5  Electrical connection

 

Danger of death through electric shock!

Touching live parts can result in death.

Make sure the polarity is correct when connecting 
the modules. Reverse polarity can lead to destruction 
of the protective diodes.

Before installing check junction box, the cables and 
connectors for obvious damage.

For safety reasons the junction box must not be 
opened.

Do not use the plug connectors if the plug contacts 
are dirty!

Do not install damaged solar modules!

The solar modules, and in particular the connectors 
and tools, must be dry during installation.

In exposed locations, installation of lightning protec-
tion is recommended. If lightning protection equip-
ment is already present, the solar modules must be 
integrated properly. Follow the respective current 
regulations.

During normal conditions PV module may supply a 
higher current and/or voltage than specified under 
test conditions.

For determining the voltage design values of the 
components, the current design values of the con-
ductors, the ratings of the fuses and the control units 
connected to the solar module output, the values of 
I

SC

 and U

OC

 specified on the module should be multi-

plied with a factor of 1.25.

The solar module is equipped with high-quality solar 
cables and the Tyco plug connector system, which 
is protected against reverse polarity and accidental 
contact. The connection polarity is marked. 

The minimum cable cross-section should be 4 mm

2

.

5.1  Tyco Solarlok plug connector system

The Solarlok plug connector system is designed for 
convenient, reliable connection of individual solar 
generators and the Solar Inverter. 

Plug connections 
The positive/negative coded connectors are marked 
with polarity symbols and a coloured ring (blue = 
negative, red = positive. They are equipped with 
coding ribs for assignment, which ensure that only 
connectors of the same polarity can be connected to 
each other.

Connecting socket and plug:
The system is only correctly locked if the locking 
hooks are recessed flush in the mating piece.

 

CAUTION

The plug connectors must not be disconnected or 
connected under load current! They may be con-
nected and disconnected while voltage is present. 

Release the locking mechanism by pressing on the 
ribbing of the locking hooks and pulling the connec-
tors apart.

5.2  Application class

Sunways Solar Modules conform to application class 
A according to the international safety standard 
EN 61730 and therefore meet the requirements of 
protection class II. 

Sunways Solar Modules can be used in systems with a 
DC voltage in excess of 120 V

DC

.

5.3  Earthing of the modules

An overview of the solar module can be found in sec-
tion 2, Your Solar Modules. A diagram indicates the 
holes for connecting the earthing cables.

Detail view of the earthing cable connection

3

4

5

2

6

7

1

1  Fastening screw M6
2  Ring terminal with earthing cable
3  Hole for earthing
4  Lock washer
5  Module frame
6  Spring washer
7  Nut

Proceed as follows to ensure correct earthing of the 
modules:

1. 

Place the lock washer (4) and the ring terminal 
with the earthing cable (2) over the earthing hole 
(3) on the front of the module. 

2. 

Insert the fastening screw M6 (1). 

3. 

Then push the spring washer (6) from the under-
side of the module onto the fastening screw (1) 
and fasten the nut (7).

6  Care and maintenance

Check your solar generator approx. every three years 
for soiling. This occurs especially on the lower edge 
of the modules and forms a haze that cannot be 
washed off even by heavy rain.

In the event of significant dirt build-up we recom-
mend cleaning the glass surface. Use plenty of 
lukewarm water and a soft brush. This prevents loss 
of yield.

 

CAUTION

Do not use strong cleaning agents and metallic 
objects, in order to avoid damage to the hardened 
glass surface!

Occasionally check the cables for damage, corrosion 
and make sure they are secure.

Summary of Contents for SM 230M

Page 1: ... the full open circuit voltage can be expected in the modules During all installation and wiring work the modules must therefore be covered or disconnected from the consumer load Otherwise there is a risk of arc formation on lines carrying direct current Suitable fall protection must be used when working on roof mounted solar generators The standard solar module is a glass film product and must no...

Page 2: ...r points drill holes in the long sides see dia gram in section 2 Your Solar Modules The frame is structurally approved for mounting on the long sides Mounting on the short module sides must be avoided The maximum tolerance is 100 mm 100 100 100 100 1000 Insertion systems U shaped profile over the whole long short side are permitted under the following load conditions Short side mounting Mounting r...

Page 3: ...sure that only connectors of the same polarity can be connected to each other Connecting socket and plug The system is only correctly locked if the locking hooks are recessed flush in the mating piece CAUTION The plug connectors must not be disconnected or connected under load current They may be con nected and disconnected while voltage is present Release the locking mechanism by pressing on the ...

Page 4: ...ny declares under its sole responsibility that the solar module types listed above meet the requirements of the following standards DIN EN 50178 EN 50081 1 2 EN 50082 1 2 DIN VDE 0101 DIN VDE 0110 and therefore comply with the EC Directives listed above Roland Burkhardt CTO Sunways AG Photovoltaic Technology Macairestraße 3 5 78467 Konstanz Germany Phone 49 0 7531 996 77 0 Fax 49 0 7531 996 77 444...

Reviews: