Super Systems DPC2500 Product Manual Download Page 9

 Super Systems Inc.  Page 9 3/25/2021 

 

Super Systems Inc. 

USA Office 

Corporate Headquarters: 

7205 Edington Drive 

Shipping Address: 

7245 Edington Drive 

Cincinnati, OH 45249 

Phone: (513) 772-0060 

http://www.supersystems.com 

Super Systems Europe 

Unit E, Tyburn Trading Estate, 

Ashold Farm Road, Birmingham 

B24 9QG 

UNITED KINGDOM 

Phone: +44 (0) 121 306 5180 

http://www.supersystemseurope.com 

Super Systems México 

Sistemas Superiores Integrales S de RL de CV 

Acceso IV No. 31 Int. H Parque Industrial 

Benito Juarez 

C.P. 76120 Queretaro, Qro. 

Phone: +52 442 210 2459 

http://www.supersystems.com.mx 

Super Systems China 

No. 369 XianXia Road 

Room 703 

Shanghai, CHINA 

200336 

Phone: +86 21 5206 5701/2 

http://www.supersystems.cn

 

Super Systems India Pvt. Ltd. 

A-26 Mezzanine Floor, FIEE Complex, 

Okhla Indl. Area, Phase – 2 

New Delhi, India  110 020 

Phone: +91 11 41050097 

http://www.supersystemsindia.com 

 

 

Summary of Contents for DPC2500

Page 1: ...500 as your continuous Dew Point Analyzer UNPACKING Carefully unpack the Model DPC2500 Dew Point Analyzer If there are any signs of shipping damage notify SSi and the shipper If a camera is available...

Page 2: ...tems Inc Page 2 3 25 2021 Table 0f contents INTRODUCTION 1 UNPACKING 1 NOTE 1 OPERATION 3 HOW IT WORKS 3 WHAT IT MEASURES 3 FACTORY CALIBRATION 5 FIELD CALIBRATION 5 FIELD CALIBRATION CONTINUED 6 SPAR...

Page 3: ...ctric ceramic that varies its electrical capacitance with changes in relative humidity The dual RH temperature sensor is mounted in a short probe which in turn is installed in a T fitting that allows...

Page 4: ...uivalent is clean and functional for generator operation you should turn the pump toggle switch OFF Maintain at least a 1 5 2 0 SCFH atmosphere flow through the analyzer Remember that the sample line...

Page 5: ...his kit consists of two bottles of saturated salt solution in which each bottle generates a precise relative humidity One bottle is 11 3 R H and the other 75 3 R H These two calibration points are alr...

Page 6: ...he bottle Step No 6 Turn the unit ON Step No 7 Press the CAL BUTTON and the SPAN BUTTON simultaneously Release both buttons See drawing Page 5 NOTE Do not be concerned if the front panel display does...

Page 7: ...0 continuous dew point analyzer Product manual SPARE PARTS Description Part No Factory Calibration 13045 Sample Pump 31401 Filter 37048 Replacement filter element 31027 Flow meter 36027 Microprocessor...

Page 8: ...n History Rev Description Date Initial Release 11 01 2000 A Added Revision History Page 07 09 2001 B SSi Address Update General Update 04 13 2005 C Corrected terminal block wiring chart 3 18 2020 D Ad...

Page 9: ...121 306 5180 http www supersystemseurope com Super Systems M xico Sistemas Superiores Integrales S de RL de CV Acceso IV No 31 Int H Parque Industrial Benito Juarez C P 76120 Queretaro Qro Phone 52 44...

Reviews: