Install your machine in an appropriate environment and with adequate electrical supply. Failure to follow the
directions may result in machine malfunction.
2-1) ENVIRONMENT
1) Temperature:
①
0
∼
40
℃
(32
∼
104°F) when the machine is in operation
② -
25
∼
55
℃
(
-
13
∼
131°F) when the machine is not in operation
2) Humidity: 45
∼
90% (relative)
3) Grounding: Ensure the electricity is properly grounded.
4) Close any doors and windows near the machine to prevent direct light, dust, and humidity.
5) Foundation under the machine must be a sufficiently strong and flat concrete to support the weight of the
machine.
2-2) ELECTRICITY
Check if the input voltage of the machine is in the right range of the voltage supply before installing or operating
the machine. The voltage required is as follows:
1) Input voltage (to be adjusted when installing): 100V, 110V, 120V, 200V, 220V, 240V
2) Allowed range of voltage: within
±
10% of the voltage set
3) Electric capacity and voltage consumption: 640VA 440W
4) Insulation resistance: over 10M ohms (measured with 500V insulation tester)
INSTALLATION AND MACHINE ASSEMBLY
CHAPTER
2
WARNING
DANGER
Properly ground the machine to avoid the possibility of electric shock. Use three-wire grounding
(grounding resistance below 100 ohms).
Check the voltage supply where the machine will be installed.
Install the cable away from the operator s work space to prevent accident or injury.
[CAUTION]
Do NOT let moisture drops on the machine.
Provide air conditioning to control humidity and to prevent dust and corrosion.