11
2) Lubrication
(1) Installing Magnetic Chip Remover
A. Attach the magnetic chip remover that is in the
accessory box to the oil pump inside the bed.
(See Fig. 2)
※
Do not use the magnet for other purposes. Use of the
sewing machine without the magnet may cause
malfunction and has a bearing on the machine
’
s
durability.
[Fig.2]
Magnet
Oil pump
(2) Lubricating the oil fan
A. Fill the lubricant up to the
“
HIGH
”
mark. (See
Fig.3.)
B. The lubricant must be SUNSTAR
’
s oil provided
exclusively for industrial sewing machines or
SHELL
’
s Tellus C10.
C. If the oil in use is down to the
“
LOW
”
mark, fill in
to
“
HIGH
”
immediately.
D. Once every two weeks is deemed the appropriate
interval for oil refills.
3) Belt Tension Adjustment
Sufficient loosening of the fixed nuts
①
,
②
after motor
③
installation would create tension to the belt
④
. Tighten the
fixed nut
①
first and then tighten the fixed nut
②
to an
unmovable position. (See Fig. 4)
[Fig.3]
[Fig.4]