15
EN
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
Error symbol
appears in right upper part of
display. Flashing and beeping error symbol
mean error or fault in boiler operation. Use
“
Enter
“ button to move to next screen with
error notification in lower left part of display. When
the issue is corrected, error notification can be
deleted. When disconnect the boiler from electrical
supply for few seconds and then switch on it again,
boiler goes back to normal operation (error
notification is deleted).
S
Cleaning system of exhaust gas tubes is
activated.
A
Ash cleaning system is activated.
Factory setting - Alarms
BB ALARM
Reverse fire Alarm (when the
thermostat contact RB input is
open)
SENSOR E1
Boiler Temperature Sensor is
missing (input B)
SENSOR E2
Boiler Temperature Sensor Short
circuit ( input B)
IGNITION FAIL
Failure ignition
BURNOUT
Exhaust gas temparature is too
low in Operation mode. If the
exhaust gases temperature drops
below 85°C the boiler will shift into
extinguishing mode.
DHW E1
Water Heater Temperature Sensor
is missing (input WH)
DHW E2
Water Heater Temperature Sensor
Short circuit (input WH)
Cleanup
This alarm appears when gas
temperature rises above 180°C
TE Alarm
This alarm appears when gas
temperature rises above 220°С
TE E1
Temperature sensor of exhaust
gases is missing
TE E2
Short circuit of temperature sensor
of exhaust gases
CH btm E1
Temperature sensor of lower part
of buffer tank is missing (when in
chosen scheme with buffer tank)
CH btm E2
Short circuit of temperature sensor
of lower part of buffer tank (when
in chosen scheme with buffer tank)
CH top E1
Temperature sensor of upper part
of buffer tank is missing (when in
chosen scheme with buffer tank)
CH top E2
Short circuit of temperature sensor
of upper part of buffer tank (when
in chosen scheme with buffer tank)
When restarting the controller alarm is deactivated.
Notify the authorized installer/ service to
be performed immediately inspection of
the boiler and heating installation.
”С” symbol means that the
motor of automatic
cleaning
system
is activated.
The symbol “
T
” indicates
that a room thermostat is
connected to the controller
of the burner (the boiler).
In “
CH Priority
” mode the room thermostat controls
the burner by starting and stopping it. In “
DHW
Priority
” mode the room thermostat controls the
heating installation pump by starting it when the
temperature of the domestic hot water has reached
the maximum preset temperature. In “
Parallel
Pumps
” mode the room thermostat controls the
heating installation pump regardless of the
temperature of domestic hot water. In “
Summer
Mode
” the room thermostat is disabled.
Lights for operating:
-
Pump heating system
-
Pump Domestic hot water
.
10.2. User menu
10.2.1. Initial (start-up screen) „Standby“
The burner is in standby
mode.
The display shows:
Temperature in the boiler
(23 degrees), time, and
by pressing the
Enter
button you can browse the quick menu (bottom left)
where the following read-only data is displayed:
Maximum set temperature t=85
o
C
,
temperature
of domestic hot water
where such heating circuit
is connected);
Light intensity in the burner
;
Burner
status
(detected errors, if any);
Date
.
Error message. If there is an
emergency in the operation of
the facility for any reason will be displayed as an
error.
Мaximum
set
boiler
temperature.
Current date.
Parameter
t
DHW
indicates
temperature of domestic hot water inside the water
heater.
Summary of Contents for Burnit PelleBurn 15
Page 58: ...58 Diagrams Schemes Schémas 1 3 2 4 5 ...
Page 59: ...59 Diagrams Schemes Schémas 5 1 6 45o ...
Page 61: ...61 Diagrams Schemes Schémas 9 10 CHPUMP RT room thermostat TTOP TBOTTOM CHPUMP ...
Page 65: ...65 Diagrams Schemes Schémas 23 23 1 U H D V W1 Z O Т F P M W2 D K W F P L J B L A N B ...
Page 66: ...66 Diagrams Schemes Schémas 24 25 26 27 ...
Page 67: ......