TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
10
5) Service booklet and Warranty card
If any of the above items are missing,
contact your supplier.
6. STORAGE OF PELLET BURNER
Pell ECO burners shall be stored in dry
and well ventillated spaces, free from any
gases, liquids, acids and oil vapours that
may damage the burner. Storing burner
and auger in spaces with fertilizers,
chlorinated lime, acids, chemicals, ect.
is not allowed. Recommended storage
temperature shall be from +5°С tо +40°С.
Recommended relative humidity -below
70%. When stored, the devices shall not
have direct contact with the ground,
placed on pallets, maximum two tiers and
in their original packaging. The storage
period is not more than 2 years from date
of manufacture. It is recommended that
every burner is tested before installation.
Quality and safety of the burner must
be confirmed by a test mentioned in the
warranty card.
7. MOUNTING OF THE BURNER
Recommended boiler chamber sizes for
mounting of Pell ECO pellet burner:
Diagram 4. Mounting of Pell ECO pellet
burner to boiler combustion chamber
Mounting, installation and setup
of burner should be carried out by
authorized technician. Installer
shall advise the user of the
installation minimum clearances
to combustible materials and
liquids.
Table 3
Pell 35 ECO
Pell 55 ECO
А
350
350
B
450
450
C
450
550
7.1. Pellet burner connection to the fuel
hopper and pellet auger
Take the feeder chute flexible hose (from
the auger set). Using a bracket, clamp
one end of the hose onto the motor-end
outlet of the pellet auger.
- Remember – pellet auger must be
installed at 45° angle to the ground
horizontal surface.
- Fill the hopper with fuel (see table 2 for
parameters of the fuel types used)
- Plug the power cord of the pellet auger
into the indicated Schuko-type burner
socket on the left side of the burner
housing.
Diagram 5. Mounting the pellet burner Pell
ECO to WBS boiler
1.
WBS boiler;
4.
Auger;
2.
Pellet burner Pell ECO;
5.
Fuel hopper.
3.
Auger flexible pipe;