2.2.2.4 Dry contacts and indicator lights

This product contains 3 dry contacts and 3 groups of 6 LED indicators.

Function

NO.1: voltage protection

NO.2: current protection

NO.3: temperature protection

Normal operation of the battery pack is 

turned on, sleep/stop is turned off.

Fault/alarm: red light flashes

.

Remark

-

E22: Module communication abnormal level 2 alarm

E51: Module overvoltage level 1 alarm

E52: Module overvoltage level 2 alarm

E61: Module undervoltage level 1 alarm

E62: Module undervoltage level 2 alarm

E71: Module charging overcurrent level 1 alarm

E72: Module charging overcurrent level 2 alarm

E81: Module discharge overcurrent level 1 alarm

E82: Module discharge overcurrent level 2 alarm

E83: Module discharge load short circuit (serious)

E92: Single cell overvoltage level 2 alarm

E101: Single cell undervoltage level 1 alarm

E102: Single cell undervoltage level 2 alarm

E111: Module high temperature level 1 alarm

E112: Module high temperature level 2 alarm

E121: Module low temperature level 1 alarm

E122: Module low temperature level 2 alarm

The dry contact can be normally 

open or normally closed.

Item

Dry contact

Operating

indicator

Alarm 

indicator

Item

RS485/CAN

RS232

Number

1

2

3

4

5

6

7

8

1

2

3

4

5

6

Signal

CAN-H

CAN-L

-

485-A

485-B

-

GND

GND

232-RXD

232-TXD

GND

GND

-

-

Schematic diagram

Summary of Contents for SLPO48-100

Page 1: ...LITHIUM BATTERY PACK USER MANUAL MODEL SLPO48 100 Please read this manual before using the battery pack Please keep this manual properly after reading...

Page 2: ...scharging 20 55 C 1month 20 45 C 3 months 10 45 C 6 months 0 25 C humidity 45 90 RH The battery should be cycled every three months After 6000 cycles at 25 C 50A charge and discharge 80 DOD recoverabl...

Page 3: ...tonepower com 2 Structural characteristics and interface definition A Basic structure 2mm sheet metal box structure and rack B Installation method screw lock C Surface coating add spray paint 2 1 Over...

Page 4: ...POWER switch until the red light turns on first the green light turns on but the switch shouldn t be released The system self checks when the red light is flashing about 10S After that the battery wi...

Page 5: ...and battery pack status OK or abnormal code On the next page you can view the maximum and minimum voltage maximum and minimum tem perature of the battery User can view the voltage of each cell on pag...

Page 6: ...rm E51 Module overvoltage level 1 alarm E52 Module overvoltage level 2 alarm E61 Module undervoltage level 1 alarm E62 Module undervoltage level 2 alarm E71 Module charging overcurrent level 1 alarm E...

Page 7: ...ormal operation temp Tpmin Tpmax C 10 Tpmin 35 20 Tpmin 15 Tpmin 20 75 Tpmax 85 Tpmax 85 60 Tpmax 65 Tpmax 65 13 15 65 75 57 60 Code E121 E122 E111 E112 E111 E112 Temp protection recovery value C dela...

Page 8: ...delay 5S Dry contact output Dry contact 1 action Dry contact 1 action Remark No code displayed Code Charge E71 Discharge E81 Charge E72 Discharge E82 E83 75 75 Imax 105 Imax 105 Imax 200 within 1mS 7...

Page 9: ...nsistent with the displayed current If the difference is large the BMS current may be inaccurate and needs to be replaced by a professional or authorized person Check whether the load of the battery i...

Page 10: ...at the charging equipment performs charging according to the voltage and current regulationsent by the BMS to ensure that the battery will not be overcharged 5 Check the connection of the battery pack...

Page 11: ...onnect the whole system in series or parallel operation with other batteries These operations may cause personal injury or property lose If necessary please contact the relevant technical depart ment...

Reviews: