background image

 

- 4 - 

 
Hints and Tips 
 

1.  Receiver RED LED ‘steady on’ 

This could be an indication of dead batteries, or some temporary interference with the radio signal. 
 
 

2.  Commissioning 

If nothing has happened after 20 seconds of holding the INSTALL button pressed, check the TLX 7506 thermostat is still 
transmitting (i.e. it may have been more than 5 minutes since it was started) 

         

3.  Minimum set point  

If while adjusting the Set Point it is found that it cannot be set below 16°C, check with the installer that the unit has not been 
configured to restrict the minimum Set Point. (This is often required for installations in sheltered accommodation). See 
‘CONFIGURING’ above for details of how to re-configure the unit. 

 

4.  Failure to operate 

If the heating fails to come on when the thermostat is calling for heat, check the ‘Battery Low’ indicator on the thermostat 
display. If the display has faded, replace the batteries as you may have previously overlooked the battery low indications. If 
the batteries are removed for more than 5 – 10 minutes, the unit may need to be re-commissioned. (See above). 

 

 

OPERATION 

 
The TLX 7506 Digital room thermostat is simple to use. The  large 12MM Liquid crystal display continuously shows  
actual room temperature. 

 
 To display the temperature requested,(the SET POINT) press and hold the button marked SET. On releasing this button 

the display will revert back to actual temperature. 

 
 To change the SET POINT,(I,e, the temperature requested),press and hold the SET button, and at the same                                            

time, press 

+

 or  

-

 to increase or decrease the temperature setting. The display will continue to show the SET POINT until 

the SET button is released. The display will then show actual temperature. 

 
When the TLX 7506 instructs your heating system to switch on, 
A small flame symbol appears at the bottom right of the display. This symbol will be displayed only when the thermostat is 

calling for the heating to be on. 

 

TLX 7506  Technical data 

 

Temperature range 

   5°C to 35°C In 1°C steps                      This product complies with the essential requirements of the 

                                                                                                            Following EC Directives 
 

 

 

   16°C to 35°C selectable.  

        Electro-Magnetic Compatibility Directive EMC 89/336/EC 

                                                                                                             (as amended by 91/263/EECand 92/31/EEC) 
Differential 

 

   <1°C at 4 K per Hour. 

 

        Low Voltage Directive:      

                                                                                                             LVD 73/23/EEC;96/68/EEC 
Ambient Temperature Operating 0°C to 45°C 
 
Power supply 

                 2 type AA 1.5V alkaline  

 

 

 

   Cells 

 
Switch   

 

   230V ac 2(1)A 

 
Battery life 

 

   2 years typical 

 
Wiring   

 

   For fixed wiring only 

 
Maintenance 

 

   Minimal user maintenance 

 
Radio signal range 

   30 metres typical 

 
Year 2000 compliant in accordance with BSI/DISC 2000-1 
 

In the interests of continuous product improvement, Sunvic Controls reserve the right to alter designs, specifications and materials without prior notice 
and cannot accept liability for errors. 

cc

 

SUNVIC CONTROLS Ltd 

Bellshill Road  
Uddingston 
Glasgow 
G71 6NP 
Tel: (01698 812944) Fax: (01698 813637) 
 
Technical Helpline: (01698 810945) 

Summary of Contents for TLX 7506

Page 1: ...a temperature that is reasonable for the whole house If you do have TRVs you can choose a slightly higher setting to make sure that even the coldest room is comfortable then prevent any overheating in other rooms by adjusting the TRVs Room thermostats need a free flow of air to sense the temperature so they must not be covered by curtains or blocked by furniture Nearby electric fires televisions w...

Page 2: ...ce the batteries the following procedure should be carried out The thermostat should be isolated from the mains before proceeding 1 Remove the unit from the wall plate by sliding upwards and gently pulling away from the wall Slacken the retaining screw on the unit and open by hinging upwards along the top of the unit 2 Carefully remove batteries from the battery compartment and fit two new AA alka...

Page 3: ...s been received When this happens the RED LED will start pulsing slowly and the INSTALL button can be released The RED LED will pulse for a further 3 seconds and then go off The INSTALL code has been successfully received 4 Go to the thermostat transmitter and press any key to stop the transmission The display will stop transmitting and return to normal 5 The TLX 1206 RF receiver will now only res...

Page 4: ...e display will revert back to actual temperature To change the SET POINT I e the temperature requested press and hold the SET button and at the same time press or to increase or decrease the temperature setting The display will continue to show the SET POINT until the SET button is released The display will then show actual temperature When the TLX 7506 instructs your heating system to switch on A...

Reviews: