Sunx DP-100-M Series Instruction Manual Download Page 3

MENU SETTING MODE

9

٨

٨

٨

When the mode selection key is held down for two seconds in the RUN
mode, the menu setting mode will open.
The mode will change to the RUN mode when the mode selection key is
held down during this setting process.
The leftmost setting items are the default settings (factory settings).

Setting item

Description

Comparative output 1
output mode setting

Sets the output operation of comparative output 1.

Comparative output 2
output mode setting
(Standard type only)

Sets the output operation of comparative output 2.

Pressure unit can be changed.

Response time setting

Sets the response time.
The response time can be selected from 2.5ms, 5ms, 10ms, 25ms, 50ms,
100ms, 250ms, 500ms, 1,000ms or 5,000ms.

Displayed color of the
main display selection

Displayed color of the main indicator can be changed.

Unit selection

N.O. / N.C. selection

Normal open (N.O.) or normal close (N.C.) can be selected.

Analog voltage output /
external input selection
(High-function type only)

Selects analog voltage output, auto-reference input, or remote zero-ad-
justment input.

Notes: 1)

2)
3)
4)

If the comparative output 2 output mode setting is set to '

', the display of

N.O. / N.C. selection is the same as the high-function type.
The default setting of the high pressure type is '

', and that of the low pressure type is '

'.

The default setting of the low pressure type is '

'. '

' is not displayed.

This is not displayed on the high-pressure type.

Standard type

High-function type

(OFF mode)

<RUN mode>

<Comparative output 1 output mode setting>

<Analog voltage output / external input selection>

<Comparative output 2 output mode setting> (Note 1)

(EASY mode)

(2.5ms)

(5ms)

(5,000ms)

MODE

MODE

MODE

(N.O.)

(N.C.)

<N.O. / N.C. selection> (Note 2)

MODE

MODE

࡮࡮࡮࡮࡮

MODE

<RUN mode>

MPa

(Note 3)

(kPa)

(bar)

(mmHg) (Note 4)

(inchHg) (Note 4)

(psi)

(kgf/cm

2

)

<Response time setting>

<Display color of the main display selection>

Hysteresis
mode

Window
comparator
mode

Analog
voltage
output

Remote
zero-adjust-
ment input

(EASY mode)

Hysteresis
mode

<N.O. / N.C. selection> (Note 1) (Note 2)

Output 1: N.O.
Output 2: N.O.

Output 1: N.C.
Output 2: N.O.

Output 1: N.O.
Output 2: N.C.

Output 1: N.C.
Output 2: N.C.

Window
comparator
mode

Standard type

High-function type

Press for 2 sec.

MODE

Red when ON
Green when OFF

Red when ON
Green when OFF

(Always red)

(Always green)

Auto-refer-
ence input

High-function type

Common

<Setting condition 7>

Comparative output 1 output mode: '

' (EASY mode)

Analog voltage output / external input selection: '

' (Analog voltage output)

<RUN mode state>

Note: Auto-reference value and remote zero-adjustment value are displayed.

For details, refer to '

AUTO-REFERENCE FUNCTION

' and '

REMOTE

ZERO-ADJUSTMENT FUNCTION

'.

12

13

<Setting condition 9>

Comparative output 1 output mode: '

' (Hysteresis mode) or

'

' (Window comparator mode)

Analog voltage output / external input selection: '

' (Analog voltage output)

<RUN mode state>

Automatic

Automatic

MODE

<Setting condition 8>

Comparative output 1 output mode: '

' (EASY mode)

Analog voltage output / external input selection: '

' (Auto-reference input) or

'

' (Remote zero-adjustment input)

<RUN mode state>

(Note)

Automatic

MODE

Blinks alternately

٨

The key lock function prevents key operations so that the conditions set
in each setting mode are not inadvertently changed.

Key lock function

<Key lock set>

<Key lock released>

Hold
down

MODE

(Key lock released)

Automatic

Hold
down

(Key lock set)

Automatic

MODE

<Setting condition 10>

Comparative output 1 output mode: '

' (Hysteresis mode) or

'

' (Window comparator mode)

Analog voltage output / external input selection: '

' (Auto-reference input) or

'

' (Remote zero-adjustment input)

<RUN mode state>

(Note)

Automatic

Automatic

MODE

MODE

MODE

Blinks alternately

٨

The zero-adjustment function forcibly sets the pressure value to 'zero'
when the pressure port is opened.

Zero-adjustment function

Hold
down

Automatic

<Peak / bottom hold set>

<Peak / bottom hold released>

٨

٨

The peak / bottom hold functions display the peak value and bottom val-
ue of the fluctuating pressure.
The peak value is displayed on the main display and the bottom value is
displayed on the sub-display

.

Peak / bottom hold function