background image

PRESSURE SENSORS

DP5/DPH

Head-separated

DP4

DP2

DP3

DP-M

Digital Display

PE

LED Bar Display

DP4

781

APPLICATIONS

Checking IC absorption

Checking degree of vacuum for vacuum molding

Checking reference pressure of device

DP4-50

DP4-50

DP4-52

Can be mounted on a DIN rail

Change-over to analog bar display possible

The sensor can be mounted even on a 35 mm 

1.378 in

width DIN rail by using the

optional DIN rail mounting bracket (MS-DP-2).
It can be mounted in a narrow space inside of your device.

The pressure changes can be
indicated as a bar display. The analog
bar color reflects the changes in the
output. (The detected pressure value
is displayed in steps of 14 % F.S.
approx.)

Flexible control with four output modes

100 kPa compound pressure type available

To serve a broad range of pressure
needs, we offer 

100.0 kPa, compound

pressure type, in addition to the 0 to
101.3 kPa and 0 to 1.000 MPa types.

Incorporated with the memory bank function

You can store two patterns of set
values. Hence, the setup can be
changed by a single touch.

Selection from six pressure units

The pressure unit can be selected from six
different systems to suit your requirement.

The selectable pressure units differ
with the sensor type. When the
pressure unit is changed, the
measured pressure value and the set
values are automatically converted.

MS-DP-2

High speed response of 2 ms or less

The sensor has a high speed response of 2 ms
or less.
In addition, the sensor has a chattering
prevention function. This allows change-over
of the response time so that fluctuation of the
reference pressure generated during operation
of the large-diameter cylinder and the ejector is
not detected as an abnormal pressure.

0

Pressure

Set value

Output

Output

Time

2 ms

16 ms

128 ms

512 ms

4 steps

change-over

Response time

At 2 ms

At 128 ms

Mountable from four 
different directions

ON

OFF

Output

Hysteresis

Set Value 1

 (P-1)

Set Value 2

 (P-2)

Low pressure

High pressure

ON

OFF

Output

Hysteresis Hysteresis

Set Value 1

 (P-1)

Set Value 2

 (P-2)

Low pressure

High pressure

MODE

MODE

UP UP

UP

Sensing

mode

Sensing

mode

Forced 

output 

mode

ON

OFF

Output

Press 

      key

Press 

      key

ON

OFF

Output

Hysteresis

Set Value 1 (P-1)

Set Value 3 (P-3)

Set Value 2 (P-2)

Low pressure

High pressure

0 to 

101.3 kPa

0 to 1.000 MPa

100.0 to 100.0 kPa

0

Output
OFF

Output
ON

DP4-50(P)

Vacuum pressure type

DP4-52(P)

Positive pressure type

DP4-57(P)

Compound pressure type

Hysteresis mode

The hysteresis of the output can
be set, as desired, with the set
values.

Window comparator mode

The output can be turned ON or
OFF by a pressure within the set
range.

Automatic sensitivity setting mode

Using actual objects, if the pressure
values for OK objects and NG
objects are input, then the sensor
automatically set to the optimum
pressure value (mid-value).

Forced output mode

The output is forcibly maintained
in the OFF state in the sensing
mode, irrespective of the set
values.

1

2

3

4

Note: The above figure is for the case when the

output operation is set to NO (normally open).

Note: The above figure is for the case when the

output operation is set to NO (normally open).

Note: The above figure is for the case when the

output operation is set to NO (normally open).

Note: The above figure is for the case when the

output operation is set to NO (normally open).

inHg

kPa

mmHg

psi

bar

(Note)

kgf/cm

2

: Positive pressure type

: Vacuum pressure type

International System of Units (SI)

Note: ‘MPa’ in case of DP4-52(P) positive pressure type

Analog bar display

Digital display

Summary of Contents for DP4 Series

Page 1: ...mm 60 mm 2 362 in 60 mm 2 362 in Snap fit connector is used for cable connection The cable has a snap fit connector for easy mounting and removal The connector can be easily assembled by yourself Fur...

Page 2: ...nd the ejector is not detected as an abnormal pressure 0 Pressure Set value Output Output Time 2 ms 16 ms 128 ms 512 ms 4 steps change over Response time At 2 ms At 128 ms Mountable from four differen...

Page 3: ...3 C5 DIN rail mounting bracket MS DP 2 Sensor mounting bracket MS DP 3 MS DP 4 Label space MS DP 5 Panel fixing screw Accessory Horizontal multiple panel mounting bracket MS DP 5 m The above illustrat...

Page 4: ...ent temperature range 0 to 50 C 32 to 122 F within 5 F S of detected pressure at 25 C 77 F M5 female thread Front case ABS LCD display PET Rear case PBT M5 threaded part Brass nickel plated Connector...

Page 5: ...agram Pin position Symbols D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr PNP output transistor 1 3 2 ZD D 100 mA max Tr Terminal No Color code of connector attached cab...

Page 6: ...series is a CE conformity product complying with EMC Directive The harmonized standard with regard to immunity that applies to this product is EN 61000 6 2 Note and the following condition must be me...

Page 7: ...each time the key is pressed MODE MODE If key protect has been set make sure to release key protect before operating the keys Please refer to Key protect function on p 787 for the procedure Set Value...

Page 8: ...than forced output mode the mode will change to pressure value setting mode After releasing the mode select key press the key again continuously until is displayed 4 sec or more Make the setting for S...

Page 9: ...Further tighten both the right and the left screw gradually and equally so that the panel mounting bracket does not tilt 13 mm 0 512 in spanner M3 length 15 mm 0 591 in panel fixing screw Accessory Pa...

Page 10: ...2 362 37 1 457 17 0 669 0 5 0 0 020 0 0 5 0 0 020 0 37 1 457 0 5 0 0 020 0 X 0 5 0 0 020 0 X when n unit is installed X 20 n 1 17 mm 0 669 in Note The panel thickness should be 1 to 6 mm 0 039 to 0 23...

Page 11: ...559 Material Cold rolled carbon steel SPCC nickel plated Note Use with the panel mounting bracket MS DP 1 included with the sensor Material Cold rolled carbon steel SPCC nickel plated Note Use with th...

Page 12: ...ke sure that the tightening torque is 1N m or less If excessive tightening torque is applied the commercial fitting may break b I O CIRCUIT DIAGRAM Pin position Pin position NPN output type Horizontal...