background image

                                                                                   

7/22

 

USAGE

 

OF

 

GENERATOR

 

 

 

1.

 

Ground

 

Terminal

 

The

 

generator

 

ground

 

terminal

 

is

 

connected

 

to

 

the

 

frame

 

of

 

the

 

generator,

 

the

 

metal

 

non

current

 

carrying

 

parts

 

of

 

the

 

generator,

 

and

 

the

 

ground

 

terminals

 

of

 

each

 

receptacle.

 

Before

 

using

 

the

 

ground

 

terminal,

 

consult

 

a

 

qualified

 

electrician,

 

electrical

 

inspector

 

or

 

local

 

agency

 

having

 

jurisdiction

 

for

 

local

 

codes

 

or

 

ordinances

 

that

 

apply

 

to

 

the

 

intended

 

use

 

of

 

the

 

generator.

 

 
 
 
 
 
 
 
 
 
 
 
 

2.

 

Circuit

 

Breaker

 

The

 

circuit

 

breaker

 

will

 

automatically

 

switch

 

OFF

 

if

 

there

 

is

 

a

 

short

 

circuit

 

or

 

a

 

significant

 

overload

 

of

 

the

 

generator

 

at

 

the

 

receptacle.

 

If

 

the

 

circuit

 

breaker

 

is

 

switched

 

OFF

 

automatically,

 

check

 

that

 

the

 

appliance

 

is

 

working

 

properly

 

and

 

does

 

not

 

exceed

 

the

 

rated

 

load

 

capacity

 

of

 

the

 

circuit

 

before

 

switching

 

the

 

circuit

 

breaker

 

ON

 

again.

 

The

 

circuit

 

breaker

 

may

 

be

 

used

 

to

 

switch

 

the

 

generator

 

power

 

ON

 

or

 

OFF.

 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SP3500WS

Page 1: ...1 22 GASOLINE GENERATING SET web www superpowergenerator com E mail verahardworking hotmail com Owner s Manual...

Page 2: ...s as needed 4 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry and long hair can be caught in movi...

Page 3: ...d It will do the job better and more safely at the rate for which it was intended Do not modify this generator and do not use this generator for a purpose for which it was not intended INSTALLATION PR...

Page 4: ...gine Key can be removed inserted ON To run the engine after starting START To start the engine by turning the starter motor 2 The fuel valve is located between the fuel tank and carburetor When the va...

Page 5: ...the starter motor Return the key to the ON position once the engine has started Do not use the starter for more than 5 seconds at a time If the engine fails to start release the switch and wait 10 sec...

Page 6: ...close circuit breaker 2 Turn the engine switch to OFF position 3 Turn the fuel valve lever to the OFF position When the engine is not in use leave the fuel valve lever in the OFF position to prevent c...

Page 7: ...jurisdiction for local codes or ordinances that apply to the intended use of the generator 2 Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a signific...

Page 8: ...sure that the voltmeter indicates the specified voltage Do not exceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker to switch OFF reduce the...

Page 9: ...l is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oil level BEFORE EACH USE with the gen...

Page 10: ...xtremely flammable and is explosive under certain conditions Refuel in a well ventilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or...

Page 11: ...cable end A battery can explode if you do not follow the correct procedure seriously injuring anyone nearby Keep all sparks open flames and smoking materials away from the battery 1 Connect the batter...

Page 12: ...CE Periodic maintenance and adjustment is necessary to keep the generator in good operating condition Perform the service and inspection at the intervals shown in the maintenance schedule below Exhaus...

Page 13: ...onged periods Although this is unlikely unless you hands used oil on a daily basis it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handing used oil Pl...

Page 14: ...the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element 4 Reinstall the air cleaner element and the cover Fuel Sediment Cup Cleaning The sediment...

Page 15: ...er engine operation the spark plug must be properly gapped and free of deposits If the engine has been running the muffler will be very hot Be careful not to touch the muffler 1 Remove the spark plug...

Page 16: ...n improperly tightened spark plug can become very hot and could damage the engine Never use spark plugs which have an improper heat range Use only the recommended spark plugs or equivalent TRANSPORTIN...

Page 17: ...y loosening the drain screw Drain the gasoline into a suitable container Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a well ventilated area with the...

Page 18: ...18 22...

Page 19: ...may ignite 2 Remove the spark plug and install the spark plug in the plug cap YES 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap NO To check 1...

Page 20: ...cuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or equipment for any defects Take the generator to an authorized generator dealer Replace the electrical appliance or equi...

Page 21: ...21 22 WIRING DIAGRAM Starting with hand or Electric start...

Page 22: ...22 22 Starting with hand start...

Reviews: