Pre-Installation Planning
Before you begin to assemble your sunbed, you should observe the following pre-
installation considerations.
Installation-Pre-Installation Planning
• Your sunbed operates from a 220V ac source. You should have an
electrical outlet (like the type shown below) installed in the room in
which you will use the unit. The outlet should be on a dedicated circuit.
(We recommend installation by a professional electrician.) The outlet
must be earth grounded.
20 AMP NEMA #6-20R RECEPTACLE
30 AMP NEMA #L6-30R RECEPTACLE
REQUIRED FOR 24S SERIES
REQUIRED FOR 28LX SERIES
• Make sure the room in which you intend to use your sunbed is well
ventilated. Air from the room is used to cool the sunbed, and a poorly
ventilated room may cause the unit to become hot and cause discomfort
to the user.
• Your sunbed is designed to operate in an ambient room temperature of
80°F maximum and 70% relative humidity.
• Place your sunbed no closer than 6" from any wall. Make sure that cur-
tains, drapes, and other room furniture do not obstruct the airflow into
the end caps or out of the fan opening areas.
• Proper assembly of your sunbed requires three people. Plan to have a
couple of helpers assist you.
IMPORTANT!
Use of a voltage
source above 230
VAC may prevent
proper operation
of the sunbed
and could cause
damage and void
the warranty.