UV Sterilizer Instructions 
 
Cleaning and Changing Part: 

1.

 

Unplug the power and pour out the water. 

2.

 

Pull out the motor from the filter body. 

3.

 

Clean the impeller and change UV bulb if necessary. 

4.

 

Take out the quartz tube and clean the surface. 

5.

 

Check if the quartz tube and O-ring are in good condition (change if necessary). 

6.

 

Assemble the parts back together. 

 
Product Spec

 

Model 

Flow Rate 

UV Wattage 

Suitable 
Aquarium Size 

Product Dimension 

CBG-500 

500L/h 
(132GPH) 

5W 

38~115L 

(10-

30GAL) 

192x110.5x165mm 

CBG-800 

800L/h 
(211GPH) 

5W 

75~190L 

(20-

50GAL) 

229x127.5x179mm 

 
Troubleshooting

 

Problem 

Cause 

Solution 

Dirty Water 

Beneficial bacteria are not 

established in the new filter.   

Dose some bacteria into the 

filter and tank (learn more 

about the Nitrogen Cycle in 

Aquarium Online). 

Not the right size 

Upgrade to a larger filter 

Too many livestock 

For reference only: 1 inch of 
fish per gallon of tank water 

Dirty filter pads 

Clean the filter pads 

Dirty quartz tube 

Clean the quartz tube 

Water is extremely dirty 

Perform a 50% water change 

The UV Light Is Not On 

Filter is not plug into power  Plug the filter to power outlet 

UV bulb burn out 

Replace 5W UV bulb 

The On/Off switch in Off 

position 

Push the switch to the On 

position 

No Water Coming Out 

No water in filter body 

Put tank water in filter body 

Filter not plugged into power  Plug filter to the power outlet 

Intake cover clogged 

Clean intake cover 

 
Replacement Parts: 

1.

 

UV bulb (suggest changing after 8000 hours of usage) 

2.

 

Filter pads and media   

3.

 

O-ring 

 
 