PART NO. 690963 REV: A-01
31
Problem
Possible Solution(s)
Lift does not operate with manual switch on RC box
Check power on RC box is on
Check battery voltage
Check all wires are connected to Solenoids on pump
Lift does not operate with key fob transmitter buttons.
Check that lift operates with manual switches on RC box (see above)
Re-program key fob transmitter per instructions in RC manual
Check battery voltage in key fob transmitter
Key fob transmitter has limited range
Check battery voltage in key fob transmitter
Hold transmitter in different location (over head, or different location in boat)
Proximity to cell phone towers, power lines and other electromagnetic interfer-
ence can also reduce range.
Battery does not keep a charge
Check battery fluid level
Verify charger and/or solar connector properly plugged in
Verify solar panel getting direct sun light
Cannot or difficult to connect hoses
Depressurize system via RC box
Use wrench to connect QD’s
Check for any debris in hose threads
Fluid found in bottom of Power Pack
On a new lift, sometimes air in the system expands and causes fluid to overflow
Check fluid level after installation is complete and all air is purged from system
Check for leaks. Tighten hose fittings or gaskets as necessary.
Battery terminal becomes hot
Check battery cable and terminals are clean and tight on battery terminal
Troubleshooting the SunLift SLX