POSITIVE PRESSURE VENTILATOR
5
V18-BL PPV User Guide
Revised 9-2019
4.
Before Operating Ventilator
•
This ventilator has been designed to work best with either the Milwaukee M18 REDLITHIUM High Output XC8.0Ah or HD12.0 batteries.
•
This ventilator will work with any M18 battery from the Milwaukee brand.
•
A complete inspection of the ventilator should be made prior to operation.
•
Check all threaded fasteners for proper tightness.
•
Check ventilator inlet and outlet guards for obstructions. Check and remove from immediate surrounding area any objects that could be drawn into the
ventilator intake.
•
Replace damaged or missing guards before operating ventilator.
•
Never store or carry the battery pack so that metal objects can contact exposed battery terminals. Transporting batteries can possibly cause fires if the
battery terminals contact loose nails, screws, keys, hand tools and the like.
•
If using shore or mains power:
o
Never use power cords with frayed, cut, or brittle insulation.
o
Inspect power cord plug for proper connections to the ground fault interrupter circuit.
Airflow vs Setback
11,000
10,000
9,000
8,000
7,000
9,209
10,230
MAXIMUM
AIRFLOW
↓
10,103
8,873
8,131
7,854
10º
15º
20º
25º
30º
0
21 ft
18 ft
15 ft
12 ft
9 ft
6 ft
3 ft
0
6.5 m
5.5 m
4.5 m
3.6 m
2.7 m
1.8 m
1 m
Setback (ft, m)
A
irf
lo
w
(C
FM
)
6,000
5,000
4,000
3,000
2,000
1,000
5º