③
Insert the table and fasten the bolts and the clamps.
[CAUTION]
The table should not be higher than the upper side of the needle plate by 0.5mm for board frame
work. If the height difference is over 0.5mm, unfasten the table support bolts, adjust the height, and
fasten the bolts back.
Clamp
Clamp
Clamp
Table support
Bolts
height difference
if gap is larger
than 0.5mm
Table support
Bolts