28
④
After adjusting the stitch length, fix it firmly by tightening the feed rocker link shaft screw
ⓓ
then fill the left screw
ⓒ
of the bed.
(The left screw
ⓒ
of the bed is to prevent oil leakage so tighten it firmly.)
⑤
After adjusting the needle guard(back)
ⓑ
to the proper position and tighten the needle guard(back) clamp screw
ⓐ
firmly.
Reset the needle guard(back)ⓑ to prevent the breakdown of parts after adjusting the stitch
length.
Caution
[ Figure 37 ]
[ Figure 38 ]
Adjust the main feed all the time after adjusting the differential feed.
Caution
9) DIFFERENTIAL FEED MODIFICATION
To adjust the differential feed dog, rotate the differential feed
operating lever
ⓐ
to the left or the right.
If the differential feed operating lever
ⓐ
is between the 4 and 5,
the momentums of the main feed dog and the differential feed
dog will be the same.
For the forward differential, turn the differential feed operating
lever
ⓐ
to the scale of 9. For the reverse differential, turn the
differential feed operating lever
ⓐ
to the scale of 1.
Tip) The differential operating lever stopper screwⓑ can be used
when fixing the differential feed operating leverⓐ or retaining the
adjustment range of the differential motion.
[ Figure 39 ]
ⓐ
ⓑ
ⓒ
ⓓ
ⓐ
ⓑ
ⓑ
Forward
Reverse
increasing
decreasing
Check the OFF-status condition of a power switch before adjusting the differential feed
adjustment.
Warning