page 15: ...Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Maintain the horizontal inclined run in a straight slightly elevated plane approximately 1 4 per foot 20 mm...

Page 16: ...vent sections in horizontal inclined run as described in Step E Install support straps every three feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape see Figure 16 on P...

Page 17: ...TE Centerline of Vent Piping is NOT the Same as the Centerline of the Frame Opening 6 to 48 Vent Section Telescopic vent section Elbow or Appliance Collar Base of Appliance 3 76 mm 1 25 4 mm Adaptor S...

Page 18: ...fireplace to the newly installed junction box near the termination Ensure the cable is safety plated to prevent damage from framing nails and finish drywall screws Route it into the lower control com...

Page 19: ...n it to fit within the junction box cover WARNING Crimp connectors may be used on stranded cables such as SJOT cable only Solid wire Romex must be connected per the National Electric Code NEC 70 lates...

Page 20: ...t only be replaced as a complete unit as provided by the manufacturer Do not attempt to replace broken cracked or chipped glass separately INNOVATIVE HEARTH PRODUCTS POWER VENT DV GAS FIREPLACES DRT63...

Page 21: ...ed above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Re install the access plate making certain the gasket has not been damaged Figure 29 Fireplace R...

Page 22: ...able and attractive flame pattern Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion sooting and poor flame quality Logs get very h...

Page 23: ...e And Push It Towards The Rear 3 2 4 1 6 5 7 Log Number Description 1 Log Center 2 Log Rear 3 Log Center Left 4 Log Center Right 5 Log Rear Top 6 Log Front Left 7 Log Front Center Table 6 Log Set Alig...

Page 24: ...st be replaced prior to operating the appliance AVERTISSEMENT Tout cran ou pro tecteurretir pourpermettrel entretiende l appareil doit tre remis en place avant de mettre l appareil en marche Installin...

Page 25: ...nstallation Leave the ON REMOTE OFF wall switch in the REMOTE position and turn the remote switch OFF Use the remote to adjust the flame height as desired CAUTION Soot will be produced if the air shut...

Page 26: ...ed there are two methods of installation Combustible or noncombustible finish material may abut the front face of the fireplace and the floor panel see Figure 45 Combustible or noncombustible finish m...

Page 27: ...ipalement parl e dans la r sidence du propri taire En cas de doute collez l tiquette en anglais 2 Rep rezlat l commandeetnettoyez lasoigneuse ment pour liminer la poussi re et les traces degraisseoud...

Page 28: ...Section 77L72 SV4 5L24 24 610mm Vent Section 77L73 SV4 5L36 36 914mm Vent Section 77L74 SV4 5L48 48 1219mm Vent Section 77L75 SV4 5LA Telescopic Section 77L76 SV4 5E45 45 Degree Elbow 77L77 SV4 5E90 9...