2-22
X
10SLM-F/X10SLL-F/X10SLL-SF/X10SLL-S User’s Manual
Power Button
OH/Fan Fail
1
NIC1 Activity LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
UID Switch
Blue LED
Ground
Ground
19
20
3.3V
X
Ground
NMI
X
NIC2 Activity LED
3.3V Stby
3.3V Stby
A. HDD LED
B. NIC1 LED
C. NIC2 LED
A
B
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. Attach a
cable here to indicate HDD activ-
ity. See the table on the right for pin
definitions.
HDD LED
Pin Definitions (JF1)
Pin# Definition
13
3.3V Stby/UID_SW
14
HD Active
NIC1/NIC2
The NIC (Network Interface Control
-
ler) LED connection for LAN Port 1
is located on pins 11 and 12 of JF1,
and the LED connection for LAN Port
2 is on Pins 9 and 10. Attach the NIC
LED cables to the LED indicators
mentioned above to display network
activity. Refer to the layout below for
the locations of NIC LED indicators.
LAN1/2 LED
Pin Definitions (JF1)
Pin# Definition
9
3.3V Stby
10
NIC 2 Activity LED
11
3.3V Stby
12
NIC 1 Activity LED
C
FAN2
JP9
SW1
T-SGPIO1
JSTBY1
JIPMB1
JPW2
JSD1
LED3
LED2
JD1
LED5
LED1
JPI2C1
BT1
JPW1
JTPM1
FANA FAN3
FAN1
FAN2
FAN4
JPL1
JPL2
JPME2
JWD1
JPG1
JBR1
JPME1
J19 J18
J7
JVR1
JI2C1
JI2C2
JOH1
JP8
JL1
JP2
JP1
JP7
USB 3.0-0
USB 3.0-1
USB 3.0-2/3
VGA
LAN2
LAN1
USB4/5
USB6/7
IPMI_LAN
COM2
COM1
P1-DIMMB1
P1-DIMMB2
P1-DIMMA2
P1-DIMMA1
PCH SLOT4 PCI-E 2.0 X4(IN X8)
CPU SLOT5 PCI-E 3.0 X8
CPU SLOT6 PCI-E 3.0 X8(IN X16)
JF1
I-SATA4
I-SATA3
I-SATA5
I-SATA2
I-SATA1
I-SATA0
USB8/9
JRK1
T-SGPIO2
JPB1
X10SLM-F/X10SLL(-F/SF/S)
Rev. 1.02
BMC FW
FP Control
PCH
BMC
CTRL
CPU
SP1
LED4
IPMI Code
BAR Code
MAC Code
JBT1
BIOS