DMX Connection Method

 

 

 

If the lighting working on DMX mode it needs be connected to the DMX controller                                                           

 

For example: if using DMX 8 channels mode, the first DMX address value must be 1st, next device 

should be plugs 8    (e.g., 1,9,17,25...). 

 

Every DMX address can be reused as needed. 

 

DMX address can be any data between 001 and 512. 

 

Note: 1. As this fixture's DMX signal cable connection is Parallel   
                connection, 

please don’t more than 32 units. 

            2. If the signal cable is over 300m between the DMX512 controller   
                And fixture or between two fixtures, then a DMX signal amplifier   
                is needed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Summary of Contents for WKP-3603

Page 1: ...6 3W UV 2018 03 22 This product manual contains important information about the safe installation and use of this product Please read and follow these instruction carefully and keep this manual in a s...

Page 2: ...system Use medicinal absorbent cotton to clean it Please do not attempt to dismantle and or modify the product inner structure Otherwise would not provide 1 year of free warranty Electrical connectio...

Page 3: ...mode static mode and LED display screen Optical System Dimming mode Dimmer 0 fast Linear dimming Dimmer 1 8 soft Non linear dimming Dimmer From 0 100 linear dimming Lens Curved surface efficiency opti...

Page 4: ...onnection Method Please connect power as following L live wire brown wire E earth wire yellow green double color wire N null line blue wire When connecting power ensure that the voltage and frequency...

Page 5: ...1st next device should be plugs 8 e g 1 9 17 25 Every DMX address can be reused as needed DMX address can be any data between 001 and 512 Note 1 As this fixture s DMX signal cable connection is Paral...

Page 6: ...oduction MENU Menu button return button enter the menu selection interface or previous menu ENTER Confirmation button used to confirm the selected function UP DOWN Upward downward select function or P...

Page 7: ...etting was preserved Exit menu static color setting will be removed Note When entered this submenu the light fixture will automatically set to the data status sent by the master other light fixtures s...

Page 8: ...settings parameters 1 DMX 001 2 PERS 1CH 3 7 Temperature control protection State When the temperature of the LED bead plate more than 65 the light fixture begin slowly to reduce the working current...

Page 9: ...ent 160 184 Non linear dimming speed2 DIM 2 Dimmer speed adjustment 185 209 Non linear dimming speed2 DIM 2 Dimmer speed adjustment 210 255 Non linear dimming speed2 DIM 2 Dimmer speed adjustment 5 Ma...

Page 10: ...s damaged or abnormal Call a qualified personnel to fix it Control section is damaged Call a qualified personnel to fix it Connection of internal circuitry is not correct Call a qualified personnel to...

Reviews: