1) HML0 + 00 to HML0 + 3F: Data area

Relationship between “Computer I/O address” and “S-LINK V address”

Computer I/O 
address
(hexadecimal)

S-LINK V

 address

bit 7

bit 6

bit 5

bit 4

bit 3

bit 2

bit 1

bit 0

HML0  +  00

7

6

5

4

3

2

1

0

HML0 + 01

15

14

13

12

11

10

9

8

HML0 + 02

23

22

21

20

19

18

17

16

HML0 + 03

31

30

29

28

27

26

25

24

HML0 + 04

39

38

37

36

35

34

33

32

HML0 + 05

47

46

45

44

43

42

41

40

HML0 + 06

55

54

53

52

51

50

49

48

HML0 + 07

63

62

61

60

59

58

57

56

HML0 + 08

71

70

69

68

67

66

65

64

HML0 + 09

79

78

77

76

75

74

73

72

HML0 + 0A

87

86

85

84

83

82

81

80

HML0 + 0B

95

94

93

92

91

90

89

88

HML0 + 0C

103

102

101

100

99

98

97

96

HML0 + 0D

111

110

109

108

107

106

105

104

HML0  +  0E

119

118

117

116

115

114

113

112

HML0 + 0F

127

126

125

124

123

122

121

120

HML0 + 10

135

134

133

132

131

130

129

128

HML0 + 11

143

142

141

140

139

138

137

136

HML0 + 12

151

150

149

148

147

146

145

144

HML0 + 13

159

158

157

156

155

154

153

152

HML0 + 14

167

166

165

164

163

162

161

160

HML0 + 15

175

174

173

172

171

170

169

168

HML0 + 16

183

182

181

180

179

178

177

176

HML0 + 17

191

190

189

188

187

186

185

184

HML0 + 18

199

198

197

196

195

194

193

192

HML0 + 19

207

206

205

204

203

202

201

200

HML0 + 1A

215

214

213

212

211

210

209

208

HML0 + 1B

223

222

221

220

219

218

217

216

HML0 + 1C

231

230

229

228

227

226

225

224

HML0 + 1D

239

238

237

236

235

234

233

232

HML0 + 1E

247

246

245

244

243

242

241

240

HML0 + 1F

255

254

253

252

251

250

249

248

HML0 + 20

263

262

261

260

259

258

257

256

HML0 + 21

271

270

269

268

267

266

265

264

HML0 + 22

279

278

277

276

275

274

273

272

HML0 + 23

287

286

285

284

283

282

281

280

HML0 + 24

295

294

293

292

291

290

289

288

HML0 + 25

303

302

301

300

299

298

297

296

HML0 + 26

311

310

309

308

307

306

305

304

HML0 + 27

319

318

317

316

315

314

313

312

HML0 + 28

327

326

325

324

323

322

321

320

HML0 + 29

335

334

333

332

331

330

329

328

HML0 + 2A

343

342

341

340

339

338

337

336

HML0 + 2B

351

350

349

348

347

346

345

344

HML0 + 2C

359

358

357

356

355

354

353

352

HML0 + 2D

367

366

365

364

363

362

361

360

HML0 + 2E

375

374

373

372

371

370

369

368

HML0 + 2F

383

382

381

380

379

378

377

376

HML0 + 30

391

390

389

388

387

386

385

384

HML0 + 31

399

398

397

396

395

394

393

392

HML0 + 32

407

406

405

404

403

402

401

400

HML0 + 33

415

414

413

412

411

410

409

408

HML0 + 34

423

422

421

420

419

418

417

416

HML0 + 35

431

430

429

428

427

426

425

424

HML0 + 36

439

438

437

436

435

434

433

432

HML0 + 37

447

446

445

444

443

442

441

440

HML0 + 38

455

454

453

452

451

450

449

448

Summary of Contents for SL-VISA

Page 1: ...CMJE SLVISA No 0006 81V...

Page 2: ...cable Take care that wrong wiring will damage the product Wiring This product has been developed produced for industrial use only In case noise generating equipment switching regulator inverter motor...

Page 3: ...d Tightening torque of the terminal screws 0 5 to 0 6 N m Terminal block connector MSTB2 5 7 STF 5 08 with ange Made by Phoenix Contact 2 I O rst address setting switch SW5 SW6 I O rst address setting...

Page 4: ...rol number is set with the I O control number setting switch SW2 5 to SW2 8 Setting is read in only once when power is supplied to the computer Changing the mode switch setting during operation is ine...

Page 5: ...d and the connection condition including the addresses where Error 4 has occurred is read again and stored 6 Transmission indicator Green It blinks when communicating during signal transmission with t...

Page 6: ...or No clear indication Default indication System set indication Interruption indication Busy indication On hold indication Under com mand execution indication Control board Computer R HML0 4B Bank cha...

Page 7: ...2 HML0 19 207 206 205 204 203 202 201 200 HML0 1A 215 214 213 212 211 210 209 208 HML0 1B 223 222 221 220 219 218 217 216 HML0 1C 231 230 229 228 227 226 225 224 HML0 1D 239 238 237 236 235 234 233 23...

Page 8: ...ffected S LINK V I O unit is indicated When each bit is 1 the S LINK V I O unit having the allocated address has a cable break or the I O unit is in abnormal condition In case Bank change over respons...

Page 9: ...uit switches to the bank change over response register and then writes in the bank number User s computer It reads out bank number of the bank change over response register User s computer When the re...

Page 10: ...When setting is done by a program I Os can be set in units of 16 In this case set all the I O set ting switches to input 0 ON If the change is done by software it is automatically changed within 1 to...

Page 11: ...t be transmitted After the output data is written if 1 is written into HML0 49 bit 0 and the next output data is written in after con rming that HML0 4A bit 0 has turned to 1 then output data transmis...

Page 12: ...nding to HML0 49 once and check that the bit corresponding to HML0 4A has turns to 0 prior to the execution 2 System set and Command cannot be executed during an interruption occurrence Only clear anc...

Page 13: ...or 0 OFF ON when bit 1 is 1 bit 7 6 5 4 3 2 1 0 Assignment Input hold 1 Hold 0 Hold cancel Input change interruption 1 Effective 0 Ineffective Occurrence condition for input change interruption 1 ON O...

Page 14: ...tsushita Electronic Compo nents Co Ltd 3 Use a local power supply at a cable distance of less than 10m from each I O device Conditions in use for CE conformity Note Do not connect a surge absorber bet...

Page 15: ...and 1 s pulse width Common 1 000Vp 10ms cycle 1 s pulse width with noise simulator Voltage withstandability Note 5 1 000V AC for one min between external terminals and ground Insulation resistance Not...

Page 16: ...the delivery of the product 3 Failure caused by a development which could not be foreseen based upon the technology in practice at the time of purchase or contract 4 Failure caused by use which deviat...

Reviews: