Sunx DP-100-M Series Instruction Manual Download Page 1

Thank you very much for using SUNX products. Please read this
Instruction Manual carefully and thoroughly for the correct and optimum
use of this product. Kindly keep this manual in a convenient place for quick
reference.

WARNING

٨
٨

٨

٨

Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products
which meet laws and standards, such as OSHA, ANSI or IEC etc., for
personnel protection applicable in each region or country.

DP-100

series is designed for use with non-corrosive gas. It cannot be

used for liquid or corrosive gas.
Japanese Measurement Laws prohibit the use of this product in Japan.

NAMES OF EACH PART

1

INSTRUCTION MANUAL

High-performance Digital Display

Pressure Sensor

MJE-DP100 No.0004-94V

DP-100

Series

For use outside Japan

Standard type

High-function type

PNP output type

Standard type

NPN output type

When using the analog voltage output, take care to the input impedance of
the connected device.
Furthermore, note that if the cable is extended, the cable resistance will
cause the voltage to drop.

I/O CIRCUIT DIAGRAMS

5

High-function type

Main

circuit

(Black) Comparative output 1

Users' circuit

Internal circuit

+

_

12 to 24V DC
±10%

(Blue) 0V

(White)
Analog voltage output
or external input

1k

ǡ

100mA max.

Load

Users' circuit

Internal circuit

+
_

12 to 24V DC
±10%

(Black)
Comparative output 1

Main

circuit

(White) Comparative output 2

(Blue) 0V

100mA max.

100mA max.

Load

Load

(Brown) +V

Color code of cable with connector

Main

circuit

Users' circuit

Internal circuit

+
_

12 to 24V DC
±10%

(White)
Analog voltage output
or external input

(Black) Comparative output 1

(Blue) 0V

100mA max.

5V

1k

ǡ

Load

(Brown) +V

Color code of cable with connector

Main

circuit

Users' circuit

Internal circuit

+

_

12 to 24V DC
±10%

(Black) Comparative output 1

(White) Comparative output 2
(Blue) 0V

100mA max.

100mA max.

Load

Load

(Brown) +V

Color code of cable with connector

(Brown) +V

Color code of cable with connector

Note: Do not pull by holding the cable without pressing the release lever, as this can

cause cable break or connector break.

Ԙ

ԙ

Ԛ

ԛ

<Connection connector pin arrangement>

Connector pin No.

Terminal name

+V

Ԙ

Comparative output 1

ԙ

Standard type: Comparative output 2
High-function type: Analog voltage output or external input

Ԛ

0V

ԛ

Connection method

Disconnection method

٨

Insert the cable with connector

CN-14A-C

غ

into this product's connection connector
section as shown in the right figure.

٨

Pressing the release lever of the cable
with connector, pull out the connector.

WIRING

4

<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]

Cable with connector

CN-14A-C

غ

Release lever

٨

When connecting a commercial coupler to the pressure port, attach a
12mm spanner (14mm for

DP-100-E

type) to the pressure port's hexagon

section to fix the port, and then tighten with a tightening torque of 9.8N

m

or less (M5 female: 1N

m or less). The commercial coupler or pressure

port section will be damaged if the tightening torque is excessive.
Wrap sealing tape around the coupler when connecting to prevent leaks.

PIPING

2

12mm spanner

MOUNTING

3

٨

The sensor mounting bracket (

MS-DP1-1

) is available as an option.

When mounting the sensor onto the sensor mounting bracket, etc., the
tightening torque should be 0.5N

m or less.

٨

٨

٨

The panel mounting bracket

MS-DP1-2

(optional) and

MS-DP1-4

(op-

tional), as well as the front cover

MS-DP1-3

(optional) and

DPX-04

(op-

tional) are also available.
The type of the front cover is different depending on the applied mount-
ing bracket. Use

MS-DP1-3

for

MS-DP1-2

, and

DPX-04

for

MS-DP1-4

.

For mounting of the panel mounting bracket, refer to the Instruction
Manual enclosed with

MS-DP1-2

or

MS-DP1-4

.

Sensor mounting bracket

MS-DP1-1

(Optional)

M3 (length 6mm) screws
with washers

(Accessory with

MS-DP1-1

)

Connection
connector

DP-100

type: R

1

8

+ M5 female screw

DP-100-E

type: G

1

8

+ M5 female screw

DP-100-M

type: M5 female screw

DP-100-N

type: NPT

1

8

+ M5 female screw

Pressure port

DP-100

Setting value
DOWN key

Setting value UP key

Standard type:

Lights up when compa-
rative output 2 is ON

High-function type:

Lights up when analog
voltage output is set

Output 2 / analog
voltage output oper-
ation indicator

Lights up when compa-
rative output 1 is ON

Output 1 operation
indicator

Mode selection key

Main display

Unit display
(Note)

Sub display

Note: If set the pressure unit other than 'MPa' or 'kPa', attach the unit switching label

corresponds to the set pressure unit.

Reviews: