background image

Superiorfireplaces.US.com

126745-01D

7

PRE-INSTALLATION PREPARATION 

CLEARANCES

Minimum clearances to combustibles are:
Ceiling                                                                                40" min.
Top of Spacers                                                                     0" min.
Back and Sides of Outer Surround                                       0" min.
Drywall to Sides of Front Face (Nailing Flanges)                  0" min.

“B” Vent Surfaces                                                                1" min.
Ceiling to Opening                                                              42" min.
Floor                                                                                     0" min.
Perpendicular Wall                                                       See Figure 6

 CAUTION: Do not block required air spaces with 

insulation or any other material. Do not obstruct ef-

fective opening of appliance with any type of facing 

material.

Figure 3 - Minimum Clearances (Top View)

0 cm/

po

0 cm/po

Clearance

Nailing 

Flange

Front Face

Left Side Surround

Back

Drywall

2 x 4 Stud

*

*

*

*

42" (10.67 cm)

Min. Clearance

from Opening to 

Ceiling

0" Clearance

Ceiling

1" (2.5 cm) Min.

Clearance to 

"B" Vent's Outer Pipe

Required

Air Spaces 

are Indicated 

with an "*".  

Do Not 

Pack with 

Insulation or 

Any Other 

Material

DO NOT BLOCK

OR OBSTRUCT

OPENINGS

0" Clearance 

to Wood or 

Noncombustible

Flooring

Figure 4 - Minimum Clearances (Front View)

MANTEL CLEARANCES AND WALL DETAILS

A combustible mantle shelf maybe installed a maximum 12" (22.9 

cm) from the wall. Figures 5 and 6 show the minimum allowable 

distances from various combustible mantle components in relation 

to the fireplace opening.

Spacer

3" (7.6 cm)

1

/

2

(3.8 cm) Max.

8" (20.3 cm)

6" (15.2 cm)

13" (33 cm)

12"

(22.9 cm)

Combustible
Materials

Header

Figure 5 - Mantel Clearances - Side View (Cross Section)

1

/

2

" (3.8 cm)

Max.

3" (7.6 cm)

Max.

6" (15.2 cm)

Max.

9"

(22.86 cm)

12"

(30.48 cm)

Outer Surround

Combustible
Material May
Be Used

TOP VIEW

SAFE
ZONE

Perpendicular
Wall

Figure 6 - Side Clearances - Top View (Cross Section)

Summary of Contents for BRT2000 Series

Page 1: ...e risque d incindie ou d explosion ou pour viter tout dommage mat riel toute blessure ou la mort Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other...

Page 2: ...lation and operational procedures For assis tance or additional information consult a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanent...

Page 3: ...he fireplace in high traffic areas in windy or drafty areas 5 This fireplace reaches high temperatures Keep children and adults away from hot surfaces to avoid burns or clothing igni tion Fireplace wi...

Page 4: ...an the type of gas approved for use in this gas appliance Installation must conform with local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 This fireplace...

Page 5: ...PROPANE LP Max Input Rating 15 000 Btu Hr 25 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13...

Page 6: ...d or at a premium and since the space required to enclose the appliance would be located beyond an outside wall this would also reduce the cutting of joists roof rafters and such Check local codes for...

Page 7: ...ling 0 Clearance Ceiling 1 2 5 cm Min Clearance to B Vent s Outer Pipe Required Air Spaces are Indicated with an Do Not Pack with Insulation or Any Other Material DO NOT BLOCK OR OBSTRUCT OPENINGS 0 C...

Page 8: ...o cover any openings Prepare the incom ing gas line with Teflon tape or pipe joint compound and hookup incoming gas line to flexible gas line PRE INSTALLATION PREPARATION Continued Note If 1 2 NPT bla...

Page 9: ...t above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT...

Page 10: ...lateral length must exceed 75 then the system must be sized in accordance with the Category I venting tables Example 2 shows a multiple offset each at 45 of inclination Multiple offsets are permitted...

Page 11: ...8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Ove...

Page 12: ...e s gas sup ply system You may consider installing an extra gas shutoff valve outside the appliance s enclosure check with local codes where it can be accessed more conveniently with a key through a w...

Page 13: ...nstallation is completed After ensuring that the gas valve is on apply a non corrosive leak detection solution to all connections and joints If bubbles appear leaks can be detected and corrected Do no...

Page 14: ...under the lower grate members to allow air to flow see Figure 21 LOG PLACEMENT FOR BRT2032TMN MODEL 1 Place front log onto front of grate sliding log all the way forward against grate fingers see Fig...

Page 15: ...ace top of log 4 into notch on log 1 Rest log 4 on the center of grate as shown in Figure 26 5 Place top of log 5 into notch on top right of log 1 see Figure 26 Rest log 5 between two middle grate fin...

Page 16: ...ge of firebox opening 4 Tilt door assembly fully vertical until outer pivot pin snaps into mounting hole in upper spring clip see Figure 30 5 Once top and bottom pins are secured unfold door into clos...

Page 17: ...ly Opened Door Figure 32 Removing Glass Doors Spring Clip Press Spring Clip to Release Pivot Pin Remove Bottom Pin From Pivot Plate While Sliding Door Out of the Upper Track Pivot Plate Fold Bi Fold D...

Page 18: ...ndicator Gas Control Knob Pilot Adjustment Screw LIGHTING INSTRUCTIONS NOTICE During initial operation of new fireplace burning logs will give off a paper burning smell Orange flame will also be prese...

Page 19: ...l knob to ON position Slide the selector switch to the REMOTE position Note Burner may light if hand held remote ON button was on when selector switch was last turned off You can now turn burner on an...

Page 20: ...nce off see To Turn Off Gas to Appliance page 19 see Troubleshooting page 21 Figure 36 Typical Flame Pattern BRT2332TMN BRT2532TMN Models BRT2032TMN Model WARNING Installation and repair should be don...

Page 21: ...ossible obstructions 4 Contact your gas supplier 5 Refer to section on pilot lighting 6 Have a qualified technician replace pilot line 7 Replace regulator valve see Accessories page 23 1 Check wiring...

Page 22: ...tween control valve and burner 2 Gas leak See Warning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive...

Page 23: ...of your fireplace ready You can also visit our web site at IHP US com ACCESSORIES Purchase these accessories from your local dealer If they can not supply these accessories call IHP at 1 800 655 2008...

Page 24: ...ces US com 126745 01D 24 PARTS MODEL BRT2032TMN 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 36 14 12 13 23 16 31 32 20 32 38 39 40 40 4 34 35 21 17 8 10 18 5 5 2 22 1 3 37 42 11 11 9 CATALOG NO MODEL F...

Page 25: ...ebox Face 1 21 108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 109797 01 Grate Assembly 1 24 109107 01 Burner Assembly see page 30 1 25 14512 Gas Control Valve Natural Gas 1 14513 Gas Con...

Page 26: ...6 PARTS BRT2332TMN AND BRT2532TMN MODELS 33 43 41 15 19 6 7 24 14 30 26 29 25 28 27 18 14 12 13 23 10 36 9 36 35 16 31 32 20 32 38 39 40 40 4 34 21 17 8 46 45 44 2 22 1 3 44 11 37 42 5 5 CATALOG NO MO...

Page 27: ...1 21 108412 01 Smoke Deflector 1 22 Fireplace Top Insulation 1 23 109040 01 Grate Assembly 1 24 108712 03 Burner Assembly see page 30 1 25 14512 Gas Control Valve Natural Gas 1 14513 Gas Control Valv...

Page 28: ...2 PARTS BURNER ASSEMBLY This list contains replaceable parts used in your fireplace When ordering parts follow the instructions listed under Replacement Parts on page 23 of this manual KEY NO PART NO...

Page 29: ...5 KEY NO PART NO DESCRIPTION QTY 109100 02 Log Set 1 109421 01 Rear Log 1 2 109420 01 Front Right Log 1 3 108723 01 Front Left Log 1 4 108722 01 Top Y Log 1 5 108720 01 Top Log 1 WIRING DIAGRAM DO NOT...

Page 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in...

Page 32: ...Printed in U S A 2013 IHP LLC P N 126745 01 Rev D 10 2014 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 IHP US com KEEP THIS WARRANTY Model located on product or identification tag _...

Reviews: