background image

Ceramic shaft, wear and rust resistance

Long service life, no copper element

Multistage outlet, suitable for a variety of pipe diameter connection

Electric drive, safe and stable

External aluminum alloy radiator of the controller can dispatch well heat well

With anti-blocking and anti-idling function (cuts off power immediately and automatically if im-
peller is blocked, immediately and automatically cuts off power if pump is idling)

With alarm function, warns you of various abnormal problems

Installation

1. Notify your dealer immediately if there are external damages.
2. Compare the voltage and frequency of your electrical circuit with the data on the model plate,

these data must correspond.

3. Connect the pipeline if needed. (Attention: The piping system must not contain bubbles.) Hose

connection diagram is as follows:

This product disposes of a variety of outlets, you can select one according to the size. Loosen the nut
in clockwise direction, connect the hose, tighten the nut in anti-clockwise direction.

4.

Attention:

 the pump must be installed below the water level 20 cm at least, the water surface

must be stale and horizontal.

5. Do not place the pump directly in muddy pond floors, place it on a raised surface.
6. Connect the pump with the controller of four core wire (Pic 1), lock the nut as shown in Pic 2.

© by WilTec Wildanger Technik GmbH 

Item 50982, 51192

Page 4 

http://www.WilTec.de
http://www.aoyue.eu

 

03 2021

-1

http://www.teichtip.de

Summary of Contents for 50982

Page 1: ...llow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can dif...

Page 2: ...ages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pic...

Page 3: ...ransport any liquids other than water Attention The pump will automatically stop working if overloaded or running without water The controller is not water proof put it in a dry and well ventilated pl...

Page 4: ...ectrical circuit with the data on the model plate these data must correspond 3 Connect the pipeline if needed Attention The piping system must not contain bubbles Hose connection diagram is as follows...

Page 5: ...supply Gear level Power W Flow rate h Max lift ing head m 50982 CET 8000 220 240 V 50 Hz SP01 18 3500 1 6 SP02 23 4000 1 9 SP03 28 4600 2 3 SP04 35 5000 2 7 SP05 42 5400 0 1 SP06 51 5800 3 5 SP07 60 6...

Page 6: ...n the pump will power off until re connect the power Meanwhile the alarm buzzer will sound The pump will cut off power automatically and immediately if the impeller is blocked and the alarm buzzer wil...

Page 7: ...er in the pump should be discharged immediately in order to prevent a freezing damage Troubleshooting Problem Cause Solution Pump does not run No power supply Connect the power Burning machine Change...

Page 8: ...e 9 Motor with cable 3 Outlet 10 Rear cover 4 Seal circle 11 Handle 5 Impeller cover 12 Rubber foot 6 Rotor set 13 Gear box with cable 7 O Ring by WilTec Wildanger Technik GmbH Item 50982 51192 Page 8...

Page 9: ...out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correc...

Reviews: