INSTALLATION GUIDELINES
Remove the bin carton and tip the bin on its back to remove the skid and attach the bin legs.
Secure the machine on top of the bin or dispenser.
Attach the ice machine to the bin with the mounting straps provided with the bin or dispenser.
Insure that the back of the ice machine is flush with the back of the bin. Proper functioning of the
bin door requires the bin door, when it is opened, to be in a stable position.
If the ice machine is too far forward on the bin, the opened door may not be stable, resulting in an
unexpected closing of the bin door. If the ice machine is to be mounted on a bin or dispenser
other than a Supera, refer to the manufacturer instructions for machine mounting. Supera will not
be responsible for damage or injury that results from unexpected closing of the bin door as a
result of the ice machine being too far forward on the bin.
Important!
A water filtration system should be installed with all ice machines. Check the filter manufacturer's
instructions for proper installation.
All water supply lines must be installed per local codes. Use 1/4 inch O.D. minimum on air cooled
machines. On water cooled machines 3/8 inch O.D.
minimum tubing must be run to the condenser. The
water supply for the float can “T” off from the
condenser line using 1/4 inch
O.D. minimum tubing. Make 2 coils of extra tubing so
that the machine can be pulled away from the wall if
service is needed.
All drain lines must be installed per local codes. The
purge drain should be a minimum of 5/8 inch O.D.
tubing. The condenser drain on water cooled units
should be 3/8 inch O.D. minimum. The drain line
fittings on Supera bins are 3/4 FPT. The bin drain
should be a minimum of 3/4 inch O.D. Cold water
drains should be insulated to prevent condensation
from forming.
Warning!
Do not apply heat directly to the back of bin as
damage may occur to plastic parts.
Do not over tighten the purge drain fitting as
damage may occur to plastic parts.
Connect power supply to the terminal block in the
control box or at the rear junction box if equipped.
Ensure the machine is level within 1/8 inch in all
directions.
Remove any shipping or packaging material.
Once the machine has been installed, follow the start-
up procedures.
© Supera
September 2015
5