background image

12 to 24V DC

%

+

10

15

+

Terminal No.

(Black)
Comparative output

Internal circuit

Users’ circuit

100mA max.

D

Tr

Z

D

(Blue) 0V

Comparative
output

2

(Brown) 

+

V

Load

Sensor circuit

1

2

3

1

0V

3

+

V

Color code of connector attached cable

12 to 24V DC

%

+

10

15

+

Internal circuit

Users’ circuit

100mA max.

D

Tr

Z

D

Comparative
output

2

Load

Sensor circuit

3

2

1

1

3

0V

+

V

Terminal No.

(Black)
Comparative output

(Blue) 0V

(Brown) 

+

V

Color code of connector attached cable

Thank you very much for using SUNX sensors. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this
sensor. Kindly keep this manual in a convenient place for quick reference.

INSTRUCTION MANUAL

Compact Size·Digital Pressure Sensor

DP4 Series

x

CAUTIONS

DP4 series is designed for use with non-corrosive gas. It cannot be used
for liquid or corrosive gas.

Use within the rated pressure range.

Do not apply pressure exceeding the pressure withstandability value. The
diaphragm will get damaged and correct operation shall not be maintained.

Make sure to carry out the wiring in the power supply off condition.

Take care that wrong wiring will damage the sensor.

Verify that the supply voltage variation is within the rating.

If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
ground.

In case noise generating equipment (switching regulator, inverter motor, etc.)
is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal
of the equipment to an actual ground.

Do not use during the initial transient time (3 sec. approx.) after the power
supply is switched on.

Make sure that stress is not applied directly to the connector cable joint.

If the used power supply generates a surge, connect a surge absorber to the
power supply to absorb the surge.

Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.

In order to reduce noise, make the wiring as short as possible.

Avoid dust, dirt, and steam.

Take care that the sensor does not come in direct contact with water, oil,
grease, or organic solvents, such as, thinner, etc.

Do not insert wires, etc., into the pressure port. The diaphragm will get dam-
aged and correct operation shall not be maintained.

Do not operate the keys with pointed or sharp objects.

v

MOUNTING

Mount the enclosed panel mounting bracket (MS-DP-1) as shown in the fig-
ure below.
The tightening torque should be 0.15N·m or less. Further, tighten both the
right and the left screw gradually and equally, so that the panel mounting
bracket does not tilt.
Sensor mounting bracket (MS-DP-3) which can be mounted on a horizontal
plane and sensor mounting bracket (MS-DP-4) which can be mounted on a
vertical plane are also available.

c

PIPING

When connecting a commercial M5 coupling to
the pressure port, hold the flat sides of the pres-
sure port with a 13mm spanner and make sure
that the tightening torque is 1N·m or less.
If excessive tightening torque is applied, the
commercial fitting may break.

b

I/O CIRCUIT DIAGRAM

• Pin position

• Pin position

NPN output type

Horizontal mounting

Vertical mounting

PNP output type

Panel cut-out dimensions

(Unit: mm)

(Thickness = 1 to 6mm)

M3 (length 15mm)
pan head screw
(Accessory)

Panel mounting bracket
(MS-DP-1) (Accessory)

37

+0.5
  0

+0.5
  0

17

DIN rail mounting bracket
(MS-DP-2) (Optional)

35mm width DIN rail

13mm spanner

z

SPECIFICATIONS

Symbols ... D : Reverse supply polarity protection diode

Z

D

: Surge absorption zener diode

T

r

: NPN output transistor

Symbols ... D : Reverse supply polarity protection diode

Z

D

: Surge absorption zener diode

T

r

: PNP output transistor

For use outside Japan

MJE-DP4 No.6035-02

This product is not a safety sensor. Its use is not intended or designed
to protect life and prevent body injury or property damage from dan-
gerous parts of machinery. It is a normal pressure detection sensor.

In case this sensor is used within Japan, SI unit must be used since
use of pressure units in Japan is restricted to SI units.

DIN rail mounting bracket (MS-DP-2), which can fit on a 35mm width DIN rail,
is also available.

Vacuum pressure

Positive pressure

Compound pressure

–101kPa type

1MPa type

±

100kPa type

DP4-50

DP4-52

DP4-57

DP4-50P

DP4-52P

DP4-57P

Gauge pressure

0 to –101.3kPa

0 to 1.000MPa

–100.0 to 100.0kPa

5.1 to –101.3kPa

–0.050 to 1.050MPa

–101.3 to 105.0kPa

490kPa

1,470kPa

490kPa

Non-corrosive gas

1 digit (however, variable in hysteresis mode and 2 digits when using psi unit)

12 to 24V DC

+

1
1

0
5

 %

Ripple P-P 10% or less

40mA or less

<

NPN output type

>

<

PNP output type

>

NPN open-collector transistor

PNP open-collector transistor

• Maximum sink current: 100mA

• Maximum source current: 100mA

• Applied voltage: 30V DC or less

• Applied voltage: Same as supply voltage

(between comparative output and 0V)

(between comparative output and 

+

V)

• Residual voltage: 1V or less

• Residual voltage: 2V or less

(at 100mA sink current)

(at 100mA source current)

0.4V or less

(at 16mA sink current)

Type

Model

NPN output

Item

No.

PNP output

Type of pressure

Rated pressure range

Set pressure range

Pressure withstandability

Applicable fluid

Hysteresis

Supply voltage

Current consumption

NO/NC (selectable by key operation)

Within 

±

0.2% F.S. 

±

1 digit

Within 

±

0.2% F.S. 

±

2 digits

(within 

±

3 digits)

(within 

±

6 digits)

2ms, 16ms, 128ms, 512ms or less (selectable by key operation)

3

1

/

2

 digit LCD display (with red and green backlight)

0 to 

+

50˚C (No dew condensation), Storage: –10 to 

+

60˚C

35 to 85% RH, Storage: 35 to 85% RH

Over ambient temperature range 

+

10 to 

+

40˚C: within 

±

2% F.S. of detected pressure at 

+

25˚C

Over ambient temperature range 0 to 

+

50˚C: within 

±

5% F.S. of detected pressure at 

+

25˚C

M5 female thread

Front case: ABS, LCD display: PET

Rear case: PBT [M5 screw part: brass (nickel plated)]

30g approx.

Panel mounting bracket (MS-DP-1): 1 set, Pressure unit label: 1 No.

Connector: 1 set (Housing: 1 No., Connector pin: 3 Nos.)

Output operation

Repeatability

Response time

Display

Ambient temperature

Ambient humidity

Temperature characteristics

Pressure port

Material

Weight

Accessories

Comparative output

Ramco Innovations                                          (800) 280-6933                                   www.sunxsensors.com

Summary of Contents for DP4 Series

Page 1: ...mm 60 mm 2 362 in 60 mm 2 362 in Snap fit connector is used for cable connection The cable has a snap fit connector for easy mounting and removal The connector can be easily assembled by yourself Fur...

Page 2: ...nd the ejector is not detected as an abnormal pressure 0 Pressure Set value Output Output Time 2 ms 16 ms 128 ms 512 ms 4 steps change over Response time At 2 ms At 128 ms Mountable from four differen...

Page 3: ...3 C5 DIN rail mounting bracket MS DP 2 Sensor mounting bracket MS DP 3 MS DP 4 Label space MS DP 5 Panel fixing screw Accessory Horizontal multiple panel mounting bracket MS DP 5 m The above illustrat...

Page 4: ...ent temperature range 0 to 50 C 32 to 122 F within 5 F S of detected pressure at 25 C 77 F M5 female thread Front case ABS LCD display PET Rear case PBT M5 threaded part Brass nickel plated Connector...

Page 5: ...agram Pin position Symbols D Reverse supply polarity protection diode ZD Surge absorption zener diode Tr PNP output transistor 1 3 2 ZD D 100 mA max Tr Terminal No Color code of connector attached cab...

Page 6: ...series is a CE conformity product complying with EMC Directive The harmonized standard with regard to immunity that applies to this product is EN 61000 6 2 Note and the following condition must be me...

Page 7: ...each time the key is pressed MODE MODE If key protect has been set make sure to release key protect before operating the keys Please refer to Key protect function on p 787 for the procedure Set Value...

Page 8: ...than forced output mode the mode will change to pressure value setting mode After releasing the mode select key press the key again continuously until is displayed 4 sec or more Make the setting for S...

Page 9: ...Further tighten both the right and the left screw gradually and equally so that the panel mounting bracket does not tilt 13 mm 0 512 in spanner M3 length 15 mm 0 591 in panel fixing screw Accessory Pa...

Page 10: ...2 362 37 1 457 17 0 669 0 5 0 0 020 0 0 5 0 0 020 0 37 1 457 0 5 0 0 020 0 X 0 5 0 0 020 0 X when n unit is installed X 20 n 1 17 mm 0 669 in Note The panel thickness should be 1 to 6 mm 0 039 to 0 23...

Page 11: ...559 Material Cold rolled carbon steel SPCC nickel plated Note Use with the panel mounting bracket MS DP 1 included with the sensor Material Cold rolled carbon steel SPCC nickel plated Note Use with th...

Page 12: ...ke sure that the tightening torque is 1N m or less If excessive tightening torque is applied the commercial fitting may break b I O CIRCUIT DIAGRAM Pin position Pin position NPN output type Horizontal...

Page 13: ...types Positive pressure and compound pressure types Corrective action Switch off the power supply and check the load Applied pressure at the pressure port should be brought to atmos pheric pressure a...

Page 14: ...g mode Zero point adjustment Sensing mode UP key DOWN key Release the keys Setting procedure Sensing mode Initial setting mode Setting item selection UP key MODE key UP key Setting condition selection...

Page 15: ...ctively i Press MODE key to enter Set Value 3 or Set Value 6 o Sensor returns to the sensing mode and setting is com pleted Setting procedure Sensing mode MODE key MODE key MODE key Sensing mode MODE...

Reviews: