Mounting Option 3 - Bolt to table
•
Remove the clamp and position the base against the table .
•
Trace drill holes with a pen or marker .
•
Drill 1/4’ holes in the tabletop .
•
Run screws through the base into the drilled holes .
MICROSCOPE SETUP
•
Remove the microscope from the box and place it into the round clamp
at the top of the arm .
•
Tighten the screw on the round clamp to secure the microscope to the
arm .
•
Install the rubber eyepiece covers onto the microscope lenses .
•
Insert the welding stylus into the stylus holder under the microscope
then tighten the stylus holder knob .
•
Ensure the microscope cable is plugged into the RJ45 port on the
microscope (the bottom of the microscope head) .
•
Ensure the microscope cable is plugged into the “Shutter” port on the
back of the power supply .
*Orion RJ45 ports are not compatible with any other RJ45 ports . Connecting
them to other devices may damage the welder and/or the other devices .