SunSun CUP-807 Operation Manual Download Page 3

Introduction

Thank you for purchasing this quality product.

 To minimize the risk of injury we urge that our cli-

ents take some basic safety precautions when using this device. Please read the operation in-
structions carefully and make sure you have understood its content.

Keep these operation instructions safe.

Installation

1. Remove all parts from the box to see if all parts are present.
2. Before installation check that the UV bulb inside is installed correctly.

Remove the body by squeezing both pressure points on the side of the body and pulling
the motor and body part.

Visually check if the UV bulb is still correctly inserted in its connection point. If the bulb is
lose, unscrew the screw and twist the screw nut counter-clockwise to release the quartz
glass (leave the clear O-ring located underneath the quartz glass in place).

Re-insert the UV bulb.

Replace the quartz glass ensuring the O-Ring at the quartz base is present.

Re-attach the screw nut and screw, replace the body.

3. Attach the suction cups to the base place, attach the base plate to the back of the item.
4. Attach the venturi outlet to the top of the unit.
5. Place the item inside of your fish tank with the suction cups against the glass in your preferred

location.

Please note:

 Ensure this location allows the item to be fully submerged at all the times.

6. Turn the UV on by sliding the front on/off switch to the left.
7. Position the venturi outlet above the water level to allow air to pass through the venturi outlet

valve.

8. Plug your item into your main power socket.

Maintenance

Decide on how regularly you would like to maintain this item; that depends on your water
volume and how many fish you are keeping. The best time to clean your filter is when com -
pleting a 10 % water change as you can use the aquarium water you are discarding to clean
all the parts of this item.

When cleaning this item, you should wash the following parts using the water from your aquar-
ium:

№ 5

Impeller

№ 4

Adjustable outlet

№ 14–16 Filter foam, filter body and body cover

№ 3

Media provided in media basket

Replacement of the UV lamp tube

Please note the UV bulb should be replaced every 6 months ever if the light is still showing,
doing this will ensure the UV operates effectively at all times.

Check that your UV light tube is working at any time by visually checking the UV light indicator
on the front of the item. This will light up tube if the UV light tube is working. Proceed as fol -
lows:

Unplug the item at the mains and remove the plug from the socket.

Remove the item from the aquarium.

Remove the body by squeezing both pressure points on the side of the body and pulling
the motor and body apart.

Unscrew the screw and twist the screw nut counter-clockwise to release the quartz (leave
the clear O-Ring located underneath the quartz glass in place).

© by WilTec Wildanger Technik GmbH 

Item 50985, 50986 

Page 3 

http://www.WilTec.de
http://www.aoyue.eu

 

12 2020

-1

http://www.teichtip.de

Summary of Contents for CUP-807

Page 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insi...

Page 2: ...ages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pic...

Page 3: ...off switch to the left 7 Position the venturi outlet above the water level to allow air to pass through the venturi outlet valve 8 Plug your item into your main power socket Maintenance Decide on how...

Page 4: ...ly Do not attempt to modify this unit in any way and only use the recommended parts for re placement All connections must be earthed Do not connect any voltage other than that stated Do not place the...

Page 5: ...7 CUP 809 Voltage 220 240 V 50 Hz 220 240 V 50 Hz Total capacity W 10 10 UV lamp W 7 9 Max aquarium capacity 500 720 Flow rate h 700 700 by WilTec Wildanger Technik GmbH Item 50985 50986 Page 5 http w...

Page 6: ...out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correc...

Page 7: ...s Richtlinien bereinstimmt This appliance is in conformity with the following European directives Cet appareil est conforme aux directives europ ennes 2014 35 EU Es ist nach folgenden harmonisierten N...

Page 8: ...tlinien bereinstimmt This appliance is in conformity with the following European directives Cet appareil est conforme aux directives europ ennes 2014 30 EU Es ist nach folgenden harmonisierten Normen...

Reviews: