background image

                                                                                   

13/22

 

Fuel

 

line

 

Check

 

(Replace

 

if

 

necessary)

 

Every

 

2

 

years

   

 

(1)

 

Service

 

more

 

frequently

 

when

 

used

 

in

 

dusty

 

areas.

 

(2)

 

For

 

professional

 

commercial

 

use,

 

log

 

hours

 

of

 

operation

 

to

 

determine

 

proper

 

maintenance

 

intervals.

 

Engine

 

oil

 

change

 

Drain

 

the

 

oil

 

while

 

the

 

engine

 

is

 

warm

 

to

 

assure

 

rapid

 

and

 

complete

 

draining.

 

1.

 

Remove

 

the

 

drain

 

plug

 

and

 

sealing

 

washer,

 

remove

 

the

 

oil

 

filler

 

cap,

 

and

 

drain

 

the

 

oil.

 

2.

 

Reinstall

 

the

 

drain

 

plug

 

and

 

sealing

 

washer.

 

Tighten

 

the

 

plug

 

securely.

 

3.

 

Refill

 

with

 

the

 

recommended

 

oil

 

and

 

check

 

the

 

oil

 

level.

 

Oil

 

capacity:

 

0.6L

 

 
 
 
 
 
 
 
 
 
 

 

 

Used

 

motor

 

oil

 

may

 

cause

 

skin

 

cancer

 

if

 

repeatedly

 

left

 

in

 

contact

 

with

 

the

 

skin

 

for

 

prolonged

 

periods.

 

Although

 

this

 

is

 

unlikely

 

unless

 

you

 

hands

 

used

 

oil

 

on

 

a

 

daily

 

basis,

 

it

 

is

 

still

 

advisable

 

to

 

thoroughly

 

wash

 

your

 

hands

 

with

 

soap

 

and

 

water

 

as

 

soon

 

as

 

possible

 

after

 

handing

 

used

 

oil.

 

Please

 

dispose

 

of

 

used

 

motor

 

oil

 

in

 

a

 

manner

 

that

 

is

 

compatible

 

with

 

the

 

environment.

 

We

 

suggest

 

you

 

take

 

it

 

in

 

a

 

sealed

 

container

 

to

 

your

 

local

 

service

 

station

 

or

 

recycling

 

center

 

for

 

reclamation.

 

Do

 

not

 

throw

 

it

 

in

 

the

 

trash,

 

pour

 

it

 

on

 

the

 

ground,

 

or

 

down

 

a

 

drain.

 

Air

 

cleaner

 

service

 

A

 

dirty

 

air

 

cleaner

 

will

 

restrict

 

air

 

flow

 

to

 

the

 

carburetor.

 

To

 

prevent

 

carburetor

 

malfunction,

 

service

 

the

 

air

 

cleaner

 

regularly.

 

Service

 

more

 

frequently

 

when

 

operating

 

the

 

generator

 

in

 

extremely

 

dusty

 

areas.

 

 

Using

 

gasoline

 

or

 

flammable

 

solvent

 

to

 

clean

 

the

 

fitter

 

element

 

can

 

cause

 

a

 

fire

 

or

 

explosion.

 

Use

 

only

 

soapy

 

water

 

or

 

nonflammable

 

solvent.

 

Summary of Contents for SP3500WS

Page 1: ...1 22 GASOLINE GENERATING SET web www superpowergenerator com E mail verahardworking hotmail com Owner s Manual...

Page 2: ...s as needed 4 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry and long hair can be caught in movi...

Page 3: ...d It will do the job better and more safely at the rate for which it was intended Do not modify this generator and do not use this generator for a purpose for which it was not intended INSTALLATION PR...

Page 4: ...gine Key can be removed inserted ON To run the engine after starting START To start the engine by turning the starter motor 2 The fuel valve is located between the fuel tank and carburetor When the va...

Page 5: ...the starter motor Return the key to the ON position once the engine has started Do not use the starter for more than 5 seconds at a time If the engine fails to start release the switch and wait 10 sec...

Page 6: ...close circuit breaker 2 Turn the engine switch to OFF position 3 Turn the fuel valve lever to the OFF position When the engine is not in use leave the fuel valve lever in the OFF position to prevent c...

Page 7: ...jurisdiction for local codes or ordinances that apply to the intended use of the generator 2 Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a signific...

Page 8: ...sure that the voltmeter indicates the specified voltage Do not exceed the current limit specified for any one receptacle If an overloaded circuit causes the AC circuit breaker to switch OFF reduce the...

Page 9: ...l is a major factor affecting engine performance and service life Non detergent and 2 stroke engine oils will damage the engine and are not recommended Check the oil level BEFORE EACH USE with the gen...

Page 10: ...xtremely flammable and is explosive under certain conditions Refuel in a well ventilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or...

Page 11: ...cable end A battery can explode if you do not follow the correct procedure seriously injuring anyone nearby Keep all sparks open flames and smoking materials away from the battery 1 Connect the batter...

Page 12: ...CE Periodic maintenance and adjustment is necessary to keep the generator in good operating condition Perform the service and inspection at the intervals shown in the maintenance schedule below Exhaus...

Page 13: ...onged periods Although this is unlikely unless you hands used oil on a daily basis it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handing used oil Pl...

Page 14: ...the excess oil The engine will smoke during initial startup if too much oil is left in the air cleaner element 4 Reinstall the air cleaner element and the cover Fuel Sediment Cup Cleaning The sediment...

Page 15: ...er engine operation the spark plug must be properly gapped and free of deposits If the engine has been running the muffler will be very hot Be careful not to touch the muffler 1 Remove the spark plug...

Page 16: ...n improperly tightened spark plug can become very hot and could damage the engine Never use spark plugs which have an improper heat range Use only the recommended spark plugs or equivalent TRANSPORTIN...

Page 17: ...y loosening the drain screw Drain the gasoline into a suitable container Gasoline is extremely flammable and is explosive under certain conditions Perform this task in a well ventilated area with the...

Page 18: ...18 22...

Page 19: ...may ignite 2 Remove the spark plug and install the spark plug in the plug cap YES 3 Set the plug side electrode on the cylinder head 4 Crank the engine sparks should jump across the gap NO To check 1...

Page 20: ...cuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or equipment for any defects Take the generator to an authorized generator dealer Replace the electrical appliance or equi...

Page 21: ...21 22 WIRING DIAGRAM Starting with hand or Electric start...

Page 22: ...22 22 Starting with hand start...

Reviews: