background image

Floor Sensor

1. Test the Thermostat Floor Sensor included to make sure it has not been 

damaged in handling.  Use a digital multimeter set to the 20k

Ω

 range.  The 

resistance varies according to the temperature sensed. These are approximate 

values for reference:

Table 1 – Sensor resistances

TEMPERATURE

TYPICAL VALUES

55°F (13°C)

17 k

Ω

65°F (18°C)

13 k

Ω

75°F (24°C)

10 k

Ω

85°F (29°C)

8 k

Ω

2. Pull the floor sensor wire up the wall (or conduit) to the control location.  

Consider the following:

•  Leave about 6 to 8 inches (15 to 20 cm) of wire for connections later.
•  The sensor wire may be cut shorter if desired, but do not cut it shorter until 

the sensor is fully installed (see below). Re-strip the sensor wire ends 1/8" to 

3/16" (3 mm to 4.5 mm) long. If the ends are stripped longer than this they 

may short-circuit resulting in an Err2 code.

•  If the sensor wire is not long enough to reach the control location, it may be 

extended an additional 15 feet (4.5 m) using minimum 20 AWG 2-conductor 

unshielded wire, or an additional 50 feet (15 m) using shielded wire. When 

using shielded wire, the “shield” must be connected to the lower sensor 

terminal, nearest to Bus A. A junction box may be required by local code for 

the connection to this extension wire.

3. After the floor heating system is completely installed according to its 

instructions, secure the thick sensor tip to the floor. Consider the following: 

•  It must be located halfway between heating wires and at least 1 foot into 

the heating area.

•  Use hot-glue to secure the sensor tip and wire in place.

•  Do not cross over a heating wire.

•  Avoid placing it in an area where heating wires are spaced further apart than 

the rest of the floor, like a large gap between mats or cables.

•  Avoid placing it in an area where a heat duct or recessed light will cause 

improper measurements.

•  Try to avoid locating it where future items such as a clothes hamper or similar 

could trap heat and cause improper measurement.

Power Leads from Heating Mat or Cable

Pull the power lead wires from the floor heating system into the control location. 

Excess power lead wire may be cut off, but leave about 6 to 8 inches (15 to 20 

cm) of wire for connections.

Removing the Thermostat Front Module 

1. Remove the Screw Cover at the bottom and loosen the screw.
2. Lift the Front Module away from the Power Module.

Figure 1

Figure 2

Screw Cover

Cover Screw

Front Module

Load 1

Line 1

Line 2

Load 2

Floor Sensor

Connec

Ɵ

 on

Power 

Module

Mounting the Thermostat

1. Make sure the power supply to the circuit is turned off at the circuit breaker.
2.  Carefully press the wires back into the electrical box.

•  DO NOT use the control to push wires in, as this may cause connections to 

loosen and possible failure.

3. Use the Mounting Screws provided to secure to the electrical box and tighten 

by hand.

•  DO NOT over-tighten the screws causing the plastic to distort, as this may 

cause improper function of the thermostat.

4. Press the Front Module onto the Power Module.  Make sure both tabs at the 

top are completely engaged.

•   DO NOT install the Front Module with power applied on the Power Module, 

as this may cause improper function of the thermostat.

5. Secure the screw at the bottom and replace the Screw Cover.
•  DO NOT over-tighten the screw causing it to strip. Turn it until snug.

Wiring Connections 

(see Figure 1 and 2)

Connect the wires as shown in the diagram.  Consider the following:

•  Gently tug on the wires to make sure they are secure. For added security, overwrap 

the Wire Nut connections with electrical tape.

•  If the electrical box is metal, a short length of wire must be secured to the electrical 

box from the ground connection.

•  When connecting the Floor Sensor to the Sensor terminals, it does not matter 

which wire goes into which terminal.

•  The Bus A and B terminals are used to communicate with a SunStat Relay II.  Please 

read and follow the instructions provided with the SunStat Relay II for further details.

Reviews: