Introduction - Save These Instructions

Intelligent Microprocessor Control

The SBK350 STABILINE Uninterruptible Power Supply is an advanced line-

interactive UPS based on microprocessor control. This means that it operates with 

the newest technology, high performance and powerful function. 

The SBK350 provides pure, reliable AC power to the critical loads - protecting 
them from utility power blackout, swells, sags, surges and interference. The loads 

could include sensitive medical instruments, small servers, workstations, personal 

computers, telecommunication systems, and industrial automation equipment. 
Under normal power conditions, the line-interactive design enables the system to 
adjust and filter power fluctuations continuously and automatically.  In the event of a 
power failure, it can provide immediate back-up power from the battery without any 

interruption. Complete transference will be achieved within 4 milliseconds, with no 
interruption. 

When the utility power is connected, the UPS charger will work automatically even 
when the power switch is OFF. Furthermore, in order to save the battery energy, the 
UPS can be set to turn itself OFF under BACKUP MODE if none of the connected 

loads are operating.

Advanced Battery Management

The visual and audible indicators of the SBK350 present the UPS’s status. A self-test 
function lets the UPS detect a weak battery before it is put into service. The UPS 
normally performs a self-test at power up and a manual self-test function can be 
performed via the ON/OFF power switch

1. Presentation

The UPS is a line interactive uninterruptible power system (UPS). When utility input 

is normal, the UPS will provide surge protection and energy to charge the internal 

battery. If the utility input is abnormal, the UPS can supply AC power to the loads 

immediately.
(1). Utilizing microprocessor based controls, it will minimize the dependency on 

hardware,  ...

maximize system flexibility and optimizes the assurance of reliability.

(2). Automatic frequency selection to match with utility power.
(3). High-grade battery charger to prolong battery’s life and fully charge the battery.
(4). Overload protection both in line and battery mode.

Summary of Contents for STABILINE

Page 1: ...xpect exceptional performance The unit is built to the highest standards for your complete satisfaction To assure many years of uninterrupted service please read and save this Manual The Manual is a g...

Page 2: ...Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting or disconnecting battery terminals Ser...

Page 3: ...ted the UPS charger will work automatically even when the power switch is OFF Furthermore in order to save the battery energy the UPS can be set to turn itself OFF under BACKUP MODE if none of the con...

Page 4: ...MODE The LED indicator flashes rapidly about once every 0 5 second when the loads connected to the UPS exceed the UPS s capacity OVERLOAD 1 2 Rear Panel AC INPUT POWER Review the utility input power...

Page 5: ...each load to be UPS protected such as a personal computer to the UPS receptacles One convenience receptacle is provided for a non UP protected load CAUTION Never connect a laser printer or plotter to...

Page 6: ...udible Alarms 4 1 BACKUP slow alarm When the UPS is working in BACKUP mode the UPS will emit an audible alarm The alarm stops when the UPS returns to LINE MODE operation ATTENTION The alarm for BACKUP...

Page 7: ...MODE 5 Maintenance and Storage 5 1 Maintenance 5 1 1 Keep the unit clean and vacuum the ventilation intake periodically 5 1 2 Wipe with soft damp cloth 5 1 3 Check for loose and bad connections month...

Page 8: ...t Present Battery Mode and Overload 110 115 120 VAC Model SBK350 BATTERY GENERAL SPECIFICATIONS 0 C to 35 C 32 F to 95 F 15 3 lbs 6 9 kg UL cUL FCC Class A 6 Foot Cord with NEMA 5 15P Plug 12 VDC 25 o...

Reviews: