Suntherm AL LED 150 Instruction Manual Download Page 11

11

DISMOUNTING

1. Disconnect the appliance from the power by 

switching off the circuit breaker.

6. Dismount the mounting frame by unscrewing the 

four screws.

5. Hinge the panel out of the mounting frame.

2. Push the heating panel gently towards the ceiling 

and release the spring clip ridge from the recess of the 

panel using a flat tip screwdriver or forceps.

3. Repeat the procedure with the second spring clip 

and then swing the heating panel down.

4. Leave the panel suspended in the mounting frame 

hinges. Disconnect the connecting cables from the 

terminal block.

230 V

Summary of Contents for AL LED 150

Page 1: ...INFRAROT HEIZPANEEL INFRARED HEATING PANEL SUNTHERM LED BEDIENUNGSANLEITUNG seite 2 6 INSTRUCTION MANUAL page 7 11...

Page 2: ...g besch digt ist muss sie vom Hersteller seinem Servicetechniker oder einer entsprechend qualifizierten Person ausgetauscht werden um eine Gefahr zu vermeiden Das Heizpaneel ist f r die Installation i...

Page 3: ...zur Anbringung an der Wand geliefert Wir empfehlen dass jeweils zwei Personen die Installation durchf hren Bei der Installation muss das Netzkabel vom Netz getrennt sein gem Kapitel Montage Das Heizpa...

Page 4: ...schwarz Farbige Kennzeichnung der Leiter Braun L Phase Blau N Neutralleiter Gelb PE Schutzleiter Das Paneel darf nicht unmittelbar ber einer Steckdose angebracht werden Bei einer Besch digung des Vers...

Page 5: ...getrennt wurde und schlie en Sie die beiden Anschlusskabel ber die Anschlussleiste ans Stromnetz an 4 Bringen Sie den Rahmen an und befestigen Sie ihn mit den beiliegenden Schrauben 2 Bringen Sie den...

Page 6: ...n Sie das Paneel an den Scharnieren des H ngerahmens h ngen Trennen Sie die beiden Anschlusskabel von der Anschlussleiste 2 Dr cken Sie das Heizpaneel leicht in Richtung Decke und l sen Sie mit einem...

Page 7: ...ower connection is damaged it must be replaced by the manufacturer the manufacturer s service technician or a similarly qualified individual to prevent any risks The heating panel is designed to be in...

Page 8: ...a team of two people The installation must be carried out with the connection cables disconnected from the power source as described in the Assembly chapter The heating panel may be installed on surfa...

Page 9: ...heating panels are designed to be mounted onto ceilings at a height of at least 1 8 m above floor level and at a distance of at least 0 2 m from vertical structures There must be at least 0 5 m of uno...

Page 10: ...re that the power is switched off then connect both light black cable and heating white cable of the panel to the power mains using a terminal block 4 Mount the frame by screwing it into the ceiling w...

Page 11: ...e mounting frame 2 Push the heating panel gently towards the ceiling and release the spring clip ridge from the recess of the panel using a flat tip screwdriver or forceps 3 Repeat the procedure with...

Page 12: ...office suntherm austria at www suntherm at MADE IN EU Compliant...

Reviews: